Search Results - "Tsapaki, V"

Refine Results
  1. 1

    Radiation protection in dental radiology – Recent advances and future directions by Tsapaki, V.

    Published in Physica medica (01-12-2017)
    “…•Diagnostic reference levels must be defined in cone beam Computed Tomography (CBCT).•Use of lead apron for gonadal and foetal protection is not…”
    Get full text
    Journal Article
  2. 2

    Evaluation of image quality and patient exposure in fluoroscopy using a phantom: Is there any clinical relevance? by Tsalafoutas, I.A., Tsapaki, V., Triantopoulou, I.

    Published in European journal of radiology (01-05-2021)
    “…•Modern X-ray systems have numerous X-ray preset protocols; some are a “black box”.•X-ray system manufacturers offer more radiation optimization tools than in…”
    Get full text
    Journal Article
  3. 3
  4. 4

    Dose management software implementation in mammography by Samara, E.T., Tsapaki, V., Sramek, D.

    Published in Physica medica (01-12-2019)
    “…•Dose management software (DMS) facilitated analysis of clinical and technical parameters.•DMS facilitated evaluation of radiographers’ performance.•DMS…”
    Get full text
    Journal Article
  5. 5

    The International Atomic Energy Agency action plan on radiation protection of patients and staff in interventional procedures: Achieving change in practice by Tsapaki, V., Balter, S., Cousins, C., Holmberg, O., Miller, D.L., Miranda, P., Rehani, M., Vano, E.

    Published in Physica medica (01-08-2018)
    “…•Manufacturers play an important role in making patients safer.•Automatic patient dose (skin dose maps) reporting are essential for optimization.•More studies…”
    Get full text
    Journal Article
  6. 6

    CONE BEAM CT IN DENTAL IMPLANT PLANNING: HOW CLOSE ARE PATIENT DOSIMETRY RESULTS WITH DATA FROM PHANTOM STUDIES FOUND IN LITERATURE? by Kottou, S, Zapros, A, Stefanopoulou, N, Krompas, N, Tsapaki, V

    Published in Radiation protection dosimetry (31-12-2019)
    “…Advantages of Cone Beam Computed Tomography (CBCT) include high-quality 3D imaging and reduced radiation exposure with relatively low cost. In this study,…”
    Get full text
    Journal Article
  7. 7

    Radiation protection in digestive endoscopy: European Society of Digestive Endoscopy (ESGE) guideline by Dumonceau, J-M, Garcia-Fernandez, F J, Verdun, F R, Carinou, E, Donadille, L, Damilakis, J, Mouzas, I, Paraskeva, K, Ruiz-Lopez, N, Struelens, L, Tsapaki, V, Vanhavere, F, Valatas, V, Sans-Merce, M

    Published in Endoscopy (01-04-2012)
    “…This article expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about radiation protection for endoscopic procedures, in…”
    Get more information
    Journal Article
  8. 8

    Towards the definition of Institutional diagnostic reference levels in paediatric interventional cardiology procedures in Greece by Kottou, S., Kollaros, N., Plemmenos, C., Mastorakou, I., Apostolopoulou, S.C., Tsapaki, V.

    Published in Physica medica (01-02-2018)
    “…•The aim was to evaluate paediatric radiation doses in a dedicated cardiac hospital.•The large range of patient dose data observed mainly depends on procedure…”
    Get full text
    Journal Article
  9. 9

    Does clinical indication play a role in CT radiation dose in pediatric patients? by Tsapaki, V, Triantopoulou, S

    Published in Physica medica (01-09-2016)
    “…Introduction There are many types of medical imaging procedures that are applied on children. Imaging has to take into account the dynamics of a growing body,…”
    Get full text
    Journal Article
  10. 10

    Leadership and mentoring in medical physics: The experience of a medical physics international mentoring program by Santos, J.C., Goulart, L.F., Giansante, L., Lin, Y.H., Sirico, A.C.A., Ng, A.H., Tsapaki, V., Bezak, E., Ng, K.H.

    Published in Physica medica (01-08-2020)
    “…•Online mentoring is useful to support young professionals in developing countries.•The impact of a global mentoring program on career development of young…”
    Get full text
    Journal Article
  11. 11

    Management of difficult bile duct stones and indeterminate bile duct structures: Reduced ERCP radiation exposure with adjunct use of digital single-operator cholangioscopy by Tsapaki, V., Papastergiou, V., Giannakopoulos, A., Angelogiannopoulou, P., Delatolas, V., Triantopoulou, S., Theocharis, S., Paraskeva, K.

    Published in Physica medica (01-08-2019)
    “…•Digital cholangioscopy (DA) with ERCP is associated with much shorter fluoro time.•DA with ERCP is associated with substantially lower radiation dose.•DA with…”
    Get full text
    Journal Article
  12. 12

    THE IMPACT OF X-RAY UNIT TYPE USED FOR ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURES ON PATIENT DOSES by Tsapaki, V, Paraskeva, K D, Tsalafoutas, I A, Paspatis, G, Scotiniotis, H, Georgopoulos, P, Finou, P, Karagianis, J A

    Published in Radiation protection dosimetry (01-12-2016)
    “…To investigate whether the X-ray unit type used for interventional endoscopic retrograde cholangiopancreatography (ERCP) procedures may affect patient…”
    Get full text
    Journal Article
  13. 13

    Dual-energy contrast-enhanced digital mammography: patient radiation dose estimation using a Monte Carlo code by Yakoumakis, E, Tzamicha, E, Dimitriadis, A, Georgiou, E, Tsapaki, V, Chalazonitis, A

    Published in Radiation protection dosimetry (01-07-2015)
    “…Mammography is a standard procedure that facilitates breast cancer detection. Initial results of contrast-enhanced digital mammography (CEDM) are promising…”
    Get full text
    Journal Article
  14. 14

    Measuring skin dose in CT examinations under complex geometries: Instruments, methods and considerations by Tsalafoutas, I.A, Epistatou, A, Nikoletopoulos, S, Tsapaki, V

    Published in Physica medica (01-12-2015)
    “…Highlights • Skin dose can be high in CT procedures where multiple scans are performed. • Skin dose within gantry is gradually reduced when moving away from…”
    Get full text
    Journal Article
  15. 15

    Patient radiation doses in various fluoroscopically guided orthopaedic procedures by Tsapaki, V, Tsalafoutas, I A, Fagkrezos, D, Lazaretos, I, Nikolaou, V S, Efstathopoulos, N

    Published in Radiation protection dosimetry (01-01-2016)
    “…All orthopaedic fluoroscopic procedures performed using C-arm guidance were monitored for 1 y. The type of procedure, fluoroscopy time (T), kerma-area product…”
    Get full text
    Journal Article
  16. 16

    Paediatric multi detector computed tomography radiation doses in a dedicated paediatric hospital in Greece by Akrividou, D, Douskas, G, Stratigopoulou, A, Evlogias, N, Tsapaki, V

    Published in Physica medica (01-09-2016)
    “…Introduction Multi detector CT (MDCT) X-ray systems provide high quality paediatric imaging. However, the last years, concern has been expressed on radiation…”
    Get full text
    Journal Article
  17. 17

    Cone beam CT radiation dose in dental implant surgery by Stefanopoulou, N, Fotos, N, Tsapaki, V, Kouratiadis, G, Krompas, N

    Published in Physica medica (01-09-2016)
    “…Introduction New applications of CT are still shown, the most prominent example of which is the development of Cone Beam Computed Tomography (CBCT) for dental…”
    Get full text
    Journal Article
  18. 18

    Preliminary reference levels in interventional cardiology by Neofotistou, V, Vano, E, Padovani, R, Kotre, J, Dowling, A, Toivonen, M, Kottou, S, Tsapaki, V, Willis, S, Bernardi, G, Faulkner, K

    Published in European radiology (01-10-2003)
    “…This article describes the European DIMOND approach to defining reference levels (RLs) for radiation doses delivered to patients during two types of invasive…”
    Get full text
    Journal Article
  19. 19

    Reference levels at European level for cardiac interventional procedures by Padovani, R., Vano, E., Trianni, A., Bokou, C., Bosmans, H., Bor, D., Jankowski, J., Torbica, P., Kepler, K., Dowling, A., Milu, C., Tsapaki, V., Salat, D., Vassileva, J., Faulkner, K.

    Published in Radiation protection dosimetry (2008)
    “…In interventional cardiology, a wide variation in patient dose for the same type of procedure has been recognised by different studies. Variation is almost due…”
    Get full text
    Journal Article
  20. 20

    EUTEMPE-RX, an EC supported FP7 project for the training and education of medical physics experts in radiology by Bosmans, H, Bliznakova, K, Padovani, R, Christofides, S, Van Peteghem, N, Tsapaki, V, Caruana, C J, Vassileva, J

    Published in Radiation protection dosimetry (01-07-2015)
    “…The core activity of the medical physics expert (MPE) is to ensure optimal use of ionising radiation in healthcare. It is essential that these healthcare…”
    Get full text
    Journal Article