An assessment of errors in sample preparation and data processing for nanoparticle size analyses by AFM

Accurate measurements of particle size, which are essential for a better understanding of nanoparticle properties, are often influenced by sample preparation and image data treatment. In this work, we discuss the errors associated with different methods of sample preparation and data treatment in AF...

Full description

Saved in:
Bibliographic Details
Published in:Materials characterization Vol. 109; pp. 198 - 205
Main Authors: Souza, T.G.F., Ciminelli, V.S.T., Mohallem, N.D.S.
Format: Journal Article
Language:English
Published: Elsevier Inc 01-11-2015
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Accurate measurements of particle size, which are essential for a better understanding of nanoparticle properties, are often influenced by sample preparation and image data treatment. In this work, we discuss the errors associated with different methods of sample preparation and data treatment in AFM size measurements using polystyrene nanoparticles with sizes of 102±3nm on silicon and mica substrates. Silicon has the advantage over mica of being conductive. The dilution of the polymeric nanoparticle suspension was sufficient to achieve good dispersion on the mica substrate, but not on silicon. Sample preparation on silicon was significantly improved by treating the substrate with glow discharge. The addition of a dispersant can cause errors of approximately 20% if the height of the coating that is formed is not considered in the particle size measurement. Both the software for data treatment and the type of flattening procedure were shown to influence the particle size measurement. Particle size has been significantly influenced by data treatment and the type of flattening procedure. No meaningful effect of the interpolation method on the measurements of the average particle size was observed under the experimental conditions, but the variance was affected. The results also demonstrated that image size and pixel size should be carefully selected to obtain an accurate measurement in a short period of time. The results were compared using Student's t-test at a 99% confidence level. Accurate measurements of particle size are often influenced by sample preparation and image data treatment. The errors associated with different methods of sample preparation and data treatment in AFM size measurements of polystyrene nanoparticles are evaluated. [Display omitted]
ISSN:1044-5803
1873-4189
DOI:10.1016/j.matchar.2015.09.020