Search Results - "Tralshawala, N."

Refine Results
  1. 1

    Practical SQUID Instrument for Nondestructive Testing by Tralshawala, N., Claycomb, J. R., Miller, John H., Jr

    Published in Applied physics letters (15-09-1997)
    “…We report on the development of a scanning eddy-current imaging system designed to detect deep subsurface flaws in conducting materials. A high transition…”
    Get full text
    Journal Article
  2. 2

    Design and fabrication of superconducting transition edge X-ray calorimeters by Tralshawala, N, Aslam, S, Brekosky, R.P, Chen, T.C, Figueroa Feliciano, E, Finkbeiner, F.M, Li, M.J, Mott, D.B, Stahle, C.K, Stahle, C.M

    “…We report on progress made so far at NASA Goddard Space Flight Center towards the development of arrays of X-ray microcalorimeters as candidates for the…”
    Get full text
    Journal Article
  3. 3

    Tunnelling evidence for predominantly electron-phonon coupling in superconducting Ba1-xKxBiO3 and Nd2-xCexCuO4-y by HUANG, Q, ZASADZINSKI, J. F, TRALSHAWALA, N, GRAY, K. E, HINKS, D. G, PENG, J. L, GREENE, R. L

    Published in Nature (London) (27-09-1990)
    “…At low temperatures, uj crn is just the strong-coupling analogue, N(E), of the BCS density of states, NBCS(E). [...]ProQuest: ... denotes formula omitted.)…”
    Get full text
    Journal Article
  4. 4

    Theoretical investigation of eddy-current induction for nondestructive evaluation by superconducting quantum interference devices by Claycomb, J.R., Tralshawala, N., Miller, J.H.

    Published in IEEE transactions on magnetics (01-01-2000)
    “…An analysis of eddy-current induction is presented for applications in low-frequency electromagnetic nondestructive evaluation (NDE) using superconducting…”
    Get full text
    Journal Article
  5. 5

    Nondestructive evaluation of wires using high-temperature SQUIDs by Weinstock, H., Tralshawala, N., Claycomb, J.R.

    “…A method using SQUID magnetometry and low-frequency current injection has been developed to detect defects during the fabrication of single and multi-strand…”
    Get full text
    Journal Article Conference Proceeding
  6. 6
  7. 7

    Fabrication of Mo/Au transition-edge sensors for X-ray spectrometry by Tralshawala, N., Brekosky, R.P., Li, M.J., Figueroa-Feliciano, E., Finkbeiner, F.M., Lindeman, M.A., Stahle, C.M., Stahle, C.K.

    “…We present fabrication details of our Mo/Au X-ray microcalorimeters, which are being developed as one of the candidate high resolution spectrometers for the…”
    Get full text
    Journal Article Conference Proceeding
  8. 8

    Characterization of the interface between a normal metal and a superconductor using magnetic screening by Soulen, R.J., Claassen, J.H., Osofsky, M.S., Trotter, G., Woods, G.T., Ovchinnikov, Yu.N., Kresen, V., Tralshawala, N.

    “…We have predicted the behavior of magnetic screening of N/I/S trilayers as a function of a single parameter W that parameterizes the discontinuity of the order…”
    Get full text
    Journal Article
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13

    Reduction of ambient magnetic field noise for high-T/sub c/ SQUID applications by Tralshawala, N., Claycomb, J.R., Miller, J.H.

    “…We discuss results of our investigations on ambient noise reduction using localized high-T/sub c/ (HTS) passive magnetic shields. We have quantified our…”
    Get full text
    Journal Article
  14. 14

    Imaging defects in Cu-clad NbTi wire using a high-T sub(c) scanning SQUID microscope by Fleet, E, Gilbertson, A, Chatraphorn, S, Tralshawala, N, Weinstock, H, Wellstood, F C

    “…We have used a sensitive magnetic microscope based on the dc Superconducting Quantum Interference Device (SQUID) to examine room-temperature samples of…”
    Get full text
    Journal Article
  15. 15

    Imaging defects in Cu-clad NbTi wire using a high-T/sub c/ scanning SQUID microscope by Fleet, E., Gilbertson, A., Chatraphorn, S., Tralshawala, N., Weinstock, H., Wellstood, F.C.

    “…We have used a sensitive magnetic microscope based on the dc Superconducting Quantum Interference Device (SQUID) to examine room-temperature samples of Cu-clad…”
    Get full text
    Journal Article
  16. 16

    Imaging defects in Cu-clad NbTi wire using a high-T)c)scanning SQUID microscope by Fleet, E, Gilbertson, A, Chatraphorn, S, Tralshawala, N, Weinstock, H, Wellstood, F C

    “…We have used a sensitive magnetic microscope based on the dc Superconducting Quantum Interference Device (SQUID) to examine room-temperature samples of Cu-clad…”
    Get full text
    Journal Article
  17. 17

    High-T/sub c/ superconducting image surface magnetometers by Tralshawala, N., Miller, J.H., Jackson, D.R.

    “…We present an overview of the concepts of image surface magnetometry, and analyze various shapes of superconducting shields in the presence of uniform…”
    Get full text
    Journal Article
  18. 18

    Reduction of ambient magnetic field noise for high-T(c) SQUID applications by Tralshawala, N, Claycomb, J R, Miller, J H

    “…We discuss results of our investigations on ambient noise reduction using localized high-T(c) (HTS) passive magnetic shields. We have quantified our results in…”
    Get full text
    Journal Article
  19. 19

    Processing and characterization of high T/sub c/ magnetic shields and flux transformers by Ponnusamy, D., Tralshawala, N., Claycomb, J.R., Miller, J.H., Ravi-Chandar, K., Salama, K.

    “…The use of high T/sub c/ SQUID (HTSQUID) magnetometers for magnetocardiography (MCG) and nondestructive testing (NDT) requires effective shielding from…”
    Get full text
    Journal Article
  20. 20

    Processing and characterization of high T(c) magnetic shields and flux transformers by Ponnusamy, D, Tralshawala, N, Claycomb, J R, Miller, J H, Ravi-Chandar, K, Salama, K

    “…The use of high T(c) SQUID (HTSQUID) magnetometers for magnetocardiography (MCG) and nondestructive testing (NDT) requires effective shielding from magnetic…”
    Get full text
    Journal Article