Search Results - "Siddons, D.P"

Refine Results
  1. 1

    Performance of a Thin-Window Silicon Drift Detector X-Ray Fluorescence Spectrometer by Carini, G.A., Wei Chen, De Geronimo, G., Gaskin, J.A., Keister, J.W., Zheng Li, Ramsey, B.D., Rehak, P., Siddons, D.P.

    Published in IEEE transactions on nuclear science (01-10-2009)
    “…Several sets of hexagonal Silicon Drift Detector (SDD) arrays were produced by Brookhaven National Laboratory (BNL) and by the commercial vendor, KETEK. These…”
    Get full text
    Journal Article
  2. 2
  3. 3

    Development of a high-rate high-resolution detector for EXAFS experiments by De Geronimo, G., O'Connor, P., Beuttenmuller, R.H., Li, Z., Kuczewski, A.J., Siddons, D.P.

    Published in IEEE transactions on nuclear science (01-08-2003)
    “…A new detector for EXAFS experiments is being developed. It is based on a multi-element Si sensor and dedicated readout application specific integrated circuit…”
    Get full text
    Journal Article
  4. 4

    Synchrotron radiation response characterization of coplanar grid CZT detectors by Carini, G.A., Bolotnikov, A.E., Camarda, G.S., Wright, G.W., De Geronimo, G., Siddons, D.P., James, R.B.

    Published in IEEE transactions on nuclear science (01-10-2005)
    “…Commercial 15/spl times/15/spl times/7.5 mm/sup 3/ coplanar grid CdZnTe detectors were studied on the micron-scale using a collimated high-energy X-ray beam…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Design, simulation and testing of large area silicon drift detectors and detector array for X-ray spectroscopy by Zhang, W.C., Li, Z., Siddons, D.P., Huang, W., Zhao, L.J., Kakuno, E.M., Pietraski, P., Li, C.J.

    Published in IEEE transactions on nuclear science (01-08-2000)
    “…Large area (25 mm/sup 2/) silicon drift detectors and detector arrays (5/spl times/5) have been designed, simulated, and fabricated for X-ray spectroscopy. On…”
    Get full text
    Journal Article
  7. 7
  8. 8

    Mössbauer spectroscopy using synchrotron radiation: overcoming detector limitations by Siddons, D.P., Hastings, J.B., Bergmann, U., Sette, F., Krisch, M.

    “…Mössbauer spectroscopy using synchrotron radiation has previously been limited by the presence of a large non-resonant radiation background which dominates the…”
    Get full text
    Journal Article
  9. 9
  10. 10

    Insights into molecular chemistry of Chiapas amber using infrared-light microscopy, PIXE/RBS, and sulfur K-edge XANES spectroscopy by Riquelme, Francisco, Northrup, Paul, Ruvalcaba-Sil, José Luis, Stojanoff, Vivian, Peter Siddons, D., Alvarado-Ortega, Jesús

    “…Chiapas amber is a natural occurring fossil resin structurally composed of long macromolecule chains with semicrystalline phases associated with both fossil…”
    Get full text
    Journal Article
  11. 11

    Band alignment of atomic layer deposited HfO2 on clean and N passivated germanium surfaces by Rumaiz, Abdul K., Woicik, J. C., Carini, G. A., Siddons, D. P., Cockayne, E., Huey, E., Lysaght, P. S., Fischer, D. A., Genova, V.

    Published in Applied physics letters (13-12-2010)
    “…Hard x-ray photoelectron spectroscopy has been used to study the band alignment between atomic layer deposited HfO2 on clean Ge (100) and nitrogen treated Ge…”
    Get full text
    Journal Article
  12. 12

    Band alignment in Ge/GeOx/HfO2/TiO2 heterojunctions as measured by hard x-ray photoelectron spectroscopy by Rumaiz, A. K., Woicik, J. C., Weiland, C., Xie, Q., Siddons, D. P., Jaffari, G. H., Detavernier, C.

    Published in Applied physics letters (26-11-2012)
    “…We investigate the interlayer (IL) thickness dependence of band offsets in a germanium based bilayer metal-oxide-semiconductor sandwich with an amorphous…”
    Get full text
    Journal Article
  13. 13

    Charge-pump detector for X-ray correlation spectroscopy by Carini, Gabriella A., Rehak, Pavel, Chen, Wei, Peter Siddons, D.

    “…A detector for the X-ray Correlation Spectroscopy (XCS) instrument at the Linac Coherent Light Source (LCLS) in Stanford (CA) is being developed at Brookhaven…”
    Get full text
    Journal Article
  14. 14
  15. 15
  16. 16

    Hard real-time quick EXAFS data acquisition with all open source software on a commodity personal computer by So, I., Siddons, D.P., Caliebe, W.A., Khalid, S.

    “…We describe here the data acquisition subsystem of the Quick EXAFS (QEXAFS) experiment at the National Synchrotron Light Source of Brookhaven National…”
    Get full text
    Journal Article
  17. 17

    ASIC for SDD-Based X-Ray Spectrometers by De Geronimo, Gianluigi, Rehak, Pavel, Ackley, Kim, Carini, Gabriella, Wei Chen, Fried, Jack, Keister, Jeffrey, Shaorui Li, Zheng Li, Pinelli, Donald A, Siddons, D Peter, Vernon, Emerson, Gaskin, Jessica A, Ramsey, Brian D, Tyson, Trevor A

    Published in IEEE transactions on nuclear science (01-06-2010)
    “…We present an application-specific integrated circuit (ASIC) for high-resolution x-ray spectrometers (XRS). The ASIC reads out signals from pixelated silicon…”
    Get full text
    Journal Article
  18. 18

    Large detector array and real-time processing and elemental image projection of X-ray and proton microprobe fluorescence data by Ryan, C.G., Siddons, D.P., Moorhead, G., Kirkham, R., Dunn, P.A., Dragone, A., De Geronimo, G.

    “…A detector concept is described that integrates a large solid-angle detector array developed at Brookhaven National Laboratory and a high speed pipelined…”
    Get full text
    Journal Article
  19. 19

    Gas electron multiplier (GEM) enhanced ionization chamber for fluorescence detector by Shaban, E.H., Siddons, D.P., Kuczewski, A.

    “…Detecting dilute elements in thin materials using extended X-ray absorption fluorescence spectroscopy (EXAFS) method requires a detector capable of high count…”
    Get full text
    Journal Article
  20. 20

    Elimination of the inner-shell lifetime broadening in X-ray-absorption spectroscopy by HAMALAINEN, K, SIDDONS, D. P, HASTINGS, J. B, BERMAN, L. E

    Published in Physical review letters (11-11-1991)
    “…A novel method to measure x-ray-absorption spectra without the inner-shell lifetime broadening is presented. It is based on a high-resolution spectrometer…”
    Get full text