Search Results - "Vanhees, Matthias"
-
1
Lateral Tibial Posterior Slope Is Increased in Patients With Early Graft Failure After Anterior Cruciate Ligament Reconstruction
Published in The American journal of sports medicine (01-10-2015)“…Background: The lateral tibial posterior slope (LTPS) has been reported in multiple studies to correlate with an increased risk for native anterior cruciate…”
Get full text
Journal Article -
2
Validation of a Simple Overlay Device to Assess Radial Head Implant Length
Published in The Journal of hand surgery (American ed.) (01-12-2018)“…A simple overlay device (SOD) was developed to measure radial head implant length. The purpose of this study was to determine the accuracy and reliability of…”
Get full text
Journal Article -
3
Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation
Published in Journal of shoulder and elbow surgery (2011)“…Hypothesis Navigation can improve accuracy of placement of the glenoid component in reversed shoulder arthroplasty. Material and methods A glenoid component of…”
Get full text
Journal Article -
4
Corrective osteotomy of distal radius malunions using three-dimensional computer simulation and patient-specific guides to achieve anatomic reduction
Published in European journal of orthopaedic surgery & traumatology (01-12-2018)“…Malunion is a common complication of distal radius fractures, especially those treated conservatively. In clinical studies, a significant correlation between…”
Get full text
Journal Article -
5
Transforming growth factor-β (TGF-β) expression is increased in the subsynovial connective tissue in a rabbit model of carpal tunnel syndrome
Published in PloS one (30-09-2014)“…Carpal tunnel syndrome (CTS) is an idiopathic disease that results from increased fibrosis of the subsynovial connective tissue (SSCT). A recent study found…”
Get full text
Journal Article -
6
Anthropometric Study of the Radio-Capitellar Joint
Published in Journal of shoulder and elbow surgery (01-08-2015)Get full text
Journal Article -
7
The Effect of Suture Preloading on the Force to Failure and Gap Formation After Flexor Tendon Repair
Published in The Journal of hand surgery (American ed.) (2013)“…Purpose Gap formation is a common and severe complication after flexor tendon repair that can affect the outcome and prolong tendon healing. The purpose of…”
Get full text
Journal Article -
8
Stemless revision of a failed hemiarthroplasty: case report and surgical technique
Published in Journal of shoulder and elbow surgery (01-09-2013)Get full text
Journal Article -
9
Reconstruction After Distal Biceps Tendon Rupture
Published in Journal of orthopaedics, trauma and rehabilitation (01-06-2012)“…Distal biceps ruptures are relatively uncommon, but should be diagnosed and treated promptly to have good outcome. In this review article we will briefly…”
Get full text
Journal Article -
10
Lateral Tibial Slope is Increased with Patients with Early Graft Failure Following ACL Reconstruction
Published in Orthopaedic journal of sports medicine (01-07-2014)“…Objectives: To determine the relationship between lateral tibial slope and probability of early graft failure in patients who have undergone anterior cruciate…”
Get full text
Journal Article -
11
The Effect of Time after Shear Injury on the Subsynovial Connective Tissue and Median Nerve within the Rabbit Carpal Tunnel
Published in Hand (New York, N.Y.) (01-03-2013)“…Background The most prominent nonneurological finding in the common compression neuropathy carpal tunnel syndrome (CTS) is fibrosis of the subsynovial…”
Get full text
Journal Article -
12
A proposal for name-tagging three-dimensional distal radial fracture fragments based on preliminary results
Published in The Journal of hand surgery, European volume (22-08-2024)“…Melone introduced a classification system for distal radial fractures, emphasizing the intra-articular patterns. We explore the significance of key part…”
Get full text
Journal Article -
13
Correction of scaphoid nonunion humpback deformity using three-dimensional printing technology
Published in The Journal of hand surgery, European volume (01-05-2021)Get full text
Journal Article -
14
Primary endoprosthetic replacement of the arthritic CMC-1 joint
Published in Operative Orthopädie und Traumatologie (01-06-2021)“…Objective Osteoarthritis of the carpometacarpal (CMC)-1 joint is a common condition that can cause significant pain and functional problems. When nonoperative…”
Get full text
Journal Article -
15
Real-Time Video Enhancement for the Removal of Surgical Lighting Artifacts in Computer-Assisted Orthopedic Surgery
Published in 2024 IEEE International Symposium on Biomedical Imaging (ISBI) (27-05-2024)“…Optical camera systems are commonly used to monitor patients in computer-assisted orthopedic surgery, but strong and flickering surgical lights interfere with…”
Get full text
Conference Proceeding -
16
The effect of knot position in Adelaide flexor tendon repairs
Published in The Journal of hand surgery, European volume (01-03-2020)Get full text
Journal Article -
17
Biomechanical considerations in the pathogenesis of osteoarthritis of the elbow
Published in Knee Surgery, Sports Traumatology, Arthroscopy (01-07-2016)“…Osteoarthritis is the most common joint disease and a major cause of disability. Distinct biological processes are considered crucial for the development of…”
Get full text
Journal Article Book Review -
18
A quantitative analysis of two cementing techniques in total elbow replacement: A cadaveric study
Published in Shoulder & elbow (01-10-2021)“…One of the reasons for failure of total elbow replacement is loosening of the ulnar component. Cementing techniques are often outdated. A special small nozzle…”
Get full text
Journal Article -
19
Computer Navigation and Patient-specific Instrumentation in Shoulder Arthroplasty
Published in Sports medicine and arthroscopy review (01-12-2014)“…Longevity of total anatomic and reversed shoulder arthroplasty largely depends on accurate correction of glenoid deformity and correct positioning and fixation…”
Get full text
Journal Article -
20
Anthropometric Study of the Radiocapitellar Joint
Published in The Journal of hand surgery (American ed.) (01-09-2018)“…There is scant knowledge about the relationship between the size of the radial head and the size of the capitellum. Also, no data exist comparing the size of…”
Get full text
Journal Article