Search Results - "Stoeber, B."

Refine Results
  1. 1

    Arrays of hollow out-of-plane microneedles for drug delivery by Stoeber, B., Liepmann, D.

    Published in Journal of microelectromechanical systems (01-06-2005)
    “…Drug delivery based on MEMS technology requires an invasive interface such as microneedles, which connects the microsystem with the biological environment…”
    Get full text
    Journal Article
  2. 2

    Single Layer Deposition of Polystyrene Particles onto Planar Polydimethylsiloxane Substrates by Mustin, B, Stoeber, B

    Published in Langmuir (12-01-2016)
    “…This work investigates the deposition of polystyrene particles onto cross-linked polydimethylsiloxane (PDMS) substrates by using an impinging jet flow cell for…”
    Get full text
    Journal Article
  3. 3

    A micromechanical comparison of human and porcine skin before and after preservation by freezing for medical device development by Ranamukhaarachchi, S. A., Lehnert, S., Ranamukhaarachchi, S. L., Sprenger, L., Schneider, T., Mansoor, I., Rai, K., Häfeli, U. O., Stoeber, B.

    Published in Scientific reports (25-08-2016)
    “…Collecting human skin samples for medical research, including developing microneedle-based medical devices, is challenging and time-consuming. Researchers rely…”
    Get full text
    Journal Article
  4. 4

    Concentration Field Evolution during the Drying of a Thin Polymer Solution Film near the Contact Line by Babaie, A, Stoeber, B

    Published in Langmuir (25-08-2015)
    “…An experimental study is performed for polymer concentration field measurements during the drying of an aqueous poly­(vinyl alcohol) solution inside a shallow…”
    Get full text
    Journal Article
  5. 5

    Pneumatic balloon actuator control through integrated microvalves using thermally responsive fluids by Konishi, S., Stoeber, B., Honda, S.

    Published in Sensors and actuators. A. Physical. (01-02-2019)
    “…In this work, we present the integration of a valve into the pressure supply channel for a pneumatic balloon actuator (PBA). We employed a microvalve using a…”
    Get full text
    Journal Article
  6. 6

    Effect of linear image processing on the depth of correlation in micro PIV by Mustin, B., Stoeber, B.

    Published in Experiments in fluids (01-10-2014)
    “…This work investigates the effect of selected linear image processing methods on the depth of correlation (DoC) in micro particle image velocimetry using a…”
    Get full text
    Journal Article
  7. 7

    Flow control in microdevices using thermally responsive triblock copolymers by Stoeber, B., Zhihao Yang, Liepmann, D., Muller, S.J.

    Published in Journal of microelectromechanical systems (01-04-2005)
    “…Active and passive microflow control has been demonstrated using gel formation by dilute aqueous solutions of triblock copolymers at elevated temperatures…”
    Get full text
    Journal Article
  8. 8

    Paper-based strain sensing material by Khajeh, E., Lou, W., Stoeber, B.

    “…We have developed an inexpensive inkjet printing process to fabricate percolation-based resistive strain gauges in a paper substrate. These strain sensors were…”
    Get full text
    Conference Proceeding Journal Article
  9. 9

    On demand EWOD dropl let formation at a microfluidic T-junction by He, K., Ahmadi, A., Walus, K., Stoeber, B.

    “…This paper illustrates a new method for creating air separated droplets on demand at a microfluidic T-junction in a microchannel using…”
    Get full text
    Conference Proceeding
  10. 10

    Germacranolide type sesquiterpene lactones from Neurolaena macrocephala by Passreiter, Claus M, Stoeber, Sebastian B, Ortega, Alfredo, Maldonado, Emma, Toscano, Ruben A

    Published in Phytochemistry (Oxford) (01-04-1999)
    “…Two new neurolenin-type sesquiterpene lactones were found in the leaves of Neurolaena macrocephala Sch. Bip. Ex Hemsl. ( Asteraceae). These compounds were…”
    Get full text
    Journal Article
  11. 11

    Hollow Out-of-Plane Polymer Microneedles Made by Solvent Casting for Transdermal Drug Delivery by Mansoor, I., Hafeli, U. O., Stoeber, B.

    Published in Journal of microelectromechanical systems (01-02-2012)
    “…Although hollow microneedles have been proposed as an effective and convenient method for transdermal drug delivery, their expensive fabrication techniques to…”
    Get full text
    Journal Article
  12. 12

    Arrays of solvent cast hollow out-of-plane polymer microneedles for drug delivery by Mansoor, I, Häfeli, U O, Stoeber, B

    “…Microneedles are tiny hollow structures that allow painless drug delivery into human skin. In this work, we present a novel fabrication method for…”
    Get full text
    Conference Proceeding
  13. 13

    Fluid injection through out-of-plane microneedles by Stoeber, B., Liepmann, D.

    “…In order to make frequent injections of insulin and other therapeutic agents more efficient, a new painless way to inject drug subcutaneously is investigated…”
    Get full text
    Conference Proceeding
  14. 14

    A microneedle-based glucose monitor: fabricated on a wafer-level using in-device enzyme immobilization by Zimmermann, S., Fienbork, D., Stoeber, B., Flounders, A.W., Liepmann, D.

    “…This paper presents a disposable minimally invasive self-calibrating continuous glucose monitor consisting of hollow out-of-plane microneedles to sample…”
    Get full text
    Conference Proceeding
  15. 15

    Clinical microneedle injection of methyl nicotinate: stratum corneum penetration by Sivamani, Raja K, Stoeber, Boris, Wu, Gabriel C, Zhai, Hongbo, Liepmann, Dorian, Maibach, Howard

    Published in Skin research and technology (01-05-2005)
    “…In recent years, microneedles were proposed as a method to painlessly deliver drugs past the stratum corneum. Microneedles have been fabricated in several…”
    Get more information
    Journal Article
  16. 16

    Continuous Size-Separation of Airborne Particles in a Microchannel for Aerosol Monitoring by Schaap, A. M., Chu, W. C., Stoeber, B.

    Published in IEEE sensors journal (01-11-2011)
    “…The real-time monitoring of aerosols is important for protecting human health and the environment. The small size of microchannels and their potential for…”
    Get full text
    Journal Article
  17. 17

    A planar 2-stage micromixer by Stoeber, B., Liepmann, D., Muller, S.J.

    “…The paper describes a novel micromixing concept based on two independently actuated valves in a microfluidic system. Valve actuation results in periodic…”
    Get full text
    Conference Proceeding
  18. 18

    Implications of a low stiffness substrate in lamb wave gas sensing applications by Sielmann, C., Stoeber, B., Walus, K.

    Published in 2012 IEEE Sensors (01-10-2012)
    “…Numerical finite element analysis (FEA) of a poly(vinylidene fluoride) (PVDF) flexural plate wave (FPW) acoustic gravimetric gas sensor is used to study the…”
    Get full text
    Conference Proceeding
  19. 19

    Application of an all-polymer flexural plate wave sensor to polymer/solvent material characterization by Sielmann, C., Berring, J., Walus, K., Stoeber, B.

    Published in 2012 IEEE Sensors (01-10-2012)
    “…An all-polymer, polyvinylidene fluoride (PVDF) flexural plate wave (FPW) acoustic sensor is used to determine the humidity-dependent material parameters of a…”
    Get full text
    Conference Proceeding
  20. 20

    Advantages and special considerations in fabricating bubble circuits by electroplating and sputter etching by Romankiw, L., Krongelb, S., Castellani, E., Pfeiffer, A., Stoeber, B., Olsen, J.

    Published in IEEE transactions on magnetics (01-09-1974)
    “…A technology which has been used to fabricate a 1024 bit bubble domain memory with micron dimensions is described. The process uses additive electroplating…”
    Get full text
    Journal Article