Search Results - "Tielliu, Ignace F"
-
1
Quantification of abdominal aortic calcification: Inherent measurement errors in current computed tomography imaging
Published in PloS one (28-02-2018)“…Quantification software for coronary calcification is often used to measure abdominal aortic calcification on computed tomography (CT) images. However, there…”
Get full text
Journal Article -
2
The relevance of aortic endograft prosthetic infection
Published in Journal of vascular surgery (01-08-2011)“…Background Vascular prosthetic graft infection is a severe complication after open aortic aneurysm repair. Reports of infected endografts are scarce. General…”
Get full text
Journal Article -
3
Endograft Sizing for Endovascular Aortic Repair and Incidence of Endoleak Type 1A
Published in PloS one (30-06-2016)“…In endovascular aortic aneurysm repair (EVAR), proximal type 1A endoleaks can occur as a result of hostile neck anatomy or over- or undersizing of the…”
Get full text
Journal Article -
4
Mid-term results of endovascular aneurysm repair with branched and fenestrated endografts
Published in Journal of vascular surgery (01-07-2006)“…The technique of fenestrated and branched endovascular aneurysm repair (EVAR) has been used for the treatment a variety of aortic aneurysms. Although…”
Get full text
Journal Article Conference Proceeding -
5
Stent fractures in the Hemobahn/Viabahn stent graft after endovascular popliteal aneurysm repair
Published in Journal of vascular surgery (01-06-2010)“…Objective During the last decade, endovascular repair of popliteal artery aneurysms (PAAs) has become a valid alternative to open repair. This study analyzes…”
Get full text
Journal Article -
6
Comparison of Modified Chandler, Roller Pump, and Ball Valve Circulation Models for In Vitro Testing in High Blood Flow Conditions: Application in Thrombogenicity Testing of Different Materials for Vascular Applications
Published in International Journal of Biomaterials (01-01-2012)“…Three different models, a modified Chandler loop, roller pump, and a new ball valve model (Hemobile), were compared with regard to intrinsic damage of blood…”
Get full text
Journal Article -
7
Endovascular treatment of traumatic thoracic aortic lesions: a systematic review and meta-analysis
Published in Journal of cardiovascular surgery (01-02-2019)“…To provide an overview of the experience of endovascular treatment for traumatic thoracic aortic lesions (TTAL). Thoracic aortic injury secondary to…”
Get full text
Journal Article -
8
Conservative treatment of vascular prosthetic graft infection is associated with high mortality
Published in The American journal of surgery (01-07-2010)“…Abstract Background The aim of this study was to identify patient-related and/or disease-related factors that influence outcomes in patients with vascular…”
Get full text
Journal Article -
9
Mortality of ruptured abdominal aortic aneurysm treated with open or endovascular repair
Published in Journal of vascular surgery (01-12-2008)“…Objectives The study defined the selection criteria used for treatment of ruptured abdominal aortic aneurysms (RAAAs) and reviewed results during a 5-year…”
Get full text
Journal Article -
10
The upside down Gore Excluder contralateral leg without extracorporeal predeployment for aortic or iliac aneurysm exclusion
Published in Journal of vascular surgery (01-06-2011)“…Endovascular techniques, including branched devices to preserve the internal iliac artery are evolving rapidly, but in cases in which the diameter of the…”
Get full text
Journal Article -
11
Fenestrated and branched endograft repair of juxtarenal aneurysms after previous open aortic reconstruction
Published in Journal of vascular surgery (01-06-2009)“…Objective Para-anastomotic aortic aneurysms and progressive aneurysmal degeneration of the aorta after previous open aortic reconstruction pose a challenging…”
Get full text
Journal Article -
12
Type B Aortic Dissection After the Use of Tadalafil
Published in The Annals of thoracic surgery (01-02-2012)“…A 63-year-old male patient with a type B aortic dissection after the use of tadalafil, a phosphodiesterase type 5 inhibitor, is presented. The possible role of…”
Get full text
Journal Article -
13
Mycotic Abdominal Aortic and Iliac Aneurysm Caused by Streptococcus equi Subspecies zooepidemicus Bacteremia
Published in Aorta (Stamford, Conn.) (01-12-2019)“…Abstract This report describes a case of a taxidermist who presented with sepsis and excruciating back pain a few weeks after contact with a deceased horse…”
Get full text
Journal Article -
14
Effectiveness of treatment for octogenarians with acute abdominal aortic aneurysm
Published in Journal of vascular surgery (01-04-2011)“…Objective: To investigate whether advanced age may be a reason to refrain from treatment in patients with an acute abdominal aortic aneurysm (AAAA). Methods:…”
Get full text
Journal Article -
15
Long-term outcome of endovascular popliteal artery aneurysm repair
Published in Journal of vascular surgery (01-06-2018)“…The position of endovascular treatment in the algorithm of popliteal artery aneurysm (PAA) repair is still a matter of debate. Although several studies have…”
Get full text
Journal Article -
16
Hybrid endograft solution for complex iliac anatomy: Zenith body and Excluder limbs
Published in Vascular (01-06-2010)“…The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook…”
Get more information
Journal Article -
17
A modified technique for Gore Excluder limb deployment in difficult iliac anatomy during endovascular abdominal aortic aneurysm repair
Published in Vascular (01-02-2015)“…Complex iliac anatomy including extreme tortuosity constitutes a relative contraindication for endovascular abdominal aortic aneurysm repair with additional…”
Get more information
Journal Article -
18
A modified technique for iliac artery branched endografting using a “tromboned” sheath
Published in Journal of vascular surgery (01-12-2008)“…The iliac branched device (IBD) is the only totally endovascular option to preserve flow to the internal iliac artery for the treatment of aorto-iliac or…”
Get full text
Journal Article -
19
Is emergency endovascular aneurysm repair associated with higher secondary intervention risk at mid-term follow-up?
Published in Journal of vascular surgery (01-12-2006)“…The study assessed mid-term outcome of emergency endovascular repair for acute infrarenal abdominal aortic aneurysms, with special attention to secondary…”
Get full text
Journal Article -
20
Three-Dimensional Geometric Analysis of Viabahn VBX Bridging Stent Grafts in Fenestrated Endovascular Aortic Repair: A Multicenter, Retrospective Cohort Study
Published in Journal of endovascular therapy (06-05-2024)“…The primary aim of this study was to assess the 3-dimensional flare geometry of the Gore Viabahn VBX balloon-expandable covered stent (BECS) after fenestrated…”
Get full text
Journal Article