Search Results - "Udod, V. A."

Refine Results
  1. 1

    Mathematical Modeling of Radiation Transparencies in the Computational Implementation of the Dual Energy Method Based on the Analog Amplitude Analysis of Initial Signals by Udod, V. A., Vorobeichikov, S. E., Osipov, S. P.

    “…A mathematical model of radiation transparencies in the computational implementation of the dual energy method based on analog discrimination of the initial…”
    Get full text
    Journal Article
  2. 2

    Algorithm for Optimizing the Parameters of Sandwich X-ray Detectors by Udod, V. A., Osipov, S. P., Nazarenko, S. Yu

    Published in Russian journal of nondestructive testing (01-03-2023)
    “…We describe an algorithm for optimizing the parameters of sandwich X-ray detectors in relation to the recognition of materials by the dual energy method. The…”
    Get full text
    Journal Article
  3. 3

    Identification of materials in X-Ray inspections of objects by the dual-energy method by Osipov, S. P., Udod, V. A., Wang, Y.

    Published in Russian journal of nondestructive testing (01-08-2017)
    “…The state-of-the-art, application experience, and trends in further perfection of the dualenergy method as used in digital-radiography and X-ray…”
    Get full text
    Journal Article
  4. 4

    Algorithm for Evaluating Errors in Recognition of Materials in X-Ray Testing System Containing X-Ray Sandwich Detectors by Udod, V. A., Osipov, S. P., Nazarenko, S. Yu

    “…We describe our proposed algorithm for statistical estimation of the error of the dual energy method due to the quantum nature of radiation as applied to an…”
    Get full text
    Journal Article
  5. 5

    Mathematical Models of Radiation Transparency of Test Objects When Using Sandwich X-Ray Radiation Detectors by Udod, V. A., Vorobeichikov, S. E., Nazarenko, S. Yu

    Published in Russian journal of nondestructive testing (01-02-2020)
    “…A mathematical model of the output signals of an X-ray sandwich detector is presented. Based on this model, two mathematical models of the radiation…”
    Get full text
    Journal Article
  6. 6

    Estimating the Influence of Quantum Noises on the Quality of Material Identification by the Dual-Energy Method by Udod, V. A., Osipov, S. P., Wang, Y.

    Published in Russian journal of nondestructive testing (01-08-2018)
    “…A mathematical model has been developed to describe the radiation transparency of a test object with allowance for quantum noise. The technique of estimating…”
    Get full text
    Journal Article
  7. 7

    Comparative Analysis of Various Definitions of the Concept of Effective Atomic Number of Material of a Multicomponent Object by Udod, V. A., Osipov, S. P., Wang, Y.

    Published in Russian journal of nondestructive testing (01-09-2018)
    “…Comparative analysis is provided for various definitions of the concept of effective atomic number as applied to the material of a multicomponent object…”
    Get full text
    Journal Article
  8. 8

    A Cumulative Sums Algorithm for Segmentation of Digital X-ray Images by Vorobeychikov, S. E., Chakhlov, S. V., Udod, V. A.

    Published in Journal of nondestructive evaluation (01-09-2019)
    “…A mathematical model of digital X-ray image of the test object is presented for the case when the main type of image distortion is the noise due to the quantum…”
    Get full text
    Journal Article
  9. 9

    State-of-the art and development prospects of digital radiography systems for nondestructive testing, evaluation, and inspection of objects: a review by Udod, V. A., Van, Ya, Osipov, S. P., Chakhlov, S. V., Usachev, E. Yu, Lebedev, M. B., Temnik, A. K.

    Published in Russian journal of nondestructive testing (01-09-2016)
    “…A review of modern state and practical applications of various digital radiography systems that are intended for nondestructive testing, evaluation, and…”
    Get full text
    Journal Article
  10. 10

    Estimating the efficiency of two algorithms for segmentation of digital radiation images of test objects by Vorobeichikov, S. E., Fokin, V. A., Udod, V. A., Temnik, A. K.

    Published in Russian journal of nondestructive testing (01-02-2017)
    “…A mathematical model that describes digital radiation images of test objects is presented. Two algorithms are given for automatic segmentation of digital…”
    Get full text
    Journal Article
  11. 11

    A study of two image-recognition algorithms for the classification of flaws in a test object according to its digital image by Vorobeichikov, S. E., Fokin, V. A., Udod, V. A., Temnik, A. K.

    Published in Russian journal of nondestructive testing (01-10-2015)
    “…The mathematical model of a digital radiation image is given that corresponds to a test object that contains two types of defects, namely, pores and cracks (or…”
    Get full text
    Journal Article
  12. 12

    The Upper Resolution Threshold of Digital Radiographic Scanning Systems by Udod, V A

    Published in Russian journal of nondestructive testing (01-03-2004)
    “…The upper resolution threshold in the scanning direction has been determined for scanning digital radiographic systems containing a line of detectors with a…”
    Get full text
    Journal Article
  13. 13

    Generalization of relation between shadow X-ray image and frequency of pulses at the output of a scanning detector by NEDAVNII, O. N, UDOD, V. A

    Published in Russian journal of nondestructive testing (01-06-2000)
    “…A relation of a fairly general character has been established between a shadow X-ray image and frequency of random electric pulses generated by a detector of a…”
    Get full text
    Journal Article
  14. 14

    Optimal selection of parameters of multichannel continuously scanning digital-radiography systems by Lebedev, M. B., Sidulenko, O. A., Udod, V. A.

    Published in Russian journal of nondestructive testing (01-10-2009)
    “…For continuously scanning digital-radiography systems containing a linear detector array, a problem of optimal selection of the length and width of the…”
    Get full text
    Journal Article
  15. 15

    Optimization the parameters of multichannel continuously scanning digital X-ray radiography systems by Udod, V. A., Lebedev, M. B., Klimenov, V. A., Solodushkin, V. I., Temnik, A. K.

    Published in Russian journal of nondestructive testing (01-02-2011)
    “…Analytical formulas for optimal selection of the values of the main parameters of a multichannel continuously scanning digital X-ray radiography system, which…”
    Get full text
    Journal Article
  16. 16

    A model of quantum noise in shadow radiation images by Nedavnii, O. I., Udod, V. A.

    Published in Russian journal of nondestructive testing (01-06-2000)
    “…Correlation characteristics of a quantum noise in shadow X-ray images have been determined. A simple expression describing the structure of this noise has been…”
    Get full text
    Journal Article
  17. 17

    A mathematical model of multichannel continuously scanning systems for digital X-ray analysis by Lebedev, M. B., Sidulenko, O. A., Udod, V. A.

    Published in Russian journal of nondestructive testing (01-06-2007)
    “…A mathematical model of continuously scanning systems for digital X-ray analysis is developed. The systems contain a linear array of detectors that can be used…”
    Get full text
    Journal Article
  18. 18

    Selecting parameters of discrete scanning systems for digital X-ray imaging by Lebedev, M B, Sidulenko, O A, Udod, V A

    Published in Russian journal of nondestructive testing (01-11-2006)
    “…For discrete scanning systems of digital X-ray imaging that contain an array of detectors, optimum values of the aperture length for each detector in the array…”
    Get full text
    Journal Article
  19. 19

    The current state and prospects of X-ray computational tomography by Chakhlov, S. V., Osipov, S. P., Temnik, A. K., Udod, V. A.

    Published in Russian journal of nondestructive testing (01-04-2016)
    “…A short review of the current state of X-ray computational tomography and its practical applications in nondestructive testing and diagnostics is given…”
    Get full text
    Journal Article
  20. 20

    An algorithm for the automatic detection of inclusions in an inspected object with a scanning digital X-ray imaging system (one-dimensional variant) by Vorobeichikov, S. E., Udod, V. A., Klimenov, V. A., Shchetinkin, S. A.

    Published in Russian journal of nondestructive testing (01-06-2014)
    “…The mathematical model of an output digital signal from a single measuring channel of a scanning digital X-ray imaging system containing a line of detectors is…”
    Get full text
    Journal Article