Search Results - "Treves Brown, Bernard J"
-
1
A microfluidic device for self-synchronised production of droplets
Published in Lab on a chip (07-12-2011)“…The primary requirement for a mixing operation in droplet-based microfluidic devices is an accurate pairing of droplets of reaction fluids over an extended…”
Get more information
Journal Article -
2
miniaturised isotachophoresis method for magnesium determination
Published in Analytical and bioanalytical chemistry (01-07-2009)“…The use of malonic acid as a complexing agent has enabled a new method to be devised to allow the determination of magnesium to be made using miniaturised…”
Get full text
Journal Article -
3
Scaling-up ultrasound standing wave enhanced sedimentation filters
Published in Ultrasonics (01-02-2015)“…•Scale-up of resonant chambers is limited by heat from out of phase interface contacts.•Experimental data is given for a system with pin contacts and a single…”
Get full text
Journal Article -
4
Miniaturised free flow isotachophoresis of bacteria using an injection moulded separation device
Published in Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (15-08-2012)“…► A new design of injection moulded free flow electrophoresis separation device has been produced. ► The new design of device has been successfully used for…”
Get full text
Journal Article -
5
Bacteria detection using disposable optical leaky waveguide sensors
Published in Biosensors & bioelectronics (15-08-2005)“…Novel disposable absorbing material clad leaky waveguide sensor devices (LWD) have been developed for the detection of pathogenic particles such as bacteria…”
Get full text
Journal Article -
6
Optimisation and analysis of microreactor designs for microfluidic gradient generation using a purpose built optical detection system for entire chip imaging
Published in Lab on a chip (01-01-2009)“…This paper presents and fully characterises a novel simplification approach for the development of microsystem based concentration gradient generators with…”
Get more information
Journal Article -
7
Hybrid Microfluidic Sensors Fabricated by Screen Printing and Injection Molding for Electrochemical and Electrochemiluminescence Detection
Published in Electroanalysis (New York, N.Y.) (01-02-2009)“…An integrated microfluidic/electrochemical sensor with a dual working electrode configuration was fabricated for voltammetric and electrochemiluminescence…”
Get full text
Journal Article -
8
Systematic linearisation of a microfluidic gradient network with unequal solution inlet viscosities demonstrated using glycerol
Published in Microfluidics and nanofluidics (01-05-2010)“…This paper presents a mathematical and experimental study of the effect of inlet concentration (and therefore viscosity) of glycerol solutions on the…”
Get full text
Journal Article -
9
An integrated optical leaky waveguide sensor with electrically induced concentration system for the detection of bacteria
Published in Lab on a chip (01-01-2005)“…An integrated, sensitive and rapid system was developed for the detection of bacteria. The system combined an optical metal-clad leaky waveguide (MCLW) sensor…”
Get more information
Journal Article -
10
Novel microsystems for concentration gradient generation through computer optimization with validation using optical instrumentation
Published in Microelectronic engineering (01-05-2008)“…Novel microfluidic resistive network designs have been evaluated theoretically and experimentally. Such networks are an important component of microreactor…”
Get full text
Journal Article Conference Proceeding -
11
Free flow isotachophoresis in an injection moulded miniaturised separation chamber with integrated electrodes
Published in Journal of Chromatography A (06-07-2007)“…An injection moulded free flow isotachophoresis (FFITP) microdevice with integrated carbon fibre loaded electrodes with a separation chamber of 36.4 mm wide,…”
Get full text
Journal Article Conference Proceeding -
12
Optical imaging and analytical modelling of the dynamic concentration gradient of viscous inlet solutions in a microfabricated network design
Published in Microelectronic engineering (01-04-2009)“…The design and operation of a gradient network is particularly critical when mixing solutions of different viscosities, which is common with real samples,…”
Get full text
Journal Article Conference Proceeding -
13
Miniaturised isotachophoresis of DNA
Published in Journal of Chromatography A (13-07-2007)“…This paper presents the findings of a feasibility study investigating the behaviour of DNA under conditions of miniaturised isotachophoresis. An electrolyte…”
Get full text
Journal Article Conference Proceeding -
14
Toward a Microfluidic-Based Rapid Amylase Assay System
Published in Journal of food science (01-08-2009)“…This article describes work into a prototype system for the assay of amylase, using microfludic technologies. The new system has a significantly shorter cycle…”
Get full text
Journal Article -
15
An Integrated Metal Clad Leaky Waveguide Sensor for Detection of Bacteria
Published in Analytical chemistry (Washington) (01-01-2005)“…An integrated optical metal clad leaky waveguide (MCLW) sensor device has been developed for the detection of bacteria. This is more sensitive than waveguide…”
Get full text
Journal Article -
16
Determination of the potassium content of explosive residues using miniaturised isotachophoresis
Published in Electrophoresis (01-11-2010)“…A new method has been developed to allow the determination of potassium in post‐explosion residues to be made using miniaturised isotachophoresis. The method…”
Get full text
Journal Article -
17
Determination of chlorine containing species in explosive residues using chip-based isotachophoresis
Published in Journal of Chromatography A (27-06-2008)“…A new method has been developed to allow the determination of the chlorate, chloride and perchlorate anions in inorganic explosive residues to be made using…”
Get full text
Journal Article -
18
Optical Leaky Waveguide Sensor for Detection of Bacteria with Ultrasound Attractor Force
Published in Analytical chemistry (Washington) (01-10-2005)“…An integrated, sensitive, and rapid system was developed for the detection of bacteria. The system combined an optical metal-clad leaky waveguide (MCLW) sensor…”
Get full text
Journal Article -
19
Miniaturised isotachophoretic analysis of inorganic arsenic speciation using a planar polymer chip with integrated conductivity detection
Published in Journal of Chromatography A (21-03-2003)“…A new method allowing the analysis of inorganic arsenic species using isotachophoresis has been developed. This method has been shown to be suitable for use on…”
Get full text
Journal Article -
20
Rapid chloride analysis using miniaturised isotachophoresis
Published in Journal of Chromatography A (30-06-2006)“…A new design of miniaturised separation device for performing isotachophoresis (ITP) has been produced. The device contains a simple arrangement of channels…”
Get full text
Journal Article Conference Proceeding