Search Results - "Tomarchio, E"

Refine Results
  1. 1

    Risk assessment of component failure modes and human errors using a new FMECA approach: application in the safety analysis of HDR brachytherapy by Giardina, M, Castiglia, F, Tomarchio, E

    Published in Journal of radiological protection (01-12-2014)
    “…Failure mode, effects and criticality analysis (FMECA) is a safety technique extensively used in many different industrial fields to identify and prevent…”
    Get more information
    Journal Article
  2. 2

    On the thermal-hydraulic performances of the DEMO divertor cassette body cooling circuit equipped with a liner by Di Maio, P.A., Forte, R., Gaglio, R., You, J.H., Mazzone, G., Tomarchio, E., Vallone, E.

    Published in Fusion engineering and design (01-07-2020)
    “…•Assessment of the steady-state thermal-hydraulic performances of the DEMO Divertor Cassette Body (CB).•Adoption of a theoretical-numerical approach based on…”
    Get full text
    Journal Article
  3. 3

    Preliminary design of the top cap of DEMO Water-Cooled Lithium Lead breeding blanket segments by Forte, R., Arena, P., Bongiovì, G., Catanzaro, I., Del Nevo, A., Di Maio, P.A., Tomarchio, E., Vallone, E.

    Published in Fusion engineering and design (01-12-2020)
    “…•A preliminary design of the Top Cap of the WCLL BB outboard central segment has been developed.•A specific cooling circuit with the aim of removing the heat…”
    Get full text
    Journal Article
  4. 4

    A Review of Healthcare Failure Mode and Effects Analysis (HFMEA) in Radiotherapy by Giardina, M, Cantone, M.C, Tomarchio, E, Veronese, I

    Published in Health physics (1958) (01-10-2016)
    “…ABSTRACTThis paper presents a review of risk analyses in radiotherapy (RT) processes carried out by using Healthcare Failure Mode Effect Analysis (HFMEA)…”
    Get full text
    Journal Article
  5. 5

    Coincidence-summing correction equations in gamma-ray spectrometry with p-type HPGedetectors by Tomarchio, E., Rizzo, S.

    “…Equations to compute γ−γ and γ−X K coincidence-summing corrections in gamma-ray spectrometry with p-type HPGe detectors are reported. For point sources only…”
    Get full text
    Journal Article
  6. 6

    Radionuclide concentrations in air particulate at Palermo (Italy) following Fukushima accident by Rizzo, S, Tomarchio, E

    Published in Radiation protection dosimetry (01-03-2013)
    “…Following the Fukushima accident, a series of samplings were carried out with a daily frequency to detect the arrival of radioactive contamination in air at…”
    Get full text
    Journal Article
  7. 7

    A radiometric and petrographic interpretation of discrepancies on uranium content in samples collected at Alte Madonie Mounts region (Sicily, Italy) by Lanzo, G., Rizzo, S., Tomarchio, E.

    Published in Journal of environmental radioactivity (01-03-2014)
    “…The main goal of this work is to evaluate a correlation between anomalous Uranium (U) content and petrographic features of some soil and rock samples collected…”
    Get full text
    Journal Article
  8. 8

    Numerical expressions for the computation of coincidence-summing correction factors in γ-ray spectrometry with HPGe detectors by Rizzo, S., Tomarchio, E.

    Published in Applied radiation and isotopes (01-04-2010)
    “…Numerical expressions to compute γ–γ and γ–X K coincidence summing corrections were deduced by using a suitable computer program and a matrix representation of…”
    Get full text
    Journal Article
  9. 9

    A radiometric and petrographic approach to risk assessment at Alte Madonie Mounts region (Sicily, Italy) by Lanzo, G, Rizzo, S, Tomarchio, E

    Published in Radiation protection dosimetry (01-03-2014)
    “…The main goal of this work was to assess the radiological hazard at Alte Madonie Mounts region (north-central Sicily, Italy) in response to rumours of an…”
    Get full text
    Journal Article
  10. 10

    Neutron ESR dosimetry through ammonium tartrate with low Gd content by Marrale, M, Brai, M, Longo, A, Panzeca, S, Tranchina, L, Tomarchio, E, Parlato, A, Buttafava, A, Dondi, D

    Published in Radiation protection dosimetry (01-06-2014)
    “…This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors…”
    Get full text
    Journal Article
  11. 11

    Virtual point detector: Application to coincidence-summing correction in gamma-ray spectrometry by Rizzo, S., Tomarchio, E.

    Published in Applied radiation and isotopes (01-07-2010)
    “…The use of an efficiency transfer method based on the virtual point detector approximation to evaluate coincidence-summing correction values for point and…”
    Get full text
    Journal Article
  12. 12

    Risk analysis using fuzzy set theory of the accidental exposure of medical staff during brachytherapy procedures by Castiglia, F, Giardina, M, Tomarchio, E

    Published in Journal of radiological protection (01-03-2010)
    “…Using fuzzy set theory, this paper presents results from risk analyses that explore potential exposure of medical operators working in a high dose rate…”
    Get more information
    Journal Article
  13. 13

    EPR/alanine pellets with low Gd content for neutron dosimetry by Marrale, M, Brai, M, Longo, A, Panzeca, S, Carlino, A, Tranchina, L, Tomarchio, E, Parlato, A, Buttafava, A, Dondi, D, Zeffiro, A

    Published in Radiation protection dosimetry (01-10-2014)
    “…This paper reports on results obtained by electron paramagnetic resonance (EPR) measurements and Monte Carlo (MC) simulation on a blend of alanine added with…”
    Get full text
    Journal Article
  14. 14

    A chamber to test the response of radon detectors to changing environmental conditions by Compagno, A, Parlato, A, Rizzo, S, Tomarchio, E

    Published in Radiation protection dosimetry (01-05-2011)
    “…Radon risk assessment is carried out by means of accurate measurements with active or passive instrumentation. All radon detectors must be calibrated and…”
    Get full text
    Journal Article
  15. 15

    Fuzzy modelling of HEART methodology: application in safety analyses of accidental exposure in irradiation plants by Casamirra, M., Castiglia, F., Giardina, M., Tomarchio, E.

    Published in Radiation effects and defects in solids (01-05-2009)
    “…This study refers to the results obtained by Fuzzy Fault Tree analyses of accidental scenarios that entail the potential exposure of operators working in…”
    Get full text
    Journal Article
  16. 16

    MCNP5 modelling of HPGe detectors for efficiency evaluation in [gamma]-ray spectrometry by Maurotto, A, Rizzo, S, Tomarchio, E

    Published in Radiation effects and defects in solids (01-05-2009)
    “…A modelling of HPGe detectors was performed through simulation with the MCNP5 Monte Carlo code. The simulation results concerning the values of the main…”
    Get full text
    Journal Article
  17. 17

    Novel epoxy formulations for high energy radiation curable composites by Spadaro, G., Calderaro, E., Tomarchio, E., Dispenza, C.

    “…It has been widely recognised that high energy radiation can be effectively applied to the cure of epoxy resins in applications as composite matrices or…”
    Get full text
    Journal Article
  18. 18

    Silicon dosimeters based on Floating Gate Sensor: design, implementation and characterization by Gatti, U., Calligaro, C., Parlato, A., Tomarchio, E. A. G., Pikhay, E., Roizin, Y.

    “…A rad-hard monolithic dosimeter has been implemented and characterized in a standard 180 nm CMOS technology. The radiation sensor (C-sensor) is based on a…”
    Get full text
    Conference Proceeding
  19. 19

    Neutron and gamma-ray radiation fields characterisation in a 241Am–Be irradiator in view of its use as research testing too by Marchese, N, Fiore, D, Cottone, D, Parlato, A, Tomarchio, E

    “…A neutron irradiation facility based on four 241Am–Be sources, each one with an activity of 111 GBq, placed in Plexiglas pipes inside a tank filled with water…”
    Get full text
    Journal Article
  20. 20

    Neutron and gamma-ray radiation fields characterisation in a 241Am–Be irradiator in view of its use as research testing tool by Marchese, N., Fiore, D., Cottone, D., Parlato, A., Tomarchio, E.

    “…A neutron irradiation facility based on four 241Am–Be sources, each one with an activity of 111 GBq, placed in Plexiglas pipes inside a tank filled with water…”
    Get full text
    Journal Article