Search Results - "Vasilescu, E."
-
1
Highly Sensitized Kidney Transplant Outcomes After the 2014 Kidney Allocation System Change
Published in Progress in transplantation (Aliso Viejo, Calif.) (01-09-2024)“…Introduction: Kidney Allocation System (KAS) was implemented by United Network for Organ Sharing in 2014 to reduce allocation disparities. Research Questions:…”
Get full text
Journal Article -
2
Profiling non‐HLA antibody responses in antibody‐mediated rejection following heart transplantation
Published in American journal of transplantation (01-09-2020)“…Antibody‐mediated rejection (AMR) driven by the development of donor‐specific antibodies (DSA) directed against mismatched donor human leukocyte antigen (HLA)…”
Get full text
Journal Article -
3
Long-term corrosion resistance of new Ti–Ta–Zr alloy in simulated physiological fluids by electrochemical and surface analysis methods
Published in Corrosion science (01-04-2015)“…[Display omitted] •Native passive film (TiO2, Ta2O5, ZrO2) on Ti–15Ta–5Zr alloy surface has a thickness of 8.5nm.•Duplex oxide film formed by inner, compact…”
Get full text
Journal Article -
4
Characterisation and corrosion resistance of the electrodeposited hydroxyapatite and bovine serum albumin/hydroxyapatite films on Ti–6Al–4V–1Zr alloy surface
Published in Corrosion science (01-03-2011)“…[Display omitted] ► EIS spectra for Ti6Al4V1Zr alloy were fitted with one time constant electric equivalent circuit. ► For covered alloy the equivalent circuit…”
Get full text
Journal Article -
5
Natural Antibodies Are Associated With Rejection and Long-term Renal Allograft Loss in a Multicenter International Cohort
Published in Transplantation (01-07-2023)“…Potentially harmful nonhuman leukocyte antigen antibodies have been identified in renal transplantation, including natural immunoglobulin G antibodies (Nabs)…”
Get full text
Journal Article -
6
Mechanical and corrosion resistance of a new nanostructured Ti–Zr–Ta–Nb alloy
Published in Journal of the mechanical behavior of biomedical materials (01-10-2011)“…In this work, a multi-elementary Ti–10Zr–5Nb–5Ta alloy, with non-toxic alloying elements, was used to develop an accumulative roll bonding, ARB-type procedure…”
Get full text
Journal Article -
7
Effect of thermo-mechanical processing on the corrosion resistance of Ti6Al4V alloys in biofluids
Published in Corrosion science (01-12-2009)“…Ti6Al4V-ELI alloy was plastically deformed at elevated temperatures in the range of β and α + β fields and was subsequently heat treated; so that five…”
Get full text
Journal Article -
8
Synthesis and characterisation of a new superelastic Ti–25Ta–25Nb biomedical alloy
Published in Journal of the mechanical behavior of biomedical materials (01-11-2010)“…In this study, a new Ti–25Ta–25Nb (mass%) beta alloy was synthesised by cold crucible semi-levitation melting. This technique made it possible to obtain…”
Get full text
Journal Article -
9
Alloantibodies in heart transplantation
Published in Human immunology (01-10-2009)“…Abstract The presence of complement fixing anti–human leukocyte antigen (HLA) antibodies in the circulation of organ transplant recipients may result in heart…”
Get full text
Journal Article -
10
Surface and electrochemical characterization of a new ternary titanium based alloy behaviour in electrolytes of varying pH
Published in Corrosion science (01-12-2013)“…[Display omitted] •Ti–15Zr–5Nb alloy exhibits a two-phase α+β lamellar microstructure.•Compact, native passive film (TiO2, Ti2O3, ZrO2, and Nb2O5) on alloy…”
Get full text
Journal Article -
11
New-onset graft dysfunction after heart transplantation—incidence and mechanism-related outcomes
Published in The Journal of heart and lung transplantation (01-02-2011)“…Background Graft dysfunction (GD) after heart transplantation (HTx) is a major cause of morbidity and mortality. The impact of different pathophysiologic…”
Get full text
Journal Article -
12
Microstructural, mechanical and anticorrosion characterisation of new CoCrNbMoZr alloy
Published in Materials and corrosion (01-07-2016)“…In this paper, the microstructure, mechanical and anticorrosive properties of the new CoCrNbMoZr alloy were studied in comparison with those of the commercial…”
Get full text
Journal Article -
13
In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy
Published in Journal of materials science. Materials in medicine (01-06-2010)“…One objective of this work was to study the corrosion resistance of the new implant Ti–10Zr–5Ta–5Nb alloy in physiological fluids of different pH values,…”
Get full text
Journal Article -
14
Characterisation of passive film and corrosion behaviour of a new Ti-Ta-Zr alloy in artificial oral media: In time influence of pH and fluoride ion content
Published in Materials and corrosion (01-09-2015)“…The new Ti‐15Ta‐5Zr alloy revealed a homogeneous bi‐phase α + β microstructure without inclusions or secondary phases. The alloy native passive film contains…”
Get full text
Journal Article -
15
P015
Published in Human immunology (01-10-2014)“…Aim The aim of this study was to evaluate the prognostic value of the C1q-SPA assay in recipients of kidney from deceased donors. Methods The study population…”
Get full text
Journal Article -
16
Long-term assessment of the implant titanium material—artificial saliva interface
Published in Journal of materials science. Materials in medicine (2008)“…This paper studies the long-term (20,000 exposure hours) behavior of titanium and Ti–5Al–4V alloy—Carter–Brugirard saliva interface and the short-term (500…”
Get full text
Journal Article -
17
Corrosion resistance of the new Ti-25Ta-25Nb alloy in severe functional conditions
Published in Materials and corrosion (01-11-2010)“…In this study, a new Ti‐25Ta‐25Nb (mass%) β alloy was synthesised by cold crucible semi‐levitation melting. After melting, each ingot was solution treated in…”
Get full text
Journal Article -
18
Long-term corrosion performances and cytocompatibility of nitrided Ti and Ti-6Al-4V alloy in severe functional conditions
Published in Materials and corrosion (01-06-2014)“…In the present work, nitrogen ion implantation (original method) to enhance the corrosion performance and cytocompatibility of biomedical pure titanium (CP Ti)…”
Get full text
Journal Article -
19
Improvement of the corrosion resistance and structural and mechanical properties of a titanium base alloy by thermo-mechanical processing
Published in Materials and corrosion (01-06-2013)“…In this work, a new ternary Ti–25Ta–5Zr alloy (with nontoxic alloying elements) was obtained and used to develop a thermo‐mechanical procedure in order to…”
Get full text
Journal Article -
20
Monitoring of titanium base alloys–biofluids interface
Published in Bioelectrochemistry (Amsterdam, Netherlands) (01-11-2007)“…Monitoring of the titanium, Ti–5Al–4V, Ti–6Al–4Fe implant materials — Ringer 1 and Ringer 2 solutions (of different pH values) interface for long term was…”
Get full text
Journal Article