Construction and Performance of the Barrel Electromagnetic Calorimeter for the GlueX Experiment
NIM A896 (2018) 24-42 The barrel calorimeter is part of the new spectrometer installed in Hall D at Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013, commissioned in 2014 and has been operating routinely since early 2015. The detector configuration, associated Monte Carl...
Saved in:
Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Format: | Journal Article |
Language: | English |
Published: |
20-04-2018
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | NIM A896 (2018) 24-42 The barrel calorimeter is part of the new spectrometer installed in Hall D at
Jefferson Lab for the GlueX experiment. The calorimeter was installed in 2013,
commissioned in 2014 and has been operating routinely since early 2015. The
detector configuration, associated Monte Carlo simulations, calibration and
operational performance are described herein. The calorimeter records the time
and energy deposited by charged and neutral particles created by a multi-GeV
photon beam. It is constructed as a lead and scintillating-fiber calorimeter
and read out with 3840 large-area silicon photomultiplier arrays. Particles
impinge on the detector over a wide range of angles, from normal incidence at
90 degrees down to 11.5 degrees, which defines a geometry that is fairly unique
among calorimeters. The response of the calorimeter has been measured during a
running experiment and performs as expected for electromagnetic showers below
2.5 GeV. We characterize the performance of the BCAL using the energy
resolution integrated over typical angular distributions for $\pi^0$ and $\eta$
production of $\sigma_E/E$=5.2\%/$\sqrt{E(\rm{GeV})} \oplus$ 3.6\% and a timing
resolution of $\sigma$\,=\,150\,ps at 1\,GeV. |
---|---|
Bibliography: | JLAB-PHY-18-2624 |
DOI: | 10.48550/arxiv.1801.03088 |