Search Results - "Tatkowski, G."
-
1
High gradient performance and quench behavior of a verification cryomodule for a high energy continuous wave linear accelerator
Published in Physical review. Accelerators and beams (01-04-2022)“…An eight-cavity, 1.3 GHz, SLAC linac coherent light source II High Energy cryomodule was assembled and tested at Fermilab to verify performance before the…”
Get full text
Journal Article -
2
Thermal conductance measurements of bolted copper joints for SuperCDMS
Published in Cryogenics (Guildford) (01-09-2015)“…•Joint thermal conductance across bolted copper to copper connections has been tested from 60mK to 26K.•Surfaces passivated with citric acid were tested as an…”
Get full text
Journal Article -
3
Thermal conductance measurements of bolted copper joints for SuperCDMS
Published in Cryogenics (Guildford) (28-04-2015)“…Joint thermal conductance testing has been undertaken for bolted copper to copper connections from 60 mK to 26 K. This testing was performed to validate an…”
Get full text
Journal Article -
4
Fabrication and installation of the Mu2e cryogenic distribution system
Published 25-01-2022“…The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons…”
Get full text
Journal Article -
5
LCLS-II-HE verification cryomodule high gradient performance and quench behavior
Published 27-10-2021“…An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were…”
Get full text
Journal Article