Search Results - "Trotier, Aurelien J."

Refine Results
  1. 1

    The Compressed Sensing MP2RAGE as a Surrogate to the MPRAGE for Neuroimaging at 3 T by Trotier, Aurélien J., Dilharreguy, Bixente, Anandra, Serge, Corbin, Nadège, Lefrançois, William, Ozenne, Valery, Miraux, Sylvain, Ribot, Emeline J.

    Published in Investigative radiology (01-06-2022)
    “…The magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) sequence provides quantitative T1 maps in addition to high-contrast morphological…”
    Get full text
    Journal Article
  2. 2

    2D multislice MP2RAGE sequence for fast T1 mapping at 7 T: Application to mouse imaging and MR thermometry by Faller, Thibaut L., Trotier, Aurélien J., Rousseau, Alice F., Franconi, Jean‐Michel, Miraux, Sylvain, Ribot, Emeline J.

    Published in Magnetic resonance in medicine (01-09-2020)
    “…Purpose To develop a 2D radial multislice MP2RAGE sequence for fast and reliable T1 mapping at 7 T in mice and for MR thermometry. Methods The 2D‐MP2RAGE…”
    Get full text
    Journal Article
  3. 3

    Fast 3D ultrashort echo‐time spiral projection imaging using golden‐angle: A flexible protocol for in vivo mouse imaging at high magnetic field by Castets, Charles R., Lefrançois, William, Wecker, Didier, Ribot, Emeline J., Trotier, Aurélien J., Thiaudière, Eric, Franconi, Jean‐Michel, Miraux, Sylvain

    Published in Magnetic resonance in medicine (01-05-2017)
    “…Purpose To develop a fast three‐dimensional (3D) k‐space encoding method based on spiral projection imaging (SPI) with an interleaved golden‐angle approach and…”
    Get full text
    Journal Article
  4. 4
  5. 5
  6. 6

    USPIO-enhanced 3D-cine self-gated cardiac MRI based on a stack-of-stars golden angle short echo time sequence: Application on mice with acute myocardial infarction by Trotier, Aurélien J., Castets, Charles R., Lefrançois, William, Ribot, Emeline J., Franconi, Jean-Michel, Thiaudière, Eric, Miraux, Sylvain

    Published in Journal of magnetic resonance imaging (01-08-2016)
    “…Purpose To develop and assess a 3D‐cine self‐gated method for cardiac imaging of murine models. Materials and Methods A 3D stack‐of‐stars (SOS) short echo time…”
    Get full text
    Journal Article
  7. 7

    Positive contrast high-resolution 3D-cine imaging of the cardiovascular system in small animals using a UTE sequence and iron nanoparticles at 4.7, 7 and 9.4 T by Trotier, Aurélien J, Lefrançois, William, Van Renterghem, Kris, Franconi, Jean-Michel, Thiaudière, Eric, Miraux, Sylvain

    “…To show that 3D sequences with ultra-short echo times (UTEs) can generate a positive contrast whatever the magnetic field (4.7, 7 or 9.4 T) and whatever Ultra…”
    Get full text
    Journal Article
  8. 8

    Free-breathing 3D diffusion MRI for high-resolution hepatic metastasis characterization in small animals by Ribot, Emeline J., Trotier, Aurélien J., Castets, Charles R., Dallaudière, Benjamin, Thiaudière, Eric, Franconi, Jean-Michel, Miraux, Sylvain

    Published in Clinical & experimental metastasis (01-02-2016)
    “…The goal of this study was to develop a 3D diffusion weighted sequence for free breathing liver imaging in small animals at high magnetic field. Hepatic…”
    Get full text
    Journal Article
  9. 9

    Whole-brain T 2 mapping with radial sampling and retrospective motion correction at 3T by Corbin, Nadège, Trotier, Aurelien J, Anandra, Serge, Kadalie, Emile, Dallet, Laurence, Miraux, Sylvain, Ribot, Emeline J

    Published in Magnetic resonance in medicine (04-10-2024)
    “…Several barriers prevent the use of whole-brain T mapping in routine use despite increasing interest in this parameter. One of the main barriers is the long…”
    Get full text
    Journal Article
  10. 10

    Whole-brain T2 mapping with radial sampling and retrospective motion correction at 3T by Corbin, Nadège, Trotier, Aurelien J, Anandra, Serge, Kadalie, Emile, Dallet, Laurence, Miraux, Sylvain, Ribot, Emeline J

    Published in Magnetic resonance in medicine (04-10-2024)
    “…Several barriers prevent the use of whole-brain T2 mapping in routine use despite increasing interest in this parameter. One of the main barriers is the long…”
    Get full text
    Journal Article
  11. 11

    Accelerated 3D multi‐echo spin‐echo sequence with a subspace constrained reconstruction for whole mouse brain T2 mapping by Trotier, Aurélien J., Corbin, Nadège, Miraux, Sylvain, Ribot, Emeline J.

    Published in Magnetic resonance in medicine (01-10-2024)
    “…Purpose To accelerate whole‐brain quantitative T2$$ {\mathrm{T}}_2 $$ mapping in preclinical imaging setting. Methods A three‐dimensional (3D) multi‐echo spin…”
    Get full text
    Journal Article
  12. 12

    Rapid whole brain 3D T2 mapping respiratory‐resolved Double‐Echo Steady State (DESS) sequence with improved repeatability by Kadalie, Emile, Trotier, Aurélien J., Corbin, Nadège, Miraux, Sylvain, Ribot, Emeline J.

    Published in Magnetic resonance in medicine (01-01-2024)
    “…Purpose To propose a quantitative 3D double‐echo steady‐state (DESS) sequence that offers rapid and repeatable T2 mapping of the human brain using different…”
    Get full text
    Journal Article
  13. 13

    Compressed‐Sensing MP2RAGE sequence: Application to the detection of brain metastases in mice at 7T by Trotier, Aurélien J., Rapacchi, Stanislas, Faller, Thibaut L., Miraux, Sylvain, Ribot, Emeline J.

    Published in Magnetic resonance in medicine (01-01-2019)
    “…Purpose To develop a Compressed Sensing (CS)‐MP2RAGE sequence to drastically shorten acquisition duration and then detect and measure the T1 of brain…”
    Get full text
    Journal Article
  14. 14
  15. 15

    Deep learning model for automatic segmentation of lungs and pulmonary metastasis in small animal MR images by Lefevre, Edgar, Bouilhol, Emmanuel, Chauvière, Antoine, Souleyreau, Wilfried, Derieppe, Marie-Alix, Trotier, Aurélien J., Miraux, Sylvain, Bikfalvi, Andreas, Ribot, Emeline J., Nikolski, Macha

    Published in Frontiers in bioinformatics (12-10-2022)
    “…Lungs are the most frequent site of metastases growth. The amount and size of pulmonary metastases acquired from MRI imaging data are the important criteria to…”
    Get full text
    Journal Article
  16. 16

    Water Selective Imaging and bSSFP Banding Artifact Correction in Humans and Small Animals at 3T and 7T, Respectively by Ribot, Emeline J, Wecker, Didier, Trotier, Aurélien J, Dallaudière, Benjamin, Lefrançois, William, Thiaudière, Eric, Franconi, Jean-Michel, Miraux, Sylvain

    Published in PloS one (01-10-2015)
    “…The purpose of this paper is to develop an easy method to generate both fat signal and banding artifact free 3D balanced Steady State Free Precession (bSSFP)…”
    Get full text
    Journal Article
  17. 17

    Time-resolved TOF MR angiography in mice using a prospective 3D radial double golden angle approach by Trotier, Aurelien J., Lefrançois, William, Ribot, Emeline J., Thiaudiere, Eric, Franconi, Jean-Michel, Miraux, Sylvain

    Published in Magnetic resonance in medicine (01-03-2015)
    “…Purpose To develop an undersampled anatomical, three‐dimensional (3‐D) time‐resolved magnetic resonance angiography (MRA) method for small animals based on…”
    Get full text
    Journal Article
  18. 18

    Self‐gated bSSFP sequences to detect iron‐labeled cancer cells and/or metastases in vivo in mouse liver at 7 Tesla by Ribot, Emeline J., Duriez, Tom J., Trotier, Aurélien J., Thiaudiere, Eric, Franconi, Jean‐Michel, Miraux, Sylvain

    Published in Journal of magnetic resonance imaging (01-05-2015)
    “…Background To develop and evaluate three‐dimensional (3D) self‐gated balanced steady state free precession (bSSFP) imaging at high magnetic fields to track…”
    Get full text
    Journal Article
  19. 19

    Radial MP2RAGE sequence for rapid 3D T 1 mapping of mouse abdomen: application to hepatic metastases by Faller, Thibaut L, Trotier, Aurélien J, Miraux, Sylvain, Ribot, Emeline J

    Published in European radiology (01-11-2019)
    “…The T longitudinal recovery time is regarded as a biomarker of cancer treatment efficiency. In this scope, the Magnetization Prepared 2 RApid Gradient Echo…”
    Get full text
    Journal Article
  20. 20

    2D multislice MP2RAGE sequence for fast T 1 mapping at 7 T: Application to mouse imaging and MR thermometry by Faller, Thibaut L, Trotier, Aurélien J, Rousseau, Alice F, Franconi, Jean-Michel, Miraux, Sylvain, Ribot, Emeline J

    Published in Magnetic resonance in medicine (01-09-2020)
    “…To develop a 2D radial multislice MP2RAGE sequence for fast and reliable T mapping at 7 T in mice and for MR thermometry. The 2D-MP2RAGE sequence was performed…”
    Get full text
    Journal Article