Search Results - "Van der Wielen, C"

Refine Results
  1. 1

    Influence of Ring Main Units and Substations on Online Partial-Discharge Detection and Location in Medium-Voltage Cable Networks by Wagenaars, P, Wouters, P A A F, van der Wielen, P C J M, Steennis, E F

    Published in IEEE transactions on power delivery (01-04-2011)
    “…Online partial-discharge (PD) monitoring of medium-voltage power cables is traditionally performed on a cable between two consecutive ring main units (RMUs)…”
    Get full text
    Journal Article
  2. 2

    Approximation of transmission line parameters of single-core and three-core XLPE cables by Wagenaars, P., Wouters, P.A.A.F., Van Der Wielen, P.C.J.M., Steennis, E.F.

    “…A transmission line model of a power cable is required for the analysis of the behavior of high-frequency phenomena, such as partial discharges, lightning…”
    Get full text
    Journal Article
  3. 3
  4. 4

    Enforcement of the ban on aristolochic acids in Chinese traditional herbal preparations on the Dutch market by Martena, Martijn J, van der Wielen, Jacqueline C. A, van de Laak, Leo F. J, Konings, Erik J. M, de Groot, Henk N, Rietjens, Ivonne M. C. M

    Published in Analytical and bioanalytical chemistry (01-09-2007)
    “…In traditional chinese medicine several Aristolochia species are used. Aristolochia spp. contain a mixture of aristolochic acids (AAs), mainly AA I and AA II…”
    Get full text
    Journal Article
  5. 5

    Wave-Velocity Based Real-Time Thermal Monitoring of Medium-Voltage Underground Power Cables by de Clippelaar, Sven, Kruizinga, Bart, van der Wielen, Peter C. J. M., Wouters, Peter A. A. F.

    Published in IEEE transactions on power delivery (01-04-2024)
    “…Underground power cables are a bottleneck in congestion management for the medium-voltage grid because their ampacity is constrained by the maximum allowed…”
    Get full text
    Journal Article
  6. 6

    Rotational resonance NMR study of the active site structure in bacteriorhodopsin: conformation of the Schiff base linkage by Thompson, Lynmarie K, McDermott, Ann E, Raap, Jan, Van der Wielen, C. M, Lugtenburg, Johan, Herzfeld, Judith, Griffin, Robert G

    Published in Biochemistry (Easton) (01-09-1992)
    “…Rotational resonance, a new solid-state NMR technique for determining internuclear distances, is used to measure a distance in the active site of…”
    Get full text
    Journal Article
  7. 7

    Determination of the level of benzo[a]pyrene in fatty foods and food supplements by van der Wielen, J C A, Jansen, J T A, Martena, M J, De Groot, H N, In't Veld, P H

    Published in Food additives and contaminants (01-07-2006)
    “…A routine method was developed for the quantification of benzo[a]pyrene (BaP) in edible oils and food supplements. BaP is often taken as an indicator of the…”
    Get more information
    Journal Article
  8. 8

    Adaptive templates for matched filter bank for continuous online partial discharge monitoring by Wagenaars, P., Wouters, P. A. A. F., Van Der Wielen, P. C. J. M., Steennis, E. F.

    “…Matched filtering can be applied to recorded signals for maximum detection sensitivity during online partial discharge (PD) measurements in medium-voltage…”
    Get full text
    Journal Article
  9. 9
  10. 10
  11. 11

    Toxicological Evaluation of Waste-Water Samples to Appropriately Sensitized Cultured Fathead Minnow Cells Compared with the Microtox Assay by Scheers, E M, Van der Wielen, C, Dierickx, P J

    “…We have previously shown that a good correlation exists between in vitro cytotoxicity data to cultured fathead minnow (FHM) fish cells and fish lethality data…”
    Get full text
    Journal Article
  12. 12

    Risk-controlled application of current MV cable feeders in the future by intelligent continuous diagnostics by van der Wielen, P. C. J. M., Steennis, E. F.

    “…In future (smart) grids different load flows and patterns will occur. This will also have impact on the cable feeders between all smart appliances. Especially…”
    Get full text
    Conference Proceeding
  13. 13

    Practical experiences with on-line PD monitoring and interpretation for MV cable systems by Gargari, S M, Wouters, P A A F, van der Wielen, P C J M, Steennis, E F

    “…PD monitoring on-line with location (PD-OL) is one of the successful diagnostic tools for MV cable networks which has been recently introduced to the main…”
    Get full text
    Conference Proceeding
  14. 14

    Single-sided partial discharge location method based on impedance discontinuities along power cable by Yan Li, Wouters, Peter A. A. F., Wagenaars, Paul, van der Wielen, Peter C. J. M., Steennis, E. Fred

    Published in 2014 Power Systems Computation Conference (01-08-2014)
    “…Time domain reflectometry (TDR) applied to live cables is hampered by the absence of a clear reflection from the far end. Instead, location of partial…”
    Get full text
    Conference Proceeding
  15. 15

    Temperature dependent signal propagation velocity: possible indicator for mv cable dynamic rating by Yan Li, Wouters, Peter A. A. F., Wagenaars, Paul, van der Wielen, Peter C. J. M., Steennis, E. Fred

    “…Insulation temperature is the critical parameter for dynamic rating of underground power cables. Power cables on medium voltage (MV) level are too numerous and…”
    Get full text
    Journal Article
  16. 16

    Accurate estimation of the time-of-arrival of partial discharge pulses in cable systems in service by Wagenaars, P., Wouters, P.A.A.F., Van Der Wielen, P.C.J.M., Steennis, E.F.

    “…Accurate location of the origins of partial discharges in power cable systems, based on arrival times, is imperative for the identification and assessment of…”
    Get full text
    Journal Article
  17. 17

    Experiences with diagnostics on complete in-service MV cable feeders by van der Wielen, P. C. J. M., Steennis, E. F.

    “…By using an on-line continuous condition monitoring system, many problems in cable connections can be detected before leading to an outage. The system used for…”
    Get full text
    Conference Proceeding
  18. 18

    Partial discharge parameters to evaluate the insulation condition of on-line located defects in medium voltage cable networks by Gargari, S. Mousavi, Wouters, P. A. A. F., van der Wielen, P. C. J. M., Steennis, E. F.

    “…Partial discharge analysis has a long record as reliable diagnostic tool to assess the integrity and the quality of electrical insulation of power systems…”
    Get full text
    Journal Article
  19. 19

    Photoamperic probes in scanning tunneling microscopy by Prins, M. W. J., van der Wielen, M. C. M. M., Jansen, R., Abraham, D. L., van Kempen, H.

    Published in Applied physics letters (07-03-1994)
    “…The charge generated at the apex of a semiconductor tip upon laser irradiation is utilized in a scanning tunneling microscope. We show such arrangements can…”
    Get full text
    Journal Article
  20. 20

    Power cable joint modelin high frequency by Yan Li, Wouters, P. A. A. F., Wagenaars, P., van der Wielen, P. C. J. M., Steennis, E. F.

    “…Models in high frequency range for underground power cabling system are the basis for the analysis of many condition diagnostic techniques, for instance,…”
    Get full text
    Conference Proceeding