Search Results - "Tomov, B.T"
-
1
Inner magnetosphere variations after Solar Proton Events. Observations on Mir space station in 1989–1994 time period
Published in Advances in space research (01-01-1998)“…Measurements on board the Mir space station have been used to study the dose rate and the particle flux distribution in the inner magnetosphere. The…”
Get full text
Journal Article -
2
Relativistic electron fluxes and dose rate variations observed on the international space station
Published in Journal of atmospheric and solar-terrestrial physics (01-07-2013)“…The paper presents observations of relativistic electron precipitations (REP) on the International Space Station (ISS) obtained by three Bulgarian-built…”
Get full text
Journal Article -
3
“BION-M” No. 1 spacecraft radiation environment as observed by the RD3-B3 radiometer-dosimeter in April–May 2013
Published in Journal of atmospheric and solar-terrestrial physics (01-02-2015)“…Space radiation has been monitored using the РД3-Б3 (in the following we use the Latin transcription RD3-B3) spectrometer–dosimeter on board a recent space…”
Get full text
Journal Article -
4
Overview of the Liulin type instruments for space radiation measurement and their scientific results
Published in Life sciences in space research (01-01-2015)“…Ionizing radiation is recognized to be one of the main health concerns for humans in the space radiation environment. Estimation of space radiation effects on…”
Get full text
Journal Article -
5
High dose rates obtained outside ISS in June 2015 during SEP event
Published in Life sciences in space research (01-06-2016)“…•The Bulgarian build R3DR2 instrument on the European Space Agency (ESA) EXPOSE-R2 platform outside the Russian “Zvezda” module of the International Space…”
Get full text
Journal Article -
6
An overview of RADOM results for earth and moon radiation environment on Chandrayaan-1 satellite
Published in Advances in space research (01-09-2011)“…The RADiatiOn Monitor (RADOM) is a miniature dosimeter-spectrometer that flew onboard the Chandrayaan-1 lunar mission in order to monitor the local radiation…”
Get full text
Journal Article -
7
Relativistic electron fluxes and dose rate variations during April–May 2010 geomagnetic disturbances in the R3DR data on ISS
Published in Advances in space research (15-07-2012)“…Space radiation has been monitored successfully using the Radiation Risks Radiometer-Dosimeter (R3D) installed at the ESA EXPOSE-R (R3DR) facility outside of…”
Get full text
Journal Article -
8
Pre-engineering spaceflight validation of environmental models and the 2005 HZETRN simulation code
Published in Advances in space research (2007)“…The HZETRN code has been identified by NASA for engineering design in the next phase of space exploration highlighting a return to the Moon in preparation for…”
Get full text
Journal Article -
9
Proposal for a new radiation dose control system for future manned space flights
Published in Acta astronautica (01-10-1995)“…Radiation risk on a future long-duration manned space mission appears to be one of the basic factors in planning and designing the mission. Since 1988…”
Get full text
Journal Article -
10
Time serial analysis of the induced LEO environment within the ISS 6A
Published in Advances in space research (2007)“…Anisotropies in the low Earth orbit (LEO) radiation environment were found to influence the thermoluminescence detectors (TLD) dose within the (International…”
Get full text
Journal Article -
11
Simultaneous investigation of galactic cosmic rays on aircrafts and on International Space Station
Published in Advances in space research (2005)“…The galactic cosmic ray component of the space radiation environments at aircraft altitudes and on the International Space Station (ISS) were measured by…”
Get full text
Journal Article -
12
Analysis of the cyclotron facility calibration and aircraft dosimetry results from the liulin-3M instrument
Published in Advances in space research (01-01-2003)“…The LIULIN-3M instrument is a further development of the LIULIN dosimeter-radiometer, used on the MIR space station during the 1988–1994 time period. The…”
Get full text
Journal Article -
13
Solar cycle variations of MIR radiation environment as observed by the LIULIN dosimeter
Published in Radiation measurements (01-06-1999)“…Measurements on board the MIR space station by the Bulgarian-Russian dosimeter LIULIN have been used to study the solar cycle variations of the radiation…”
Get full text
Journal Article -
14
Tissue equivalent detector data obtained recently on Mir space station. Comparison with Solid State Detector data
Published in Advances in space research (1996)“…Tissue equivalent and Solid State Detector (SSD) measurements of the radiation environment inside the Mir space station were performed during the Antares…”
Get full text
Journal Article -
15
New results for the space radiation environment of mir space station obtained by liulin dosimeter-radiometer. Comparison with let spectrometer nausicaa
Published in Acta astronautica (01-10-1995)“…Since 1988 high sensitivity semiconductor dosimeter-radiometer “Liulin” worked on board of MIR space station. Device measured the absorbed dose rate and the…”
Get full text
Journal Article -
16
"Mir" radiation dosimetry results during the solar proton events in September-October 1989
Published in Advances in space research (1992)“…Using data from dosimetry-radiometry system "Liulin" on board of "Mir"-space station the particle flux and doserate during September-October, 1989 has been…”
Get more information
Journal Article