Search Results - "Spanoudaki, V."
-
1
Investigating the temporal resolution limits of scintillation detection from pixellated elements: comparison between experiment and simulation
Published in Physics in medicine & biology (07-02-2011)“…This study investigates the physical limitations involved in the extraction of accurate timing information from pixellated scintillation detectors for positron…”
Get more information
Journal Article -
2
Physical effects of mechanical design parameters on photon sensitivity and spatial resolution performance of a breast-dedicated PET system
Published in Medical physics (Lancaster) (01-11-2010)“…Purpose: This study aims to address design considerations of a high resolution, high sensitivity positron emission tomography scanner dedicated to breast…”
Get full text
Journal Article -
3
Effect of inter-crystal scatter on estimation methods for random coincidences and subsequent correction
Published in Physics in medicine & biology (07-05-2008)“…Random coincidences can contribute substantially to the background in positron emission tomography (PET). Several estimation methods are being used for…”
Get more information
Journal Article -
4
Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging
Published in Physics in medicine & biology (21-01-2004)“…Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms…”
Get more information
Journal Article -
5
A true singles list-mode data acquisition system for a small animal PET scanner with independent crystal readout
Published in Physics in medicine & biology (21-07-2005)“…We present a unique data acquisition system designed to read out signals from the MADPET-II small animal LSO-APD PET tomograph. The scanner consists of 36…”
Get more information
Journal Article -
6
Use of a Central Positron Emitting Reference Source to Improve the Timing Alignment of a Singles List-Mode Small Animal PET Scanner
Published in IEEE transactions on nuclear science (01-02-2007)“…To minimize the system-wide timing resolution of a PET scanner, and hence the applied coincidence window, a delay must be added to the signals from each…”
Get full text
Journal Article -
7
Tomographic image reconstruction using Artificial Neural Networks
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-07-2004)“…A new image reconstruction technique based on the usage of an Artificial Neural Network (ANN) is presented. The most crucial factor in designing such a…”
Get full text
Journal Article -
8
Design and development of a position-sensitive γ-camera for SPECT imaging based on PCI electronics
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-07-2004)“…A position-sensitive γ-camera is being currently designed at IASA. This camera will be used experimentally (development mode) in order to obtain an integrated…”
Get full text
Journal Article -
9
Crystal and collimator optimization studies of a high-resolution γ-camera based on a position sensitive photomultiplier
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-07-2004)“…Studies have been performed in order to optimize the collimator and the crystal of a γ-camera based on a position sensitive photomultiplier with respect its…”
Get full text
Journal Article -
10
High-resolution and high-sensitivity SPECT imaging of breast phantoms
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-07-2004)“…A small field of view gamma camera based on a Position Sensitive Photomultiplier Tube has been used for tomoscintigraphic imaging of breast phantoms. The…”
Get full text
Journal Article -
11
First Performance Results of Ce:GAGG Scintillation Crystals With Silicon Photomultipliers
Published in IEEE transactions on nuclear science (01-04-2013)“…A new single-crystal Cerium doped Gd 3 Al 2 Ga 3 O 123 Al 2 Ga 3 O 12 (GAGG) scintillation crystal with high luminosity, high density and relatively fast decay…”
Get full text
Journal Article -
12
Physical effects of mechanical design parameters on photonsensitivity and spatial resolution performance of a breast-dedicatedPET system
Published in Medical physics (Lancaster) (19-10-2010)“…Purpose: This study aims to address design considerations of a high resolution, high sensitivity positron emission tomography scanner dedicated to breast…”
Get full text
Journal Article -
13
Estimating accidental coincidences for pixelated PET detectors and singles list-mode acquisition
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2007)“…We have studied the validity of random estimation techniques for various low energy thresholds (LETs) and single list-mode data sets in small animal PET. While…”
Get full text
Journal Article -
14
Silicon photomultiplier-based detector array for TOF PET
Published in 2011 IEEE Nuclear Science Symposium Conference Record (01-10-2011)“…Time-of-Flight (ToF) information in PET can contribute to a significant improvement in the reconstructed image signal to noise ratio, enabling image contrast…”
Get full text
Conference Proceeding -
15
Effect of Temperature on the Performance of Proportional APD-Based Modules for Gamma Ray Detection in Positron Emission Tomography
Published in IEEE transactions on nuclear science (01-02-2008)“…MADPET-II is a small animal PET tomograph that features individual lutetium oxyorthosilicate (LSO) crystal readout from avalanche photodiodes (APDs). The…”
Get full text
Journal Article -
16
Comparison of CsI(Tl) and CsI(Na) partially slotted crystals for high-resolution SPECT imaging
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (20-12-2006)“…Dedicated systems based on Position Sensitive Photomultiplier Tubes (PSPMTs) coupled to scintillators, have been used over the past years for the construction…”
Get full text
Journal Article -
17
An analog signal processing ASIC for a small animal LSO–APD PET tomograph
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-08-2006)“…MADPET-II is a small animal PET scanner currently under development that provides individual readout for each one of its 1152 LSO–APD electronic channels. In…”
Get full text
Journal Article -
18
Partially slotted crystals for a high-resolution γ-camera based on a position sensitive photomultiplier
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-09-2005)“…Partially slotted crystals have been designed and constructed and have been used to evaluate the performance with respect to the spatial resolution of a…”
Get full text
Journal Article -
19
Temperature and bias voltage studies of a large area position sensitive Avalanche Photodiode
Published in 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) (01-10-2009)“…We are constructing a 1 mm 3 resolution, high sensitivity PET detector system with depth of interaction capability. The detectors are built from modules…”
Get full text
Conference Proceeding -
20
Effect of temperature on the stability and performance of an LSO-APD PET scanner
Published in IEEE Nuclear Science Symposium Conference Record, 2005 (2005)“…PET scanners with a large number of individual detectors require an equivalent number of electronics that will collect the detector signals and further process…”
Get full text
Conference Proceeding