  1. 1

    Analytical tools to assess the voltage stability of induction-based distributed generators by Grilo, A.P., Meira, P.C.M., Vieira, J.C.M., Freitas, W., Bansal, R.C.

    “…► A method is presented to analyse the steady-state behaviour of induction generators. ► The method can be used to identify voltage stability issues of…”
    Get full text
    Journal Article
  2. 2

    Enhanced voltage relay for AC microgrid protection by Santos, G.P., Tsutsumi, A., Vieira, J.C.M.

    Published in Electric power systems research (01-07-2023)
    “…•Voltage relays showed high dependability and are promising for microgrid protection.•The enhanced method efficiently improved the reliability of voltage-based…”
    Get full text
    Journal Article
  3. 3

    Design of protection schemes for multi-terminal HVDC systems by Blond, S. Le, Bertho, R., Coury, D.V., Vieira, J.C.M.

    Published in Renewable & sustainable energy reviews (01-04-2016)
    “…Multi-terminal HVDC is an important new technology for bulk power transfer from large sources of remote renewables to large load centers. Recently MTDC grids…”
    Get full text
    Journal Article
  4. 4

    High Impedance Fault detection based on harmonic energy variation via S-transform by Lopes, G.N., Menezes, T.S., Santos, G.G., Trondoli, L.H.P.C., Vieira, J.C.M.

    “…Successfully detecting High Impedance Faults (HIFs) is a challenge for distribution systems’ protection specialists due to the random behavior and low…”
    Get full text
    Journal Article
  5. 5

    Reliable high impedance fault detection method based on the roughness of the neutral current in active distribution systems by Lopes, G.N., Menezes, T.S., Vieira, J.C.M.

    “…Detecting High Impedance Faults (HIFs) in Distribution Systems (DSs) still requires effective solutions. HIFs can cause damage, such as shock hazards and…”
    Get full text
    Journal Article
  6. 6

    Analysis of the global second-order effects on irregular reinforced concrete structures using the natural period of vibration by LEITÃO, F. F., SIQUEIRA, G. H., VIEIRA JR, L. C. M., ALMEIDA, S. J. C.

    Published in Revista IBRACON de estruturas e materiais (01-04-2019)
    “…Abstract The χT parameter, a simplified method recently presented, allows to estimate the global second-order effects on reinforced concrete frames using the…”
    Get full text
    Journal Article
  7. 7

    A new artificial neural network based method for islanding detection of distributed generators by Merlin, V.L., Santos, R.C., Grilo, A.P., Vieira, J.C.M., Coury, D.V., Oleskovicz, M.

    “…•This paper presents an artificial neural network based method for islanding detection.•The algorithm depends only on the voltage samples measured at the DG…”
    Get full text
    Journal Article
  8. 8

    Configurable stochastic model for high impedance faults simulations in electrical distribution systems by Trondoli, L.H.P.C., Lopes, G.N., Vieira, J.C.M.

    Published in Electric power systems research (01-04-2022)
    “…•This paper proposes a fully configurable new high impedance fault model.•The proposed model generates random signals, keeping the HIF characteristics.•It…”
    Get full text
    Journal Article
  9. 9

    Power Quality Monitor Allocation Based on Singular Value Decomposition and Genetic Algorithm by Breda, J. F. D., Vieira, J. C. M., Oleskovicz, M.

    “…This paper proposed a novel method for allocating power quality meters with the main objective of ensuring a completely observable power distribution system…”
    Get full text
    Journal Article
  10. 10

    Utility Harmonic Impedance Measurement Based on Data Selection by Jin Hui, Freitas, W., Vieira, J. C. M., Honggeng Yang, Yamei Liu

    Published in IEEE transactions on power delivery (01-10-2012)
    “…Determination of the utility harmonic impedance based on measurements is a significant task for utility power-quality improvement and management. Compared to…”
    Get full text
    Journal Article
  11. 11

    Investigation on Voltage Sags Caused by DG Anti-Islanding Protection by Trindade, F. C. L., do Nascimento, Klaus V., Vieira, J. C. M.

    Published in IEEE transactions on power delivery (01-04-2013)
    “…This paper investigates the voltage sag caused by distributed generation anti-islanding protection. This is a new power-quality concern associated with…”
    Get full text
    Journal Article
  12. 12

    Comparative analysis between synchronous and induction machines for distributed generation applications by Freitas, W., Vieira, J.C.M., Morelato, A., da Silva, L.C.P., da Costa, V.F., Lemos, F.A.B.

    Published in IEEE transactions on power systems (01-02-2006)
    “…This paper presents a detailed comparative analysis between synchronous and induction machines for distributed generation applications. The impacts of these…”
    Get full text
    Journal Article
  13. 13

    Nondetection Index of Anti-Islanding Passive Protection of Synchronous Distributed Generators by Salles, D., Freitas, W., Vieira, J. C. M., Xu, W.

    Published in IEEE transactions on power delivery (01-07-2012)
    “…Synchronous distributed generators are prone to operate islanded after contingencies, which is usually not allowed due to safety and power-quality issues…”
    Get full text
    Journal Article
  14. 14

    Experimental Platform for Controlled Faults on Synchronous Generator Armature Windings by Monaro, R. M., Vieira, J. C. M., Coury, D. V., Malik, O. P.

    Published in IEEE transactions on energy conversion (01-12-2012)
    “…An experimental platform that allows application of internal faults on the armature windings of a specially modified synchronous generator in a controlled…”
    Get full text
    Journal Article
  15. 15

    Influence of excitation system control modes on the allowable penetration level of distributed synchronous generators by Freitas, W., Vieira, J.C.M., Morelato, A., Xu, W.

    Published in IEEE transactions on energy conversion (01-06-2005)
    “…This paper investigates the impacts of different excitation system control modes on potential factors that can limit the maximum allowable number of…”
    Get full text
    Journal Article
  16. 16

    Modeling and simulation of surge arresters for lightning protection of distribution systems by Ayres de Araujo, Marcel, Andrade Flauzino, Rogerio, de Cillo Moro, Vinicius, de Melo Vieira Jr, Jose Carlos

    Published in Revista IEEE América Latina (01-07-2015)
    “…Overvoltage protection systems are necessary to protect power system components against several types of overvoltages. In this paper, protection against…”
    Get full text
    Journal Article
  17. 17

    Voltage elevation analysis of overhead distribution lines using the finite element method by de Oliveira, P. S., Biasotto, E., Lima, M. A. A., Vieira, J. C. M., Oleskovicz, M., Coury, D. V., Suzuki, M., Miranda, S. A. N., Querne, H. F. R.

    “…This paper presents a methodological analysis to increase the power transfer capability of an overhead distribution line, by changing the rated voltage from…”
    Get full text
    Conference Proceeding
  18. 18

    Optimized power quality monitor placement based on a Particle Swarm Optimization algorithm by Bertho, R., Kempner, T. R., Vieira, J. C. M., Oleskovicz, M., Coury, D. V.

    “…The growing interest in the electricity industry regarding power quality has generated a high demand of network data to define the network status and points…”
    Get full text
    Conference Proceeding
  19. 19

    A methodology for training artificial neural networks for islanding detection of distributed generators by Merlin, V. L., Santos, R. C., Pavani, A. P. G., Coury, D. V., Oleskovicz, M., Vieira, J. C. M.

    “…The anti-islanding protection of synchronous generators is typically performed by voltage and frequency relays. However, one of the main issues related to…”
    Get full text