Search Results - "Taniwaki, Masanori"
-
1
Mechanisms of Very Late Drug-Eluting Stent Thrombosis Assessed by Optical Coherence Tomography
Published in Circulation (New York, N.Y.) (16-02-2016)“…BACKGROUND—The pathomechanisms underlying very late stent thrombosis (VLST) after implantation of drug-eluting stents (DES) are incompletely understood. Using…”
Get full text
Journal Article -
2
Effect of high-intensity statin therapy on atherosclerosis in non-infarct-related coronary arteries (IBIS-4): a serial intravascular ultrasonography study
Published in European heart journal (21-02-2015)“…The effect of long-term high-intensity statin therapy on coronary atherosclerosis among patients with acute ST-segment elevation myocardial infarction (STEMI)…”
Get full text
Journal Article -
3
4-Year Clinical Outcomes and Predictors of Repeat Revascularization in Patients Treated With New-Generation Drug-Eluting Stents
Published in Journal of the American College of Cardiology (29-04-2014)“…Objectives The aim of the study was to investigate 4-year outcomes and predictors of repeat revascularization in patients treated with the Resolute…”
Get full text
Journal Article -
4
The association between in-stent neoatherosclerosis and native coronary artery disease progression: a long-term angiographic and optical coherence tomography cohort study
Published in European heart journal (21-08-2015)“…The purpose of the present study was to investigate the relationship between in-stent neoatherosclerosis (NA) and native atherosclerosis progression of…”
Get full text
Journal Article -
5
Ex Vivo Assessment of Vascular Response to Coronary Stents by Optical Frequency Domain Imaging
Published in JACC. Cardiovascular imaging (2012)“…Objectives This study sought to examine the capability of optical frequency domain imaging (OFDI) to characterize various morphological and histological…”
Get full text
Journal Article -
6
Effects of Mokuboito, a Japanese Kampo medicine, on symptoms in patients hospitalized for acute decompensated heart failure – A prospective randomized pilot study
Published in Journal of cardiology (01-11-2019)“…•Mokuboito has been traditionally used to treat patients with heart failure (HF).•This randomized study showed Mokuboito significantly improved HF…”
Get full text
Journal Article -
7
Discordance in the diagnostic assessment of vulnerable plaques between radiofrequency intravascular ultrasound versus optical coherence tomography among patients with acute myocardial infarction: insights from the IBIS-4 study
Published in The International Journal of Cardiovascular Imaging (01-10-2021)“…We aimed to evaluate the diagnostic agreement between radiofrequency (RF) intravascular ultrasound (IVUS) and optical coherence tomography (OCT) for thin-cap…”
Get full text
Journal Article -
8
Serial Optical Coherence Tomography Assessment of Coronary Atherosclerosis and Long-Term Clinical Outcomes
Published in Journal of the American Heart Association (05-11-2024)“…The impact of high-risk coronary artery plaques identified using optical coherence tomography on late luminal narrowing and clinical events remains poorly…”
Get full text
Journal Article -
9
The fasting 13C-glucose breath test is a more sensitive evaluation method for diagnosing hepatic insulin resistance as a cardiovascular risk factor than HOMA-IR
Published in Clinica chimica acta (01-01-2020)“…•FGBT is a noninvasive and simple test for assessing hepatic IR.•The hepatic IR was evaluated with the value of C120 in the FGBT.•We examined the C120 and the…”
Get full text
Journal Article -
10
TCT-455 Angiographic derived Endothelial Shear Stress: a new predictor of atherosclerotic disease progression
Published in Journal of the American College of Cardiology (31-10-2017)“…There is little evidence, however, about the predictive value of the ESS estimated in models derived from three-dimensional quantitative coronary angiography…”
Get full text
Journal Article -
11
TCT-451 Shear stress analysis in multimodality imaging a sub-analysis of IBIS 4 study
Published in Journal of the American College of Cardiology (31-10-2017)“…The coronary artery anatomy was reconstructed by fusing IVUS and X-ray imaging data, blood flow simulation was performed in the baseline models and the…”
Get full text
Journal Article -
12
Impact of Patient and Lesion Complexity on Long-Term Outcomes Following Coronary Revascularization with New-Generation Drug-Eluting Stents
Published in The American journal of cardiology (15-02-2017)“…Abstract Long-term clinical outcomes of new-generation drug-eluting stents in complex anatomic and clinical settings are not well defined. This study assessed…”
Get full text
Journal Article -
13
Additive Value of Integrated Backscatter IVUS for Detection of Vulnerable Plaque by Optical Frequency Domain Imaging
Published in JACC. Cardiovascular imaging (01-02-2016)“…Abstract Objectives This study sought to evaluate the diagnostic performance of optical frequency domain imaging (OFDI) for recognition of coronary plaque…”
Get full text
Journal Article -
14
Impact of Coronary Calcium on Outcome Following Sirolimus-Eluting Stent Implantation
Published in The American journal of cardiology (15-08-2011)“…There remain a small but sizable number of patients who develop restenosis after sirolimus-eluting stent (SES) implantation. However, the cause of SES…”
Get full text
Journal Article -
15
The impact of renal impairment on long-term safety and effectiveness of drug-eluting stents
Published in PloS one (2014)“…Renal impairment (RI) is associated with impaired prognosis in patients with coronary artery disease. Clinical and angiographic outcomes of patients undergoing…”
Get full text
Journal Article -
16
Very Late Scaffold Thrombosis
Published in Journal of the American College of Cardiology (27-10-2015)“…Abstract Background Bioresorbable scaffolds provide transient lumen support followed by complete resorption. Objectives This study examined whether very late…”
Get full text
Journal Article -
17
-
18
Venous thoracic outlet syndrome, as a pitfall for cardiac implantable electronic device implantations
Published in Pacing and clinical electrophysiology (01-05-2024)“…The subclavian vein is typically used in cardiovascular implantable electronic device (CIED) implantations. External stress on the subclavian vein can lead to…”
Get full text
Journal Article -
19
Coronary stents: novel developments
Published in Heart (British Cardiac Society) (01-07-2014)Get more information
Journal Article -
20
Very Late Scaffold Thrombosis: Intracoronary Imaging and Histopathological and Spectroscopic Findings
Published in Journal of the American College of Cardiology (27-10-2015)“…Bioresorbable scaffolds provide transient lumen support followed by complete resorption. This study examined whether very late scaffold thrombosis (VLScT)…”
Get full text
Journal Article