Search Results - "Ter Haar Romeny, B M"

Refine Results
  1. 1

    Optimal Short-Time Acquisition Schemes in High Angular Resolution Diffusion-Weighted Imaging by Prčkovska, V., Achterberg, H. C., Bastiani, M., Pullens, P., Balmashnova, E., ter Haar Romeny, B. M., Vilanova, Anna, Roebroeck, A.

    “…This work investigates the possibilities of applying high-angular-resolution-diffusion-imaging- (HARDI-) based methods in a clinical setting by investigating…”
    Get full text
    Journal Article
  2. 2

    Visualization of 4D Blood-Flow Fields by Spatiotemporal Hierarchical Clustering by van Pelt, R. F. P., Jacobs, S. S. A. M., ter Haar Romeny, B. M., Vilanova, A.

    Published in Computer graphics forum (01-06-2012)
    “…Advancements in the acquisition and modeling of flow fields result in unsteady volumetric flow fields of unprecedented quality. An important example is found…”
    Get full text
    Journal Article
  3. 3

    Automated detection of cerebral microbleeds in patients with Traumatic Brain Injury by van den Heuvel, T L A, van der Eerden, A W, Manniesing, R, Ghafoorian, M, Tan, T, Andriessen, T M J C, Vande Vyvere, T, van den Hauwe, L, Ter Haar Romeny, B M, Goraj, B M, Platel, B

    Published in NeuroImage clinical (01-01-2016)
    “…In this paper a Computer Aided Detection (CAD) system is presented to automatically detect Cerebral Microbleeds (CMBs) in patients with Traumatic Brain Injury…”
    Get full text
    Journal Article
  4. 4

    Illustrative uncertainty visualization of DTI fiber pathways by Brecheisen, R., Platel, B., ter Haar Romeny, B. M., Vilanova, A.

    Published in The Visual computer (01-04-2013)
    “…Diffusion Tensor Imaging (DTI) and fiber tracking provide unique insight into the 3D structure of fibrous tissues in the brain. However, the output of fiber…”
    Get full text
    Journal Article
  5. 5

    The use of a reference tissue arterial input function with low-temporal-resolution DCE-MRI data by Heisen, M, Fan, X, Buurman, J, van Riel, N A W, Karczmar, G S, ter Haar Romeny, B M

    Published in Physics in medicine & biology (21-08-2010)
    “…Pharmacokinetic modeling is a promising quantitative analysis technique for cancer diagnosis. However, diagnostic dynamic contrast-enhanced magnetic resonance…”
    Get more information
    Journal Article
  6. 6

    Quantification of atherosclerotic plaque components using in vivo MRI and supervised classifiers by Hofman, J.M.A., Branderhorst, W.J., ten Eikelder, H.M.M., Cappendijk, V.C., Heeneman, S., Kooi, M.E., Hilbers, P.A.J., ter Haar Romeny, B.M.

    Published in Magnetic resonance in medicine (01-04-2006)
    “…In this work we aimed to study the possibility of using supervised classifiers to quantify the main components of carotid atherosclerotic plaque in vivo on the…”
    Get full text
    Journal Article
  7. 7

    Multiscale Segmentation of Three-Dimensional MR Brain Images by Niessen, Wj, Vincken, Kl, Weickert, J, Romeny, Bm Ter; Haar, Viergever, Ma

    “…Segmentation of MR brain images using intensity values is severely limited owing to field inhomogeneities, susceptibility artifacts and partial volume effects…”
    Get full text
    Journal Article
  8. 8

    Active shape model segmentation with optimal features by van Ginneken, B., Frangi, A.F., Staal, J.J., ter Haar Romeny, B.M., Viergever, M.A.

    Published in IEEE transactions on medical imaging (01-08-2002)
    “…An active shape model segmentation scheme is presented that is steered by optimal local features, contrary to normalized first order derivative profiles, as in…”
    Get full text
    Journal Article
  9. 9

    Automatic segmentation of lung fields in chest radiographs by van Ginneken, Bram, ter Haar Romeny, Bart M.

    Published in Medical physics (Lancaster) (01-10-2000)
    “…The delineation of important structures in chest radiographs is an essential preprocessing step in order to automatically analyze these images, e.g., for…”
    Get full text
    Journal Article
  10. 10

    Automatic detection of abnormalities in chest radiographs using local texture analysis by van Ginneken, B., Katsuragawa, S., ter Haar Romeny, B.M., Kunio Doi, Viergever, M.A.

    Published in IEEE transactions on medical imaging (01-02-2002)
    “…A fully automatic method is presented to detect abnormalities in frontal chest radiographs which are aggregated into an overall abnormality score. The method…”
    Get full text
    Journal Article
  11. 11

    Optic flow based on multi-scale anchor point movement and discontinuity-preserving regularization by van Dorst, P.A.G., Janssen, B.J., Florack, L.M.J., ter Haar Romeny, B.M.

    Published in Pattern recognition (01-09-2011)
    “…We introduce a new method to determine the flow field of an image sequence using multi-scale anchor points. These anchor points manifest themselves in the…”
    Get full text
    Journal Article
  12. 12

    A novel 3D multi-scale lineness filter for vessel detection by Bennink, H E, van Assen, H C, Streekstra, G J, ter Wee, R, Spaan, J A E, ter Haar Romeny, B M

    “…The branching pattern and geometry of coronary microvessels are of high interest to understand and model the blood flow distribution and the processes of…”
    Get more information
    Journal Article
  13. 13

    Interactive Fibre Structure Visualization of the Heart by Peeters, T. H. J. M., Vilanova, A., Romeny, B. M. ter Haar

    Published in Computer graphics forum (01-12-2009)
    “…The heart consists of densely packed muscle fibres. The orientation of these fibres can be acquired by using Diffusion Tensor Imaging (DTI) ex vivo. A good way…”
    Get full text
    Journal Article
  14. 14

    Relation between location of a motor unit in the human biceps brachii and its critical firing levels for different tasks by ter Haar Romeny, B M, van der Gon, J J, Gielen, C C

    Published in Experimental neurology (01-09-1984)
    “…Critical firing levels (CFLs) of single motor units (MUs) in the long head of the human biceps brachii muscle were determined in combinations of two isometric…”
    Get more information
    Journal Article
  15. 15

    Pharmacokinetic models in clinical practice: What model to use for DCE-MRI of the breast? by Litjens, G J S, Heisen, M, Buurman, J, ter Haar Romeny, B M

    “…Pharmacokinetic modeling is increasingly used in DCE-MRI high risk breast cancer screening. Several models are available. The most common models are the…”
    Get full text
    Conference Proceeding
  16. 16

    3D saddle point detection and applications in cardiac imaging by Fuster, A., van Pelt, R. F. P., Fick, R. H. J., Claassen, G., ter Haar Romeny, B. M., van Assen, H. C., Florack, L. M. J.

    “…We investigate saddle points in 3D cardiac images. We do so by improving a critical point detection algorithm, the 3D winding number, or Poincaré index. We…”
    Get full text
    Conference Proceeding
  17. 17

    Geodesic deformable models for medical image analysis by Niessen, W.J., Romeny, B.M.T.H., Viergever, M.A.

    Published in IEEE transactions on medical imaging (01-08-1998)
    “…In this paper implicit representations of deformable models for medical image enhancement and segmentation are considered. The advantage of implicit models…”
    Get full text
    Journal Article
  18. 18

    Discrimination of the intravascular lumen and dissections in a single 30-MHz US image: use of "confounding" blood backscatter to advantage by Pasterkamp, G, van der Heiden, M S, Post, M J, Ter Haar Romeny, B M, Mali, W P, Borst, C

    Published in Radiology (01-06-1993)
    “…At 30-MHz intravascular ultrasound, the high-intensity backscatter of blood confounds discrimination of the intravascular lumen from the arterial wall. The…”
    Get more information
    Journal Article
  19. 19

    Cardiac left atrium CT image segmentation for ablation guidance by Koppert, M M J, Rongen, P M J, Prokop, M, ter Haar Romeny, B M, van Assen, H C

    “…Catheter ablation is an increasingly important curative procedure for atrial fibrillation. Knowledge of the local wall thickness is essential to determine the…”
    Get full text
    Conference Proceeding
  20. 20

    Behaviour of motor units of human arm muscles: differences between slow isometric contraction and relaxation by Denier van der Gon, J J, ter Haar Romeny, B M, van Zuylen, E J

    Published in The Journal of physiology (01-02-1985)
    “…The behaviour of motor units in the m. biceps brachii (long head), in the m. brachialis and in the m. supinator during slow isometric contraction and…”
    Get full text
    Journal Article