Search Results - "Ugorowski, P."

  • Showing 1 - 20 results of 20
Refine Results
  1. 1
  2. 2
  3. 3

    Search for low-energy induced depletion of 178Hfm2 at the SPring-8 synchrotron by Carroll, J.J., Karamian, S.A., Propri, R., Gohlke, D., Caldwell, N., Ugorowski, P., Drummond, T., Lazich, J., Roberts, H., Helba, M., Zhong, Z., Tang, M.-T., Lee, J.-J., Liang, K.

    Published in Physics letters. B (01-08-2009)
    “…Electromagnetic transitions within nuclei reflect specific aspects of nuclear structure. This is particularly true for metastable excited states, or isomers,…”
    Get full text
    Journal Article
  4. 4
  5. 5

    Design and performance of a Compton-coincidence system for measuring non-proportionality of new scintillators by Ugorowski, P.B., Harrison, M.J., McGregor, D.S.

    “…A Compton-coincidence scintillator light yield non-proportionality measurement system was constructed and tested. Improved testing procedures and timing…”
    Get full text
    Journal Article
  6. 6

    Compact, inexpensive, high-energy-resolution, room-temperature-operated, semiconductor gamma-ray detectors for isotope identification by Ugorowski, P, Ariesanti, A, McGregor, D S, Kargar, A

    “…Many homeland security applications involving gamma-ray detectors require energy resolution of better than 1%-2% for isotope identification. Existing…”
    Get full text
    Conference Proceeding
  7. 7

    An accurate and portable solid state neutron rem meter by Oakes, T.M., Bellinger, S.L., Miller, W.H., Myers, E.R., Fronk, R.G., Cooper, B.W, Sobering, T.J., Scott, P.R., Ugorowski, P., McGregor, D.S, Shultis, J.K., Caruso, A.N.

    “…Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15MeV energy range with a single configuration and lightweight instrument is…”
    Get full text
    Journal Article
  8. 8
  9. 9
  10. 10
  11. 11
  12. 12

    Growth and preparation of LiZnP and LiZnAs for solid-state neutron detectors by Montag, B. W., Nelson, K. A., Reichenberger, M. A., Arpin, K. R., McDonald, H. E., Browning, S. R., Ugorowski, P. B., McGregor, D. S.

    “…Most gas-filled neutron detectors are difficult to manufacture as compact detectors. Boron-based compounds, such as BP, BN and BAs have shown limited success,…”
    Get full text
    Conference Proceeding
  13. 13

    Preliminary results of KSU Frisch-collar CZT array by Ugorowski, P. B., Brooks, A. C., Taylor, R. D., Sobering, T. J., Mcgregor, D. S.

    “…Cadmium zinc telluride (CdZnTe or CZT) is a well-known problematic material once dimensions exceed ~1cm ∧ 3, due to material imperfections that cause severe…”
    Get full text
    Conference Proceeding
  14. 14

    A Compton-scattering coincidence system for light yield measurements on aliovalently-doped CeBr3 by Ugorowski, P., J. Harrison, M., Linnick, C., Brinton, S., McGregor, D. S.

    “…A Compton-coincidence scintillator light yield proportionality measurement system was constructed and tested. Improved testing procedures and timing resolution…”
    Get full text
    Conference Proceeding
  15. 15

    Inverted Pockels cell electro-optic response to nuclear reactor pulsing by Nelson, K. A., Arpin, K. R., Geuther, J. A., Neihart, J. L., Riedel, T. A., Rojeski, R. A., Ugorowski, P. B., McGregor, D. S.

    “…A new method to detect neutron radiation based on an electro-optic Pockels cell is reported. Collimated laser light passes through a radiation-sensitive…”
    Get full text
    Conference Proceeding
  16. 16
  17. 17

    1-D array of micro-structured neutron detectors by McNeil, W.J., Bellinger, S.L., Unruh, T.C., Henderson, C.M., Ugorowski, P.B., Dunn, W.L., Taylor, R.D., Blalock, B.J., Britton, C.L., McGregor, D.S.

    “…A 1024-channel pixel array has been constructed utilizing the perforated diode neutron detector design currently produced at Kansas State University. In this…”
    Get full text
    Conference Proceeding
  18. 18

    Characterization of the High-Efficiency Neutron Detector Array (HENDA) by Ugorowski, P., Bellinger, S., Crow, L., Henderson, C., Dunn, W.L., McNeil, W.J., Taylor, R.D., McGregor, D. S.

    “…Two new pixellated neutron detectors developed at the Semiconductor Materials and Radiological Technologies Laboratory (SMART Lab) at Kansas State University,…”
    Get full text
    Conference Proceeding
  19. 19
  20. 20