Search Results - "Tsalafoutas, I."
-
1
Evaluation of image quality and patient exposure in fluoroscopy using a phantom: Is there any clinical relevance?
Published in European journal of radiology (01-05-2021)“…•Modern X-ray systems have numerous X-ray preset protocols; some are a “black box”.•X-ray system manufacturers offer more radiation optimization tools than in…”
Get full text
Journal Article -
2
PATIENT DOSES IN WHOLE-BODY PET/CT EXAMINATIONS IN THE LARGEST TERTIARY HOSPITAL IN GREECE
Published in Radiation protection dosimetry (17-12-2021)“…Abstract The purpose of this study was to determine the patient radiation dose in combined whole-body positron emission tomography/computed tomography (PET/CT)…”
Get full text
Journal Article -
3
A method for calculating the dose length product from CT DICOM images
Published in British journal of radiology (01-03-2011)“…The dosimetric calculations in CT examinations are currently based on two quantities: the volume weighted CT dose index (CTDI(vol)) and the dose-length product…”
Get full text
Journal Article -
4
The potential role of brachytherapy in the irradiation of patients with lung cancer: a systematic review
Published in Clinical & translational oncology (01-08-2017)“…To review the use of brachytherapy as an adjuvant therapy to reduce recurrences after sublobar resections and as a palliation to patients with inoperable…”
Get full text
Journal Article -
5
The impact of image processing algorithms on digital radiography of patients with metalic hip implants
Published in Physica medica (01-08-2019)“…•Image processing of digital radiographs aims to enhance the visibility of the anatomic areas of interest.•Image processing algorithms may adversely affect…”
Get full text
Journal Article -
6
THE IMPACT OF X-RAY UNIT TYPE USED FOR ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY PROCEDURES ON PATIENT DOSES
Published in Radiation protection dosimetry (01-12-2016)“…To investigate whether the X-ray unit type used for interventional endoscopic retrograde cholangiopancreatography (ERCP) procedures may affect patient…”
Get full text
Journal Article -
7
Linac beam data measurement using a detector array
Published in Physica medica (01-09-2016)“…Introduction As new treatment advances are implemented in a radiotherapy department, the QA workload increases requiring more resources. Unplanned maintenance…”
Get full text
Journal Article -
8
Large sample neutron activation analysis of irregular-shaped pottery artifacts
Published in Journal of radioanalytical and nuclear chemistry (01-01-2015)“…The large sample neutron activation analysis (LSNAA) method developed at NCSR “Demokritos” for large and irregular-shaped objects was applied for the analysis…”
Get full text
Journal Article -
9
Patient radiation doses in various fluoroscopically guided orthopaedic procedures
Published in Radiation protection dosimetry (01-01-2016)“…All orthopaedic fluoroscopic procedures performed using C-arm guidance were monitored for 1 y. The type of procedure, fluoroscopy time (T), kerma-area product…”
Get full text
Journal Article -
10
Dual-energy contrast-enhanced digital mammography: Glandular dose estimation using a Monte Carlo code and voxel phantom
Published in Physica medica (01-11-2015)“…Abstract Purpose To estimate the mean glandular dose of contrast enhanced digital mammography, using the EGSnrc Monte Carlo code and female adult voxel…”
Get full text
Journal Article -
11
Measuring skin dose in CT examinations under complex geometries: Instruments, methods and considerations
Published in Physica medica (01-12-2015)“…Highlights • Skin dose can be high in CT procedures where multiple scans are performed. • Skin dose within gantry is gradually reduced when moving away from…”
Get full text
Journal Article -
12
PO-386 ENDOBRONCHIAL BRACHYTHERAPYAS ADJUVANT TREATMENTIN PRIMARY BRONCHIAL N.S.C.L.C TUMORS
Published in Radiotherapy and oncology (01-05-2012)Get full text
Journal Article -
13
Excessive leakage radiation measured on two mobile X-ray units due to the methodology used by the manufacturer to calculate and specify the required tube shielding
Published in British journal of radiology (01-02-2006)“…During the quality control (QC) procedure of a new mobile X-ray unit, it was revealed that the leakage radiation was well in excess of the current limit of 1…”
Get full text
Journal Article -
14
Radiation doses to patients undergoing standard radiographic examinations: a comparison between two methods
Published in British journal of radiology (01-02-2007)“…The objective of the study was to derive a mathematical method for calculating the entrance surface dose (ESD) from exposure factors for all tube potentials…”
Get full text
Journal Article -
15
Radiation dose in repeated CT guided radiofrequency ablations
Published in Physica medica (01-02-2014)“…Abstract Objective To calculate the cumulative effective and skin doses in patients that underwent repeated CT guided radiofrequency ablations (RFA). Materials…”
Get full text
Journal Article -
16
Exposure range limits of three intraoral image receptors for various tube potential, tube current and exposure time settings
Published in Physica medica (2014)Get full text
Journal Article -
17
A COMPREHENSIVE METHOD FOR CALCULATING SHIELDING REQUIREMENTS FOR THE IMAGING ROOM OF PET/CT INSTALLATIONS
Published in Physica medica (01-12-2022)Get full text
Journal Article -
18
O.4.6 - A COMPREHENSIVE METHOD FOR CALCULATING SHIELDING REQUIREMENTS FOR THE IMAGING ROOM OF PET/CT INSTALLATIONS
Published in Physica medica (01-12-2022)Get full text
Journal Article -
19
Analysis of radiological examination request forms in conjunction with justification of X-ray exposures
Published in European journal of radiology (01-02-2005)“…Objectives: To evaluate the adequacy of patient data and clinical information transmitted to the radiological departments by the referring clinicians in view…”
Get full text
Journal Article -
20
Effective and ovarian dose in PA conventional and rotational 3D hysterosalpingography examinations
Published in Physica medica (01-09-2013)“…Abstract The purpose of this study was to compare effective and ovarian doses (E and OD, respectively) in hysterosalpingography (HSG) examinations performed…”
Get full text
Journal Article