Search Results - "Stoddard, Marcus F."
-
1
Cardiac stem cells in patients with ischaemic cardiomyopathy (SCIPIO): initial results of a randomised phase 1 trial
Published in The Lancet (British edition) (26-11-2011)“…Summary Background c-kit-positive, lineage-negative cardiac stem cells (CSCs) improve post-infarction left ventricular (LV) dysfunction when administered to…”
Get full text
Journal Article -
2
Systolic and diastolic function in chronic spinal cord injury
Published in PloS one (27-07-2020)“…Individuals with spinal cord injury develop cardiovascular disease more than age-matched, non-injured cohorts. However, progression of systolic and diastolic…”
Get full text
Journal Article -
3
Frequent premature atrial contractions impair left atrial contractile function and promote adverse left atrial remodeling
Published in Echocardiography (Mount Kisco, N.Y.) (01-09-2018)“…Objectives This study assessed if frequent premature atrial contractions (PACs) were associated with decreased left atrial (LA) strain and adverse remodeling…”
Get full text
Journal Article -
4
Beneficial Cardiac Structural and Functional Adaptations After Lumbosacral Spinal Cord Epidural Stimulation and Task-Specific Interventions: A Pilot Study
Published in Frontiers in neuroscience (22-10-2020)“…Cardiac myocyte atrophy and resulting decreases to left ventricular mass and dimensions are well-documented in spinal cord injury. Therapeutic interventions…”
Get full text
Journal Article -
5
4D UTE flow: A phase-contrast MRI technique for assessment and visualization of stenotic flows
Published in Magnetic resonance in medicine (01-03-2015)“…Purpose Inaccuracy of conventional four‐dimensional (4D) flow MR imaging in the presence of random unsteady and turbulent blood flow distal to a narrowing has…”
Get full text
Journal Article -
6
Intrapulmonary Shunt Is a Potentially Unrecognized Cause of Ischemic Stroke and Transient Ischemic Attack
Published in Journal of the American Society of Echocardiography (01-07-2013)“…Background Ischemic stroke is a major cause of mortality and disability. Transient ischemic attack (TIA) is a harbinger of stroke. The etiology of stroke in as…”
Get full text
Journal Article -
7
Delayed preconditioning-mimetic action of nitroglycerin in patients undergoing coronary angioplasty
Published in Circulation (New York, N.Y.) (19-06-2001)“…Experimental studies suggest that the cardioprotective effects of the late phase of ischemic preconditioning (PC) can be mimicked pharmacologically. However,…”
Get full text
Journal Article -
8
4Dflow‐VP‐Net: A deep convolutional neural network for noninvasive estimation of relative pressures in stenotic flows from 4D flow MRI
Published in Magnetic resonance in medicine (01-11-2023)“…Purpose To estimate relative transvalvular pressure gradient (TVPG) noninvasively from 4D flow MRI. Methods A novel deep learning–based approach is proposed to…”
Get full text
Journal Article -
9
Administration of Cardiac Stem Cells in Patients With Ischemic Cardiomyopathy: The SCIPIO Trial Surgical Aspects and Interim Analysis of Myocardial Function and Viability by Magnetic Resonance
Published in Circulation (New York, N.Y.) (11-09-2012)“…SCIPIO is a first-in-human, phase 1, randomized, open-label trial of autologous c-kit(+) cardiac stem cells (CSCs) in patients with heart failure of ischemic…”
Get full text
Conference Proceeding Journal Article -
10
Comprehensive Left Atrial Appendage Optimization of Thrombus Using Surface Echocardiography: The CLOTS Multicenter Pilot Trial
Published in Journal of the American Society of Echocardiography (01-10-2009)“…Background The aim of this study was to determine the ability to identify thrombus within the left atrial appendage (LAA) in the setting of atrial fibrillation…”
Get full text
Journal Article -
11
Echo Training Post-COVID: Response from the National Board of Echocardiography
Published in Journal of the American Society of Echocardiography (01-08-2020)Get full text
Journal Article -
12
Dual‐Venc acquisition for 4D flow MRI in aortic stenosis with spiral readouts
Published in Journal of magnetic resonance imaging (01-07-2020)“…Background Single Venc 4D flow MRI with Cartesian readout is hampered by poor velocity resolution and noise when imaging during diastole. Dual Venc…”
Get full text
Journal Article -
13
Comparison of Anticoagulant and Anti-Inflammatory Responses Using Enoxaparin Versus Unfractionated Heparin for Transesophageal Echocardiography-Guided Cardioversion of Atrial Fibrillation
Published in The American journal of cardiology (01-10-2008)“…The Assessment of Cardioversion Using Transesophageal Echocardiography (ACUTE) II study compared enoxaparin with unfractionated heparin (UFH) as bridging…”
Get full text
Journal Article -
14
Bradykinin-induced preconditioning in patients undergoing coronary angioplasty
Published in Journal of the American College of Cardiology (01-09-1999)“…OBJECTIVES The purpose of this study was to determine whether administration of bradykinin reproduces the cardioprotective effects of ischemic preconditioning…”
Get full text
Journal Article -
15
The evolution of apical hypertrophic cardiomyopathy: Development of mid‐ventricular obstruction and apical aneurysm 11 years after initial diagnosis
Published in Echocardiography (Mount Kisco, N.Y.) (01-05-2019)“…Asian hypertrophic cardiomyopathy (AHCM) is a rare variant of hypertrophic cardiomyopathy (HCM) that is more prevalent in the Asian population. There is…”
Get full text
Journal Article -
16
4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis
Published in Magnetic resonance in medicine (01-03-2016)“…Purpose The utility of four‐dimensional (4D) spiral flow in imaging of stenotic flows in both phantoms and human subjects with aortic stenosis is investigated…”
Get full text
Journal Article -
17
Acquired aortic cusp fusion after chronic left ventricular assist device support
Published in Journal of the American Society of Echocardiography (01-11-2006)“…Explanted hearts from patients with chronic left ventricular assist device (LVAD) support have shown the presence of aortic cusp fusion, which results in…”
Get more information
Journal Article -
18
Two‐dimensional strain echocardiography‐derived left ventricular ejection fraction, volumes, and global systolic dyssynchrony index: Comparison with three‐dimensional echocardiography
Published in Echocardiography (Mount Kisco, N.Y.) (01-06-2019)“…Background Three‐dimensional (3D) echocardiography is the most accurate echocardiographic method for ventricular chamber quantification. It is unclear how…”
Get full text
Journal Article -
19
Dual-V enc acquisition for 4D flow MRI in aortic stenosis with spiral readouts
Published in Journal of magnetic resonance imaging (01-07-2020)“…Single V 4D flow MRI with Cartesian readout is hampered by poor velocity resolution and noise when imaging during diastole. Dual V acquisitions typically…”
Get full text
Journal Article -
20
Childhood cancer survivors: The integral role of the cardiologist and cardiovascular imaging
Published in The American heart journal (01-08-2020)“…With 80% of childhood cancer survivors (CCS) alive 30 years after diagnosis, preventable causes of death, such as cardiovascular disease resulting from initial…”
Get full text
Journal Article