Search Results - "Stoeber, B."
-
1
Arrays of hollow out-of-plane microneedles for drug delivery
Published in Journal of microelectromechanical systems (01-06-2005)“…Drug delivery based on MEMS technology requires an invasive interface such as microneedles, which connects the microsystem with the biological environment…”
Get full text
Journal Article -
2
Single Layer Deposition of Polystyrene Particles onto Planar Polydimethylsiloxane Substrates
Published in Langmuir (12-01-2016)“…This work investigates the deposition of polystyrene particles onto cross-linked polydimethylsiloxane (PDMS) substrates by using an impinging jet flow cell for…”
Get full text
Journal Article -
3
A micromechanical comparison of human and porcine skin before and after preservation by freezing for medical device development
Published in Scientific reports (25-08-2016)“…Collecting human skin samples for medical research, including developing microneedle-based medical devices, is challenging and time-consuming. Researchers rely…”
Get full text
Journal Article -
4
Concentration Field Evolution during the Drying of a Thin Polymer Solution Film near the Contact Line
Published in Langmuir (25-08-2015)“…An experimental study is performed for polymer concentration field measurements during the drying of an aqueous poly(vinyl alcohol) solution inside a shallow…”
Get full text
Journal Article -
5
Pneumatic balloon actuator control through integrated microvalves using thermally responsive fluids
Published in Sensors and actuators. A. Physical. (01-02-2019)“…In this work, we present the integration of a valve into the pressure supply channel for a pneumatic balloon actuator (PBA). We employed a microvalve using a…”
Get full text
Journal Article -
6
Effect of linear image processing on the depth of correlation in micro PIV
Published in Experiments in fluids (01-10-2014)“…This work investigates the effect of selected linear image processing methods on the depth of correlation (DoC) in micro particle image velocimetry using a…”
Get full text
Journal Article -
7
Flow control in microdevices using thermally responsive triblock copolymers
Published in Journal of microelectromechanical systems (01-04-2005)“…Active and passive microflow control has been demonstrated using gel formation by dilute aqueous solutions of triblock copolymers at elevated temperatures…”
Get full text
Journal Article -
8
Paper-based strain sensing material
Published in 2013 IEEE 26th International Conference on Micro Electro Mechanical Systems (MEMS) (01-01-2013)“…We have developed an inexpensive inkjet printing process to fabricate percolation-based resistive strain gauges in a paper substrate. These strain sensors were…”
Get full text
Conference Proceeding Journal Article -
9
On demand EWOD dropl let formation at a microfluidic T-junction
Published in 2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS) (01-06-2015)“…This paper illustrates a new method for creating air separated droplets on demand at a microfluidic T-junction in a microchannel using…”
Get full text
Conference Proceeding -
10
Germacranolide type sesquiterpene lactones from Neurolaena macrocephala
Published in Phytochemistry (Oxford) (01-04-1999)“…Two new neurolenin-type sesquiterpene lactones were found in the leaves of Neurolaena macrocephala Sch. Bip. Ex Hemsl. ( Asteraceae). These compounds were…”
Get full text
Journal Article -
11
Hollow Out-of-Plane Polymer Microneedles Made by Solvent Casting for Transdermal Drug Delivery
Published in Journal of microelectromechanical systems (01-02-2012)“…Although hollow microneedles have been proposed as an effective and convenient method for transdermal drug delivery, their expensive fabrication techniques to…”
Get full text
Journal Article -
12
Arrays of solvent cast hollow out-of-plane polymer microneedles for drug delivery
Published in 2011 IEEE 24th International Conference on Micro Electro Mechanical Systems (01-01-2011)“…Microneedles are tiny hollow structures that allow painless drug delivery into human skin. In this work, we present a novel fabrication method for…”
Get full text
Conference Proceeding -
13
Fluid injection through out-of-plane microneedles
Published in 1st Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.00EX451) (2000)“…In order to make frequent injections of insulin and other therapeutic agents more efficient, a new painless way to inject drug subcutaneously is investigated…”
Get full text
Conference Proceeding -
14
A microneedle-based glucose monitor: fabricated on a wafer-level using in-device enzyme immobilization
Published in TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664) (2003)“…This paper presents a disposable minimally invasive self-calibrating continuous glucose monitor consisting of hollow out-of-plane microneedles to sample…”
Get full text
Conference Proceeding -
15
Clinical microneedle injection of methyl nicotinate: stratum corneum penetration
Published in Skin research and technology (01-05-2005)“…In recent years, microneedles were proposed as a method to painlessly deliver drugs past the stratum corneum. Microneedles have been fabricated in several…”
Get more information
Journal Article -
16
Continuous Size-Separation of Airborne Particles in a Microchannel for Aerosol Monitoring
Published in IEEE sensors journal (01-11-2011)“…The real-time monitoring of aerosols is important for protecting human health and the environment. The small size of microchannels and their potential for…”
Get full text
Journal Article -
17
A planar 2-stage micromixer
Published in The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05 (2005)“…The paper describes a novel micromixing concept based on two independently actuated valves in a microfluidic system. Valve actuation results in periodic…”
Get full text
Conference Proceeding -
18
Implications of a low stiffness substrate in lamb wave gas sensing applications
Published in 2012 IEEE Sensors (01-10-2012)“…Numerical finite element analysis (FEA) of a poly(vinylidene fluoride) (PVDF) flexural plate wave (FPW) acoustic gravimetric gas sensor is used to study the…”
Get full text
Conference Proceeding -
19
Application of an all-polymer flexural plate wave sensor to polymer/solvent material characterization
Published in 2012 IEEE Sensors (01-10-2012)“…An all-polymer, polyvinylidene fluoride (PVDF) flexural plate wave (FPW) acoustic sensor is used to determine the humidity-dependent material parameters of a…”
Get full text
Conference Proceeding -
20
Advantages and special considerations in fabricating bubble circuits by electroplating and sputter etching
Published in IEEE transactions on magnetics (01-09-1974)“…A technology which has been used to fabricate a 1024 bit bubble domain memory with micron dimensions is described. The process uses additive electroplating…”
Get full text
Journal Article