Search Results - "Van den Brom, H.E."

Refine Results
  1. 1

    Vibration Reed Electrometer for Accurate Measurement of Electrical Currents Below 10 pA by Rietveld, G., van den Brom, H.E.

    “…The paper is about developing a home-built vibrating reed (VR) electrometer. The heart of the meter is a VR capacitor, which excels in a stable and low input…”
    Get full text
    Journal Article
  2. 2

    Measurement Methods and Procedures for Assessing Accuracy of Instrument Transformers for Power Quality Measurements by Crotti, G., van den Brom, H.E., Mohns, E., Tinarelli, R., Luiso, M., Styblikova, R., Agazar, M, Cayci, H., Mazza, P., Meyer, J., Almutairi, M.

    “…Instrument transformers (ITs) are vital components of power quality (PQ) measurement systems in electrical transmission and distribution grids. Whereas…”
    Get full text
    Conference Proceeding
  3. 3

    Towards improved standardization of electricity meter testing by van den Brom, H.E., Rietveld, G., Hoogenboom, D., van Leeuwen, R., Marais, Z., Kok, G.J.P., Sharma, S., van Veghel, M.G.A.

    “…This paper describes present research towards improved standardization of static electricity meter testing with conducted electromagnetic interference (EMI)…”
    Get full text
    Conference Proceeding
  4. 4

    Operating Margins for a Pulse-Driven Josephson Arbitrary Waveform Synthesizer Using a Ternary Bit-Stream Generator by Houtzager, E., Benz, S.P., van den Brom, H.E.

    “…We describe measurements with a pulse-driven Josephson arbitrary waveform synthesizer (JAWS) that uses a ternary arbitrary bit-stream generator as the bias…”
    Get full text
    Journal Article
  5. 5

    DC and Low-Frequency Humidity Dependence of a 20 pF Air-Gap Capacitor by Rietveld, G., van den Brom, H.E.

    “…We have measured both the 0.01 Hz (quasi-dc) and 1.0 kHz values of a 20 pF room-temperature air-gap capacitor as a function of the environment. Its dependence…”
    Get full text
    Journal Article
  6. 6

    Accurate subpicoampere current source based on a differentiating capacitor with software-controlled nonlinearity compensation by van den Brom, H.E., de la Court, P., Rietveld, G.

    “…A high accuracy current source has been developed for the generation of very small currents (below 200 pA) based on applying a linear voltage ramp to a…”
    Get full text
    Journal Article
  7. 7

    Bipolar Pulse-Drive Electronics for a Josephson Arbitrary Waveform Synthesizer by van den Brom, H.E., Houtzager, E., Brinkmeier, B.E.R., Chevtchenko, O.A.

    “…A Josephson arbitrary waveform synthesizer (JAWS) has been developed in order to generate quantum-based ac voltage signals. The key component of this JAWS is a…”
    Get full text
    Journal Article
  8. 8

    Influence of Sampling Voltmeter Parameters on RMS Measurements of Josephson Stepwise-Approximated Sine Waves by van den Brom, H.E., Houtzager, E., Verhoeckx, S., Martina, Q.E.V.N., Rietveld, G.

    “…A binary Josephson-array voltage standard was used to investigate the influence of device settings on the reading of an 81/2-digit sampling voltmeter. This…”
    Get full text
    Journal Article
  9. 9

    Internally Damped CCC for Accurate Measurements of Small Electrical Currents by Rietveld, G., de la Court, P., van den Brom, H.E.

    “…We have developed and tested an internally damped cryogenic current comparator (CCC) with a main 1:20 000 winding ratio for the accurate measurement of small…”
    Get full text
    Journal Article
  10. 10

    Sensitivity of static energy meter reading errors to changes in non-sinusoidal load conditions by Marais, Z., van den Brom, H.E., Rietveld, G., van Leeuwen, R., Hoogenboom, D., Rens, J.

    “…Previous studies regarding static energy meter errors under non-sinusoidal load conditions have shown that these meters can produce erroneous readings. This…”
    Get full text
    Conference Proceeding
  11. 11

    Realization of a quantum standard for AC voltage: overview of a European research project by Chevtchenko, O.A., van den Brom, H.E., Houtzager, E., Behr, R., Kohlmann, J., Williams, J.M., Janssen, T.J.B.M., Palafox, L., Humphreys, D.A., Piquemal, F., Djordjevic, S., Monnoye, O., Poletaeff, A., Lapuh, R., Rydler, K.-E., Eklund, G.

    “…The European Josephson arbitrary waveform synthesizer (JAWS) project addresses the lack of instrumentation and knowledge for accurate and traceable measurement…”
    Get full text
    Journal Article
  12. 12

    Pulse-Driven Josephson Junction Arrays for High-Precision AC-Voltage Synthesis of Unipolar and Bipolar Waveforms by Schubert, M., Wende, G., May, T., Huebner, U., Meyer, H.-G., Chevtchenko, O.A., van den Brom, H.E., Houtzager, E.

    “…The paper is about development of the lumped Josephson junction arrays (JJAs) for the generation of accurate quantum-based ac voltages. By using semiconductor…”
    Get full text
    Journal Article
  13. 13

    Three-phase state estimation in the medium-voltage network with aggregated smart meter data by Ni, F., Nguyen, P.H., Cobben, J.F.G., Van den Brom, H.E., Zhao, D.

    “…•A new method to aggregate data from smart meters on the LV feeders is proposed.•Uncertainties associated with the aggregated smart meter data are…”
    Get full text
    Journal Article
  14. 14
  15. 15
  16. 16
  17. 17

    Evaluation of EMI Effects on Static Electricity Meters by Wright, P.S., Rietveld, G., Leferink, F., Van den Brom, H.E., Alonso, F.R.I, Braun, J.P., Ellingsberg, K., Pous, M., Svoboda, M.

    “…Recent studies involving large errors in static electricity meters when exposed to step changes in the current waveform are reviewed. Triggered by these…”
    Get full text
    Conference Proceeding
  18. 18

    DC and low frequency humidity dependence of an air-gap capacitor by Rietveld, G., van den Brom, H.E.

    “…We have measured both the 0.01 Hz (quasi-DC) and 1.0 kHz value of a room temperature air-gap capacitor as a function of environment (pressure, temperature,…”
    Get full text
    Conference Proceeding
  19. 19

    ACJVS operating margins using a ternary arbitrary bitstream generator by Houtzager, E., Benz, S.P., van den Brom, H.E.

    “…We describe measurements with a pulse-driven AC Josephson voltage standard (ACJVS) that uses a ternary arbitrary bitstream generator as the bias source. From…”
    Get full text
    Conference Proceeding
  20. 20

    Calibrating a sampling voltmeter using a binary Josephson system by van den Brom, H.E., Houtzager, E., Martina, Q.E.V.N., Rietveld, G.

    “…A binary Josephson system was used to characterize an 81/2-digit sampling voltmeter. This voltmeter is the heart of the primary standard for power at 50 Hz or…”
    Get full text
    Conference Proceeding