Search Results - "Vaezy, Shahram"

Refine Results
  1. 1

    Hyperecho in ultrasound images of HIFU therapy: involvement of cavitation by Rabkin, Brian A, Zderic, Vesna, Vaezy, Shahram

    Published in Ultrasound in medicine & biology (01-07-2005)
    “…High-intensity focused ultrasound (US), or HIFU, treatment of soft tissues has been shown to result in a hyperechoic region in B-mode US images. We report on…”
    Get more information
    Journal Article
  2. 2

    Gel phantom for use in high-intensity focused ultrasound dosimetry by Lafon, Cyril, Zderic, Vesna, Noble, Misty L, Yuen, Jonathan C, Kaczkowski, Peter J, Sapozhnikov, Oleg A, Chavrier, Francoise, Crum, Lawrence A, Vaezy, Shahram

    Published in Ultrasound in medicine & biology (01-10-2005)
    “…An optically transparent phantom was developed for use in high-intensity focused ultrasound (US), or HIFU, dosimetry studies. The phantom is composed of…”
    Get more information
    Journal Article
  3. 3

    A Targeting Method Based on Acoustic Backscatter for Treatment Planning in Tissue Ablation Using Focused Ultrasound by Zheng, Xinliang, Vaezy, Shahram

    “…High-intensity focused ultrasound (HIFU) is a therapeutic modality that can produce coagulative necrosis in biological tissue, noninvasively. This technique…”
    Get full text
    Journal Article
  4. 4

    Prevention of post-focal thermal damage by formation of bubbles at the focus during high intensity focused ultrasound therapy by Zderic, Vesna, Foley, Jessica, Luo, Wenbo, Vaezy, Shahram

    Published in Medical physics (Lancaster) (01-10-2008)
    “…Safety concerns exist for potential thermal damage at tissue-air or tissue-bone interfaces located in the post-focal region during high intensity focused…”
    Get full text
    Journal Article
  5. 5

    Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging by Vaezy, S, Shi, X, Martin, R W, Chi, E, Nelson, P I, Bailey, M R, Crum, L A

    Published in Ultrasound in medicine & biology (01-01-2001)
    “…High-intensity focused ultrasound (HIFU) and conventional B-mode ultrasound (US) imaging were synchronized to develop a system for real-time visualization of…”
    Get more information
    Journal Article
  6. 6

    An image-guided high intensity focused ultrasound device for uterine fibroids treatment by Chan, Arthur H., Fujimoto, Victor Y., Moore, Donald E., Martin, Roy W., Vaezy, Shahram

    Published in Medical physics (Lancaster) (01-11-2002)
    “…A high intensity focused ultrasound (HIFU) device was developed for treating uterine fibroid tumors. This prototype device enables image-guided therapy by…”
    Get full text
    Journal Article
  7. 7

    IMAGE-GUIDED ACOUSTIC THERAPY by Vaezy, Shahram, Andrew, Marilee, Kaczkowski, Peter, Crum, Lawrence

    Published in Annual review of biomedical engineering (01-01-2001)
    “…The potential role of therapeutic ultrasound in medicine is promising. Currently, medical devices are being developed that utilize high-intensity focused…”
    Get full text
    Journal Article
  8. 8

    Detection and Localization of Peripheral Vascular Bleeding Using Doppler Ultrasound by Luo, Wenbo, PhD, Hosseini, Hamid, PhD, Zderic, Vesna, PhD, Mann, Frederick, MD, O'Keefe, Grant, MD, Vaezy, Shahram, PHD

    Published in The Journal of emergency medicine (01-07-2011)
    “…Abstract Background: Hemorrhage from wounds in the extremities is the leading cause of preventable death on the battlefield. To successfully treat these…”
    Get full text
    Journal Article
  9. 9

    Hemorrhage control in arteries using high-intensity focused ultrasound: A survival study by Zderic, Vesna, Keshavarzi, Amid, Noble, Misty L., Paun, Marla, Sharar, Sam R., Crum, Lawrence A., Martin, Roy W., Vaezy, Shahram

    Published in Ultrasonics (2006)
    “…High-intensity focused ultrasound (HIFU) has been shown to provide an effective method for hemorrhage control of blood vessels in acute animal studies. The…”
    Get full text
    Journal Article
  10. 10

    Treatment of uterine fibroid tumors in a nude mouse model using high-intensity focused ultrasound by Vaezy, Shahram, Fujimoto, Victor Y., Walker, Cheryl, Martin, Roy W., Chi, Emil Y., Crum, Lawrence A.

    “…Objective: The purpose of this study was to investigate the potential efficacy of high-intensity focused ultrasound for the treatment of uterine fibroid tumors…”
    Get full text
    Journal Article Conference Proceeding
  11. 11

    Use of high-intensity focused ultrasound to control bleeding by Vaezy, Shahram, Martin, Roy, Kaczkowski, Peter, Keilman, George, Goldman, Bryan, Yaziji, Hadi, Carter, Steve, Caps, Michael, Crum, Lawrence

    Published in Journal of vascular surgery (01-03-1999)
    “…Objective: High-intensity focused ultrasound (HIFU) has been shown to be effective in controlling hemorrhage from punctures in blood vessels. The objective of…”
    Get full text
    Journal Article
  12. 12

    Note to Physicians and Sonographers on Potential Underestimation of Acoustic Safety Indexes for Diagnostic Array Transducers by Wear, Keith A., Vaezy, Shahram

    “…Two scientists from the U.S. Food and Drug Administration comment on limitations of acoustic safety indexes that can arise from spatial averaging effects of…”
    Get full text
    Journal Article
  13. 13

    Hemostasis of punctured blood vessels using high-intensity focused ultrasound by Vaezy, S, Martin, R, Yaziji, H, Kaczkowski, P, Keilman, G, Carter, S, Caps, M, Chi, E Y, Bailey, M, Crum, L

    Published in Ultrasound in medicine & biology (01-07-1998)
    “…The hemorrhagic complications of vascular injury can be significant. We report on the use of high-intensity focused ultrasound (HIFU) to stop the hemorrhage of…”
    Get more information
    Journal Article
  14. 14

    Quantitative investigation of acoustic streaming in blood by Shi, Xuegong, Martin, Roy W, Vaezy, Shahram, Crum, Lawrence A

    “…Acoustic streaming may have practical utility in diagnostic medical ultrasound in distinguishing between stagnant blood and tissue as well as clotted and…”
    Get full text
    Journal Article
  15. 15

    Tissue ablation using high-intensity focused ultrasound in the fetal sheep model: potential for fetal treatment by Paek, Bettina W, Vaezy, Shahram, Fujimoto, Vic, Bailey, Michael, Albanese, Craig T, Harrison, Michael R, Farmer, Diana L

    “…The aim of this study was to investigate the efficacy of high-intensity focused ultrasound (HIFU) ablation of fetal tissue in a sheep model. HIFU can deliver…”
    Get full text
    Journal Article Conference Proceeding
  16. 16

    Hemorrhage control using high intensity focused ultrasound by Vaezy, Shahram, Zderic, Vesna

    “…Hemorrhage control is a high priority task in advanced trauma care, because hemorrhagic shock can result in less than a minute in cases of severe injuries…”
    Get more information
    Journal Article
  17. 17
  18. 18

    Color Doppler detection of acoustic streaming in a hematoma model by Shi, X, Martin, R W, Vaezy, S, Kaczkowski, P, Crum, L A

    Published in Ultrasound in medicine & biology (01-09-2001)
    “…Accurate differentiation between stagnant blood and soft tissue or clotted and unclotted blood has potential value in managing trauma patients with internal…”
    Get more information
    Journal Article
  19. 19
  20. 20