Air insulated LTD stage with stored energy of 5.5 kJ and output power of 14 GW

In the report we present the design and test results of the linear transformer driver (LTD) stage that does not need any liquid or compressed gas for insulation inside the cavity and operation of the switches. The only gas, which is used, is air at atmospheric pressure. At peak charge voltage of 85...

Full description

Saved in:
Bibliographic Details
Published in:Digest of Technical Papers. PPC-2003. 14th IEEE International Pulsed Power Conference (IEEE Cat. No.03CH37472) Vol. 2; pp. 1455 - 1457 Vol.2
Main Authors: Kovalchuk, B.M., Kim, A.A., Kumpjak, E.V., Tsou, N.V.
Format: Conference Proceeding
Language:English
Published: IEEE 2003
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In the report we present the design and test results of the linear transformer driver (LTD) stage that does not need any liquid or compressed gas for insulation inside the cavity and operation of the switches. The only gas, which is used, is air at atmospheric pressure. At peak charge voltage of 85 kV the stage delivers to the matched load of /spl sim/0.15 Ohms the 14 GW power pulse with the rise time of /spl sim/180 ns. The stage is developed to demonstrate the possibility to simplify the LTD technology of the primary energy storages in maintenance and application.
ISBN:0780379152
9780780379152
DOI:10.1109/PPC.2003.1278090