Search Results - "Turneaure, J.P."
-
1
A space-based superconducting microwave oscillator clock
Published in Advances in space research (2000)“…Superconducting Cavity Stabilized Oscillators, SCSO, have produced the most stable clocks to date, achieving an Allen variance of 3×10 −16 for integration…”
Get full text
Journal Article -
2
The Gravity Probe B Relativity Mission
Published in Advances in space research (2000)“…The NASA/Stanford Relativity Mission Gravity Probe B (GP-B) experiment will provide two extremely precise tests of General Relativity based on observations of…”
Get full text
Journal Article -
3
Development of the Gravity Probe B flight mission
Published in Advances in space research (01-10-2003)“…Gravity Probe B is an experiment to measure the geodetic and frame-dragging precessions, relative to the “fixed” “stars”, of a gyroscope placed in a 650 km…”
Get full text
Journal Article -
4
Cryogenic gyroscopes for the relativity mission
Published in Physica. B, Condensed matter (01-05-2000)“…The relativity mission, also known as gravity probe B (GP-B), uses high-precision electrostatically suspended cryogenic gyroscopes for measuring the…”
Get full text
Journal Article -
5
Gravity Probe B payload verification and test program
Published in Advances in space research (01-10-2003)“…Most of the Flight Payload hardware for the Gravity Probe B Relativity Mission is currently being manufactured. The design, fabrication, and integration of…”
Get full text
Journal Article -
6
Gyroscopes and charge control for the Relativity Mission Gravity Probe B
Published in Advances in space research (2000)“…The most demanding goal of the Gravity Probe B Relativity Mission (GP-B) is the measurement of the parametrized post-Newtonian parameter γ to one part in 10 5…”
Get full text
Journal Article -
7
Multilayer films of TiC, Ti and Cu for the gravity probe B relativity mission gyroscopes
Published in Surface & coatings technology (01-12-1995)“…Single-component and multilayer films of TiC, Ti and Cu have been produced by sputtering on fused quartz substrates and have been investigated for suitability…”
Get full text
Journal Article -
8
Observation of the London moment and trapped flux in precision gyroscopes
Published in IEEE transactions on applied superconductivity (01-03-1993)“…The London-moment readout has been observed in flight quality gyroscopes and it has been demonstrated that it is possible to reduce magnetic field trapped in…”
Get full text
Journal Article Conference Proceeding -
9
A Superconducting Cavity Stabilized Oscillator
Published in 26th Annual Symposium on Frequency Control (1972)Get full text
Conference Proceeding -
10
Gravity Probe B – Testing Einstein at the Limits of Engineering
Published in Nuclear physics. Section B, Proceedings supplement (01-04-2007)“…The Gravity Probe B experiment was developed to test two predictions of General Relativity; the Geodetic and the frame-dragging precessions of a mechanical…”
Get full text
Journal Article -
11
Superconducting-cavity stabilized oscillators with improved frequency stability
Published in Proceedings of the IEEE (01-01-1975)“…X-band microwave oscillators stabilized with superconducting niobium cavities with loaded Q's of about 10 10 achieved short-term frequency stabilities as low…”
Get full text
Journal Article -
12
Elimination on electron multipacting in superconducting structures for electron accelerators
Published in Applied physics letters (15-10-1977)“…Electron multipacting in a 2.8-GHz TM010-mode anodized niobium test cavity at 1.4 K has been studied experimentally. An electron multipactor simulation…”
Get full text
Journal Article -
13
Measurements on Superconducting Nb Prototype Structures at 1300 MHz
Published in IEEE transactions on nuclear science (01-01-1971)“…Twenty-four low temperature measurements have been made on six different superconducting Nb cavities at 1300 NHz. These cavities were fabricated using Nb sheet…”
Get full text
Journal Article -
14
A superconducting microwave oscillator clock for use on the Space Station
Published in Proceedings of the 1998 IEEE International Frequency Control Symposium (Cat. No.98CH36165) (1998)“…The International Space Station provides an ideal platform for high precision frequency measurements, both as applied to scientific experiments and as regards…”
Get full text
Conference Proceeding -
15
The Development of Superconducting Cavity Stabilized Oscillator
Published in 27th Annual Symposium on Frequency Control (1973)Get full text
Conference Proceeding -
16
Performance of 6-m 1300-MHz superconducting niobium accelerator structures
Published in Applied physics letters (15-08-1974)“…The design, manufacture, and performance of several 6-m-long 1300-MHz superconducting niobium accelerator structures, which are part of the Stanford…”
Get full text
Journal Article -
17
Demonstration of the superconducting electron accelerator as a high-intensity high-resolution device
Published in Applied physics letters (01-06-1973)“…In recent experiments with the superconducting injector system, beam intensity and beam quality objectives for the superconducting electron accelerator have…”
Get full text
Journal Article -
18
Low Temperature Aspects of a Cryogenic Accelerator
Published in IEEE transactions on nuclear science (1967)“…The object of this paper is to identify the many low temperature aspects of a cryogenic accelerator and to indicate how these are related to the operating…”
Get full text
Journal Article -
19
Test of the principle of equivalence by a null gravitational red-shift experiment
Published in Physical review. D, Particles and fields (15-04-1983)“…A test of the Einstein equivalence principle (EEP) was performed by carrying out a 'null' gravitational red-shift experiment. The experiment compared the rates…”
Get full text
Journal Article