Search Results - "Syms, R. R. A."

Refine Results
  1. 1

    Power waves and scattering parameters in magneto-inductive systems by Voronov, A., Sydoruk, O., Syms, R. R. A.

    Published in AIP advances (01-04-2021)
    “…Difficulties arise in the definition of power flow in transmission-line systems with a complex propagation constant. These were resolved by Kurokawa using…”
    Get full text
    Journal Article
  2. 2

    A Microelectromechanical Systems-Enabled, Miniature Triple Quadrupole Mass Spectrometer by Wright, Steven, Malcolm, Andrew, Wright, Christopher, O’Prey, Shane, Crichton, Edward, Dash, Neil, Moseley, Richard W, Zaczek, Wojciech, Edwards, Peter, Fussell, Richard J, Syms, Richard R. A

    Published in Analytical chemistry (Washington) (17-03-2015)
    “…Miniaturized mass spectrometers are becoming increasingly capable, enabling the development of many novel field and laboratory applications. However, to date,…”
    Get full text
    Journal Article
  3. 3

    Advances in microfabricated mass spectrometers by Syms, R. R. A

    Published in Analytical and bioanalytical chemistry (01-01-2009)
    “…Mass filters for miniature mass spectrometers are now being constructed using three-dimensional microfabrication techniques. Crossed-field, travelling-wave,…”
    Get full text
    Journal Article
  4. 4

    CDMA in Metamaterials Using Polyphase Codes by Syms, Richard R. A., Voronov, Artem

    Published in IEEE access (2024)
    “…Small code sets are required for asynchronous code division multiple access (CDMA) communication in dispersive channels such as metamaterials, for applications…”
    Get full text
    Journal Article
  5. 5

    MEMS-Based Nanospray-Ionization Mass Spectrometer by Wright, Steven, Syms, Richard R A, Moseley, Richard, Guodong Hong, O'Prey, Shane, Boxford, William E, Dash, Neil, Edwards, Peter

    Published in Journal of microelectromechanical systems (01-12-2010)
    “…An electrospray-ionization mass spectrometer (ESI-MS) whose main components are all fabricated using silicon microelectromechanical systems (MEMS) techniques…”
    Get full text
    Journal Article
  6. 6

    Intraductal magnetic resonance imaging of cholangiocarcinoma - a practical possibility by Syms, Richard R A, Wadsworth, Christopher A, Kardoulaki, Evdokia, Titapun, Attapol, Boonphongsathien, Wuttisak, Sa-Ngiamwibool, Prakasit, Zhang, Shuo, Taylor-Robinson, Simon D, Chamadol, Nittaya, Loilome, Watcharin

    Published in Frontiers in oncology (08-04-2024)
    “…Intraductal T2 mapping based on a catheter receiver is proposed as a method of visualizing the extent of intraductal and periductal cholangiocarcinoma (CCA)…”
    Get full text
    Journal Article
  7. 7

    Solvent-pumped evaporation concentration on paper in linear and radial geometries by Syms, Richard R. A., Wright, Steven

    Published in Biomicrofluidics (01-07-2023)
    “…Solvent-pumped evaporation-driven concentration of an initial distribution of solutes on a porous substrate is considered in one and two dimensions…”
    Get full text
    Journal Article
  8. 8

    Paper-based evaporation concentrators: Comparison of linear and radial geometries by Syms, Richard R. A., Wright, Steven

    Published in Biomicrofluidics (01-01-2023)
    “…Paper-based evaporation concentrators with linear and radial geometries are compared. A new method of finding approximate analytic solutions of the…”
    Get full text
    Journal Article
  9. 9

    In Vitro Intraductal MRI and T2 Mapping of Cholangiocarcinoma Using Catheter Coils by Khuntikeo, Narong, Titapun, Attapol, Chamadol, Nittaya, Boonphongsathien, Wuttisak, Sa-Ngiamwibool, Prakasit, Taylor-Robinson, Simon D, Wadsworth, Christopher A, Zhang, Shuo, Kardoulaki, Evdokia M, Syms, Richard R A

    Published in Hepatic medicine: evidence and research (01-01-2020)
    “…Diagnostic imaging of early-stage cholangiocarcinoma is challenging. A previous in vitro study of fixed-tissue liver resection specimens investigated T2…”
    Get full text
    Journal Article
  10. 10

    Parametric Amplification of Magnetic Resonance Images by Syms, R. R. A., Floume, T., Young, I. R., Solymar, L., Rea, M.

    Published in IEEE sensors journal (01-06-2012)
    “…Parametric amplification is considered as a method for the detection of magnetic resonance imaging (MRI) signals. The theory of three-frequency amplifiers is…”
    Get full text
    Journal Article
  11. 11

    Optical, thermal, and electrical monitoring of radio-frequency tissue modification by Floume, Timmy, Syms, Richard R. A, Darzi, Ara W, Hanna, George B

    Published in Journal of Biomedical Optics (01-01-2010)
    “…Radio-frequency (rf) tissue fusion involves the sealing of tissue between two electrodes delivering rf currents. Applications include small bowel fusion…”
    Get full text
    Journal Article
  12. 12

    Comparison of Ion Coupling Strategies for a Microengineered Quadrupole Mass Filter by Wright, Steven, Syms, Richard R.A., O'Prey, Shane, Hong, Guodong, Holmes, Andrew S.

    “…The limitations of conventional machining and assembly techniques require that designs for quadrupole mass analyzers with rod diameters less than a millimeter…”
    Get full text
    Journal Article
  13. 13

    Nanospray Dielectrophoresis by Tichem, M., Syms, R. R. A.

    Published in IEEE transactions on nanotechnology (01-11-2012)
    “…Self-assembly of nanoparticles into microscale patterns by spray deposition and dielectrophoresis is investigated using microfabricated RF traps and…”
    Get full text
    Journal Article
  14. 14

    A generic approach to boundary reflection in periodic media by SYMS, R. R. A, SOLYMAR, L

    “…Waves in periodic media, whose propagation is governed by nearest neighbour interaction, are investigated. The reflection and transmission coefficients are…”
    Get full text
    Journal Article
  15. 15

    Miniature Mass Spectrometer Systems Based on a Microengineered Quadrupole Filter by Malcolm, Andrew, Wright, Steven, Syms, Richard R. A, Dash, Neil, Schwab, Marc-André, Finlay, Alan

    Published in Analytical chemistry (Washington) (01-03-2010)
    “…Two miniature mass spectrometer systems based on a microengineered quadrupole mass filter have been developed. One of the instruments has a footprint of 27 cm…”
    Get full text
    Journal Article
  16. 16

    NEMS by Sidewall Transfer Lithography by Dixi Liu, Syms, Richard R. A.

    Published in Journal of microelectromechanical systems (01-12-2014)
    “…A batch fabrication process for nanoelectromechanical systems (NEMS) based on sidewall transfer lithography (STL) is demonstrated. The STL is used to form…”
    Get full text
    Journal Article
  17. 17

    Real-time optical monitoring of radio-frequency tissue fusion by continuous wave transmission spectroscopy by Floume, Timmy, Syms, Richard R A, Darzi, Ara W, Hanna, George B

    Published in Journal of biomedical optics (01-11-2008)
    “…Radio-frequency (RF) tissue fusion is a novel method of tissue approximation that can seal tissue without the need for sutures or staples, based on the…”
    Get more information
    Journal Article
  18. 18

    Transmission-Line Model of Noisy Electromagnetic Media by Syms, R. R. A., Sydoruk, O., Solymar, L.

    “…A transmission-line model of thermal noise in 1-D electromagnetic (EM) media is presented that can find both the magnetic and the electric contributions to the…”
    Get full text
    Journal Article
  19. 19

    Magnetic Resonance Imaging Duodenoscope by Syms, Richard R. A., Young, Ian R., Wadsworth, Christopher A., Taylor-Robinson, Simon D., Rea, Marc

    “…A side-viewing duodenoscope capable of both optical and magnetic resonance imaging (MRI) is described. The instrument is constructed from MR-compatible…”
    Get full text
    Journal Article
  20. 20

    Multilevel Self-Aligned Microcontact Printing System by Choonee, K, Syms, R. R. A

    Published in Langmuir (19-10-2010)
    “…A multilevel microcontact printing (μCP) system that avoids the use of optical alignment and precision manipulation equipment is demonstrated. Most of the…”
    Get full text
    Journal Article