Search Results - "Vladimir Pakhaliuk"
-
1
Predictive Estimates of Short-Term and Long-Term Results for Regenerative Rehabilitation of Local Articular Cartilage Defects in Synovial Joints
Published in Lubricants (01-03-2023)“…Osteoarthritis is a serious disease of the synovial joints, accompanied by a degenerative lesion of the articular cartilage, often resulting in disability for…”
Get full text
Journal Article -
2
Is It Possible to Create an “Ideal Endoprosthesis” for an “Ideal Total Hip Replacement”?
Published in Prosthesis (Basel, Switzerland) (01-10-2023)“…Since the end of the 19th and the beginning of the 20th centuries, technological equipment, implant designs (endoprosthesis) and the surgical technique of…”
Get full text
Journal Article -
3
In silico evaluation of the mechanical stimulation effect on the regenerative rehabilitation for the articular cartilage local defects
Published in Frontiers in medicine (07-03-2023)“…Osteoarthritis is one of the most severe diseases of the human musculoskeletal system, and therefore, for many years, special attention has been paid to the…”
Get full text
Journal Article -
4
Improving the Endoprosthesis Design and the Postoperative Therapy as a Means of Reducing Complications Risks after Total Hip Arthroplasty
Published in Lubricants (01-03-2022)“…One of the most high-tech, efficient and reliable surgical procedures is Total Hip Arthroplasty (THA). Due to the increase in average life expectancy, it is…”
Get full text
Journal Article -
5
Current Trends in Improving of Artificial Joints Design and Technologies for Their Arthroplasty
Published in Frontiers in mechanical engineering (05-02-2020)“…There is a global tendency to rejuvenate joint diseases, and serious diseases such as arthrosis and arthritis develop in 90% of people over 55 years of age…”
Get full text
Journal Article -
6
FAST USER ACTIVITY PHASE RECOGNITION FOR THE SAFETY OF TRANSFEMORAL PROSTHESIS CONTROL
Published in Facta Universitatis. Series: Mechanical Engineering (01-04-2020)“…In the process of creating powered transfemoral prostheses, one of the most important tasks is the provision of the user safety while walking. Experience shows…”
Get full text
Journal Article -
7
SIMULATION OF WEAR IN A SPHERICAL JOINT WITH A POLYMERIC COMPONENT OF THE TOTAL HIP REPLACEMENT CONSIDERING ACTIVITIES OF DAILY LIVING
Published in Facta Universitatis. Series: Mechanical Engineering (01-04-2018)“…The present study assesses the impact of the main typical activities of patients' daily living (ADL) after total hip arthroplasty (THA) on the wear parameters…”
Get full text
Journal Article -
8
Reducing the Wear of the UHMWPE Used in the Total Hip Replacement after Low-Pressure Plasma Treatment
Published in Journal of applied and computational mechanics (01-07-2022)“…This paper discusses the problem of evaluating the microhardness gradient effect on surface wear of an ultra-high molecular weight polyethylene (UHMWPE) films…”
Get full text
Journal Article -
9
Effect of Graphene Oxide and Plasma Treatment on Tribological Characteristics of Ultra-High Molecular Weight Polyethylene
Published in Tribology in industry (01-06-2023)“…A technology has been developed for preparing a suspension and deposition of a coating to the surface of ultra-high molecular weight polyethylene (UHMWPE)…”
Get full text
Journal Article -
10
Synovial Joints. Tribology, Regeneration, Regenerative Rehabilitation and Arthroplasty
Published in Lubricants (01-02-2021)“…Synovial joints are unique biological tribosystems that allow a person to perform a wide range of movements with minimal energy consumption. In recent years,…”
Get full text
Journal Article -
11
MODIFYING AND EXPANDING THE SIMULATION OF WEAR IN THE SPHERICAL JOINT WITH A POLYMERIC COMPONENT OF THE TOTAL HIP PROSTHESIS
Published in Facta Universitatis. Series: Mechanical Engineering (01-12-2016)“…The existing model of wear, based on the classical Archard equation, in the spherical joint of a total hip prosthesis comprising an acetabular cup of…”
Get full text
Journal Article -
12
BIOSIMILAR ARTIFICIAL KNEE FOR TRANSFEMORAL PROSTHESES AND EXOSKELETONS
Published in Facta Universitatis. Series: Mechanical Engineering (01-12-2016)“…Artificial knees play an important role in transfemoral prostheses, lower extremity exoskeletons and walking robots. Their designs must provide natural…”
Get full text
Journal Article -
13
IN SILICO ANALYSIS OF AN ARTICULAR CARTILAGE REGENERATIVE REHABILITATION UNDER CONDITIONS OF MESENCHYMAL STEM CELLS IMPLANTATION AND THEIR MECHANICAL STIMULATION
Published in Facta Universitatis. Series: Mechanical Engineering (01-12-2024)“…One of the most important tasks of modern medicine is the development of effective technologies for the treatment of joint diseases caused by damage to the…”
Get full text
Journal Article -
14
Universal Mechatronic Test Bench-Gait Simulator for Testing Lower Limb Prostheses
Published in 2022 IEEE 23rd International Conference of Young Professionals in Electron Devices and Materials (EDM) (30-06-2022)“…This article presents a new design of a test bench-gait simulator for testing lower limb prostheses and their modules based on the Gough-Stewart platform with…”
Get full text
Conference Proceeding -
15
ONE-DIMENSIONAL BIOLOGICAL MODEL OF SYNOVIAL JOINTS REGENERATIVE REHABILITATION IN OSTEOARTHRITIS
Published in Facta Universitatis. Series: Mechanical Engineering (01-08-2022)“…This work is devoted to the study of a one-dimensional phenomenological model of a focal defect regenerative rehabilitation in the articular cartilage. The…”
Get full text
Journal Article -
16
Evaluating the Impact and Norming the Parameters of Partially Regular Texture on the Surface of the Articulating Ball Head in a Total Hip Joint Prosthesis
Published in Tribology online (2016)“…The theoretical study and evaluation of stress-strain condition of the friction pair's surfaces of total hip joint prosthesis with partially regular texture on…”
Get full text
Journal Article -
17
THE CERAMIC MODULAR HEAD IMPROVEMENT IN THE DESIGN OF A TOTAL HIP REPLACEMENT
Published in Facta Universitatis. Series: Mechanical Engineering (01-04-2021)“…For the first time, a design of a modular ceramic ball head of a total hip joint replacement (THR) friction pair has been developed, which has the properties…”
Get full text
Journal Article