Search Results - "Tomaru, T."

Refine Results
  1. 1

    An infrared measurement of chemical desorption from interstellar ice analogues by Oba, Y., Tomaru, T., Lamberts, T., Kouchi, A., Watanabe, N.

    Published in Nature astronomy (01-03-2018)
    “…In molecular clouds at temperatures as low as 10 K, all species except hydrogen and helium should be locked in the heterogeneous ice on dust grain surfaces…”
    Get full text
    Journal Article
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7

    Mechanical quality factor of a cryogenic sapphire test mass for gravitational wave detectors by Uchiyama, T., Tomaru, T., Tobar, M.E., Tatsumi, D., Miyoki, S., Ohashi, M., Kuroda, K., Suzuki, T., Sato, N., Haruyama, T., Yamamoto, A., Shintomi, T.

    Published in Physics letters. A (04-10-1999)
    “…A sapphire cylinder, of 100 mm diameter and 60 mm length, was suspended on a pair of sapphire fibers to simulate a mirror for a cryogenic laser interferometric…”
    Get full text
    Journal Article
  8. 8
  9. 9
  10. 10
  11. 11

    Maximum heat transfer along a sapphire suspension fiber for a cryogenic interferometric gravitational wave detector by Tomaru, T, Suzuki, T, Uchiyama, T, Yamamoto, A, Shintomi, T, Taylor, C.T, Yamamoto, K, Miyoki, S, Ohashi, M, Kuroda, K

    Published in Physics letters. A (26-08-2002)
    “…We have shown experimentally that the thermal conductivity of a sapphire fiber, which is used as a suspension and thermal conductor of mirrors in a cryogenic…”
    Get full text
    Journal Article
  12. 12

    Cryogenic cooling of a sapphire mirror-suspension for interferometric gravitational wave detectors by Uchiyama, T., Tatsumi, D., Tomaru, T., Tobar, M.E., Kuroda, K., Suzuki, T., Sato, N., Yamamoto, A., Haruyama, T., Shintomi, T.

    Published in Physics letters. A (01-06-1998)
    “…The sensitivity of large-scale interferometric gravitational wave detectors currently under construction will be limited by thermal noise in the…”
    Get full text
    Journal Article
  13. 13

    Test Results of Superconducting Magnets for the J-PARC Neutrino Beam Line by Okamura, T., Sasaki, K.-i., Tomaru, T., Ajima, Y., Ogitsu, T., Kimura, N., Iida, M., Ohhata, H., Sugawara, S., Tanaka, K.-i., Nakamoto, T., Higashi, N., Makida, Y., Araoka, O., Kasami, K., Suzuki, S., Suzuki, T., Terashima, A., Yamamoto, A.

    “…Fabrication and cold tests of 32 superconducting combined function magnets including 4 backup magnets for the J-PARC neutrino have been completed. All the…”
    Get full text
    Journal Article Conference Proceeding
  14. 14

    Mechanical quality factor of a sapphire fiber at cryogenic temperatures by Uchiyama, T, Tomaru, T, Tatsumi, D, Miyoki, S, Ohashi, M, Kuroda, K, Suzuki, T, Yamamoto, A, Shintomi, T

    Published in Physics letters. A (04-09-2000)
    “…A mechanical quality factor of 1.1×10 7 was obtained for the 199 Hz bending vibrational mode in a monocrystalline sapphire fiber at 6 K. Consequently, we…”
    Get full text
    Journal Article
  15. 15

    Magnetic Field Measurement System in Superconducting Combined Function Magnets for the J-PARC Neutrino Beam Line by Sasaki, K., Tomaru, T., Ajima, Y., Ogitsu, T., Araoka, O., Higashi, N., Iida, M., Kasami, K., Kimura, N., Makida, Y., Nakamoto, T., Ohhata, H., Okamura, T., Sugawara, S., Tanaka, K., Yamamoto, A.

    “…Magnetic field measurements have been performed for the first full-scale magnet system assembled with the cryostat for the J-PARC proton beam line of neutrino…”
    Get full text
    Journal Article Conference Proceeding
  16. 16

    Test Results of Superconducting Combined Function Magnets for the J-PARC Neutrino Beam Line by Sasaki, K.-I.., Nakamoto, T.., Kimura, N.., Tomaru, T.., Ogitsu, T.., Higashi, N.., Ajima, Y.., Araoka, O.., Iida, M.., Kasami, K.., Makida, Y.., Ohhata, H.., Okamura, T.., Sugawara, S.., Tanaka, K.-I.., Terashima, A.., Yamamoto, A.., Obana, T.., Okada, Y.., Minato, T.., Ichihara, T..

    “…Superconducting combined function magnets for the J-PARC (Japan Proton Accelerator Research Complex) neutrino experiment have been successfully developed at…”
    Get full text
    Journal Article Conference Proceeding
  17. 17

    Application of diamond-like Carbon (DLC) coatings for gravitational wave detectors by Takahashi, R., Saito, Y., Sato, Y., Kubo, T., Tomaru, T., Tokunari, M., Sumiya, T., Takasugi, K., Naito, Y.

    Published in Vacuum (19-03-2004)
    “…A laser interferometer gravitational wave detector requires an ultra high vacuum in the tubes in which the laser beams pass. To avoid noise due to scattered…”
    Get full text
    Journal Article
  18. 18
  19. 19

    Haemodynamic and splanchnic organ blood-flow responses to hypotension induced by the calcitonin gene-related peptide and sodium nitroprusside in dogs by Takeda, S, Tomaru, T

    Published in European journal of anaesthesiology (01-12-2002)
    “…To elucidate the effects of various degrees of hypotension induced by the calcitonin gene-related peptide (CGRP) on the splanchnic circulation, we investigated…”
    Get more information
    Journal Article
  20. 20

    Development of a prototype of Superconducting combined function magnet for the 50 GeV proton beam line for the J-PARC neutrino experiment by Nakamoto, T., Higashi, N., Ogitsu, T., Terashima, A., Ajima, Y., Anerella, M., Gupta, R., Iwamoto, Y., Kimura, N., Makida, Y., Obana, T., Ohhata, H., Parker, B., Sasaki, K., Tanaka, K., Tomaru, T., Wanderer, P., Yamamoto, A.

    “…Superconducting combined function magnets will be utilized for the 50 GeV, 750 kW proton beam line for the J-PARC neutrino experiment and an R&D program has…”
    Get full text
    Journal Article Conference Proceeding