Dialyzer reuse impact on dialyzer efficiency, patient morbidity and mortality and cost effectiveness
Since the introduction of dialyzer reuse more than three decades ago, several studies have reported its safety, efficacy and cost effectiveness. Reuse of hemodialyzer was prospectively studied in ten chronic hemodialysis (HD) patients recruited from the renal unit, the King Khalid University Hospita...
Saved in:
Published in: | Saudi journal of kidney diseases and transplantation Vol. 12; no. 3; pp. 305 - 311 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Riyadh, Saudi Arabia
Saudi Center for Organ Transplantation
01-07-2001
Wolters Kluwer Medknow Publications |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Since the introduction of dialyzer reuse more than three decades ago, several
studies have reported its safety, efficacy and cost effectiveness. Reuse of hemodialyzer was
prospectively studied in ten chronic hemodialysis (HD) patients recruited from the renal
unit, the King Khalid University Hospital, Riyadh, Saudi Arabia, for three months. During
the study period, 66 dialyzers were used for 408 sessions of HD, with a mean reuse of 6.2 5.3
episodes per dialyser, the mean of maximum reuse episodes being 13.7 8.0. The urea reduction
ratio was maintained between 73 5 % at baseline to 71.2 9.03 % (p = 0.53) at the
maximum reuse. Similarly phosphate reduction with each HD session was maintained ;
mean decrease in phosphate levels was 0.67 mmol / L. Significant increase in heparin
requirement was noted ; however, the risk of bleeding was not increased. Hematocrit levels
increased from 30.4 4.1 % to 33.2 3.6 % at the end of the study (p = 0.6). Albumin leak in
dialysate decreased with each reuse ; baseline 8.27 7.93 mg / L to 2.8 0.4 mg / L at
maximum reuse (p = 0.04). Serum albumin levels remained stable. No short-term adverse
effects on patients' morbidity and mortality were noted. Total cost savings of 53 % was
achieved with the reuse of dialyzers, excluding capital equipment used for preparation for
reuse. In conclusion, dialyzer reuse seems to be safe and may provide an economical and
efficient dialysis. Studies involving larger number of patients is required to validate this
observation. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1319-2442 2320-3838 |