Search Results - "Valentinuzzi, M E"
-
1
Medium and interface components in impedance microbiology
Published in IEEE transactions on biomedical engineering (01-12-1999)“…Classic impedance microbiology (CIM) is based on the measurement of the impedance components that appear between a pair of electrodes submerged in a cell…”
Get full text
Journal Article -
2
Impedance microbiology: quantification of bacterial content in milk by means of capacitance growth curves
Published in Journal of microbiological methods (01-02-1999)“…The impedancimetric method is a technique for the rapid evaluation of milk bacterial content and also of its subproducts. Several authors have made use of…”
Get full text
Journal Article -
3
Arm EMG during abduction and adduction: hysteresis cycle
Published in Medical engineering & physics (01-05-2003)“…The electromyographic study of the muscles involved in the complex movements of the shoulder, is usually one way to quantifying the static and dynamic joint’s…”
Get full text
Journal Article -
4
Automatic on-line analyser of microbial growth using simultaneous measurements of impedance and turbidity
Published in Medical & biological engineering & computing (01-11-1999)“…An apparatus for the measurement of bacterial growth is described. The instrument applies alternate adequate sequential currents of two different frequencies…”
Get full text
Journal Article -
5
Parallel conductance determination in cardiac volumetry using dilution manoeuvres : theoretical analysis and practical implications
Published in Medical & biological engineering & computing (01-03-1999)“…Left ventricular volume calibration based on the conductance catheter depends on the correct determination of the parallel conductance (Gp). Baan's saline…”
Get full text
Journal Article -
6
The Dignity of Life and Death and the Power of Music
Published in Pacing and clinical electrophysiology (01-05-2001)Get full text
Journal Article -
7
Propagation velocity measurement : autocorrelation technique applied to the electromyogram
Published in Medical & biological engineering & computing (01-09-2001)“…Muscle fibre conduction velocity is an important measurement in electrophysiology, both in the research laboratory and in clinical practice. It is usually…”
Get full text
Journal Article -
8
The electrical conductance of a given volume is independent on the shape containing that volume
Published in Medical engineering & physics (01-11-1998)“…Studies have shown that when the length of an ideal cylinder is maintained constant and volume is modified by cross-sectional changes, the conductance becomes…”
Get full text
Journal Article -
9
Parallel conductance estimation by hypertonic dilution method with conductance catheter: effects of the bolus concentration and temperature
Published in IEEE transactions on biomedical engineering (01-07-1999)“…The conductance catheter has gained momentum since its introduction in cardiovascular dynamics back in 1980. However, measuring errors are still blurring its…”
Get full text
Journal Article -
10
Evidence for chaotic behavior in driven ventricles
Published in Biophysical journal (01-08-1989)“…Toad ventricles were externally driven by periodic pulses while monophasic action potential (MAP) signals were recorded in seven excised and seven in situ…”
Get full text
Journal Article -
11
Codman's paradox of the arm rotations is not a paradox: mathematical validation
Published in Medical engineering & physics (01-06-1998)“…Movement of a straight arm centred at the shoulder joint in three successive 90° rotations, each around the respective orthogonal coordinate axis, leads to an…”
Get full text
Journal Article -
12
Non-linear response of electrode–electrolyte interface at high current density
Published in Chaos, solitons and fractals (01-08-2005)“…A distributed parameter non-linear circuit is presented as fractal model of an electrode–electrolyte interface. It includes the charge transfer resistance and…”
Get full text
Journal Article -
13
Multichannel bacterial growth analyser by impedance and turbidity
Published in Medical & biological engineering & computing (01-11-1994)Get full text
Journal Article -
14
Hematocrit measurement by dielectric spectroscopy
Published in IEEE transactions on biomedical engineering (01-01-2005)“…Based on permittivity changes, a new method to measure hematocrit (HCT) in extracorporeal blood systems is presented. Human blood samples were tested at…”
Get full text
Journal Article -
15
Impedance bacteriometry: medium and interface contributions during bacterial growth
Published in IEEE transactions on biomedical engineering (01-12-1992)“…Impedance was measured in a cell containing culture broth inoculated with E. coli, before and during bacterial growth. The electrode interface impedance…”
Get full text
Journal Article -
16
Codman's Paradox: discussion leads to surprise and delight. Re: J.P. Paul, Medical Engineering & Physics 20 (1998):639
Published in Medical engineering & physics (01-03-1999)Get full text
Journal Article -
17
Conductivity and geometrical factors affecting volume measurements with an impedancimetric catheter
Published in Medical & biological engineering & computing (01-09-1986)Get full text
Journal Article -
18
Comparative analysis of hematocrit measurements by dielectric and impedance techniques
Published in IEEE transactions on biomedical engineering (01-03-2005)“…In a previous paper, a new dielectric technique was used to estimate hematocrit (HTC) in extracorporeal blood circulation systems, independently of plasma…”
Get full text
Journal Article -
19
Detection of left ventricular regional myocardial ischaemia in dogs by intraventricular conductance catheter
Published in Cardiovascular research (01-03-1988)“…Nine adult mongrel dogs were instrumented with ultrasonic microcrystals to measure left ventricular basal anteroposterior diameter and midwall myocardial…”
Get more information
Journal Article -
20
Efficiency of the heart as estimated from uncalibrated diagrams of intraventricular pressure related to conductance
Published in International journal of cardiology (01-01-1990)“…Using a diagram representing the relationship of intraventricular pressure and conductance, we determined ventricular efficiency from the weighted relationship…”
Get more information
Journal Article