Search Results - "Shu, Lichun"

Refine Results
  1. 1

    Comparison of DC Pollution Flashover Performances of Various Types of Porcelain, Glass, and Composite Insulators by Xingliang Jiang, Xingliang Jiang, Jihe Yuan, Jihe Yuan, Lichun Shu, Lichun Shu, Zhijin Zhang, Zhijin Zhang, Jianlin Hu, Jianlin Hu, Feng Mao, Feng Mao

    Published in IEEE transactions on power delivery (01-04-2008)
    “…Based on the artificial pollution tests, the flashover performance of various types of DC porcelain and glass suspension insulators as well as composite…”
    Get full text
    Journal Article
  2. 2

    Mechanism of self-recovery of hydrophobicity after surface damage of lotus leaf by Wang, Li, Shu, Lichun, Hu, Qin, Jiang, Xingliang, Yang, Hang, Wang, Huan, Rao, Lipeng

    Published in Plant methods (21-03-2024)
    “…The surfaces of lotus leaves with micro- and nano-waxy cuticle structures are superhydrophobic and possess a self-healing ability to regain hydrophobicity…”
    Get full text
    Journal Article
  3. 3

    Flashover Voltage Prediction of Composite Insulators Based on the Characteristics of Leakage Current by Shihua Zhao, Xingliang Jiang, Zhijing Zhang, Jianlin Hu, Lichun Shu

    Published in IEEE transactions on power delivery (01-07-2013)
    “…Effective prediction of flashover voltage (FOV) of insulators is an important approach to the prevention of pollution flashover accidents. In order to predict…”
    Get full text
    Journal Article
  4. 4

    Predictive Model for Equivalent Ice Thickness Load on Overhead Transmission Lines Based on Measured Insulator String Deviations by Jiang, Xingliang, Xiang, Ze, Zhang, Zhijin, Hu, Jianlin, Hu, Qin, Shu, Lichun

    Published in IEEE transactions on power delivery (01-08-2014)
    “…Transmission-line icing presents a serious threat to the safe operation of power systems. Therefore, the icing condition of overhead transmission lines must be…”
    Get full text
    Journal Article
  5. 5

    Numerical and Experimental Investigations of Deicing Performance for the Pneumatic Impulse Deicing Method by Shu, Lichun, Yu, Zhou, Hu, Qin, Jiang, Xingliang

    Published in Journal of marine science and engineering (01-07-2023)
    “…Wind turbines operating in cold regions are more likely to sustain extreme icing, causing the degradation of aerodynamic performance and the loss of wind…”
    Get full text
    Journal Article
  6. 6

    Effects of artificial polluting methods on AC flashover voltage of composite insulators by Dong, Bingbing, Jiang, Xingliang, Hu, Jianlin, Shu, Lichun, Sun, Caixin

    “…In artificial pollution tests, there are three polluting methods frequently used, including quantitative Brushing Method (BM), Dipping Method (DM) and Spraying…”
    Get full text
    Journal Article
  7. 7

    Effects of electric field distribution on icing and flashover performance of 220 kV composite insulators by Hu, Qin, Yuan, Wei, Shu, Lichun, Jiang, Xingliang, Wang, Shijing

    “…The energized icing of composite insulators has been studied by the researchers around the world, but not much about the effects of electric field distribution…”
    Get full text
    Journal Article
  8. 8

    Comparison of AC icing flashover performances of 220 kV composite insulators with different shed configurations by Hu, Qin, Wang, Shijing, Shu, Lichun, Jiang, Xingliang, Liang, Jian, Qiu, Gang

    “…The shed configuration has obvious effects on the flow field characteristics and electric field distributions around composite insulators, and then impacts…”
    Get full text
    Journal Article
  9. 9

    Simulation and Experimental Investigation of DC Ice-Melting Process on an Iced Conductor by Jiang, Xingliang, Fan, Songhai, Zhang, Zhijin, Sun, Caixin, Shu, Lichun

    Published in IEEE transactions on power delivery (01-04-2010)
    “…Ice melting with dc is one of the key technologies to prevent the Chinese power grid from ice storms. Especially after the severe ice storm in the southern…”
    Get full text
    Journal Article
  10. 10

    DC flashover performance and effect of sheds configuration on polluted and ice-covered composite insulators at low atmospheric pressure by Jiang, Xingliang, Chao, Yafeng, Zhang, Zhijin, Hu, Jianlin, Shu, Lichun

    “…How to choose external insulation under high altitude, pollution and icing conditions for UHVDC transmission project is a complicated problem. To provide…”
    Get full text
    Journal Article
  11. 11

    Influence of shed configuration on icing characteristics and flashover performance of 220 kV composite insulators by Hu, Qin, Wang, Shijing, Shu, Lichun, Jiang, Xingliang, Qiu, Gang, Li, Hantao

    “…Shed configuration is one of the important factors affecting the icing characteristics and icing flashover performance of composite insulators. In this paper,…”
    Get full text
    Journal Article
  12. 12

    Simulation Study on the Effects of DC Electric Field on Insulator Surface Pollution Deposit by Zhang, Dongdong, Zhang, Zhijin, Jiang, Xingliang, Shu, Lichun, Wu, Bin

    Published in Energies (Basel) (01-03-2018)
    “…Energized insulator’s surface contamination is greatly affected by its electric field properties. However, few reports about the electric field influencing…”
    Get full text
    Journal Article
  13. 13

    Three-dimensional electric field simulation and flashover path analysis of ice-covered suspension insulators by Shu, Lichun, Liu, Yanqing, Jiang, Xingliang, Hu, Qin, He, Gaohui, Yu, Zhou, Xiao, Longfang

    Published in High voltage (01-06-2020)
    “…Flashover of ice-covered insulators seriously affects the safe operation of transmission lines. It is necessary to study the electric field distribution for…”
    Get full text
    Journal Article
  14. 14

    Flashover Performance of Pre-contaminated and Ice-covered Composite Insulators to be Used in 1000 kV UHV AC Transmission Lines by Hu, Jianlin, Sun, Caixin, Jiang, Xingliang, Zhang, Zhijin, Shu, Lichun

    “…A method is introduced for testing insulators under icing conditions. The method is based on and developed from those described in the standard of IEC60-1, IEC…”
    Get full text
    Journal Article
  15. 15

    The freezing process of continuously sprayed water droplets on the superhydrophobic silicone acrylate resin coating surface by Hu, Jianlin, Xu, Ke, Wu, Yao, Lan, Binhuan, Jiang, Xingliang, Shu, Lichun

    Published in Applied surface science (30-10-2014)
    “…•Superhydrophobic and hydrophobic silicone acrylate resin coatings were prepared.•Freezing mechanism of continuously sprayed droplets was pointed…”
    Get full text
    Journal Article
  16. 16

    Impact of icing severity on corona performance of glaze ice-covered conductor by He, Gaohui, Hu, Qin, Shu, Lichun, Jiang, Xingliang, Liu, Yanqing, Wu, Weiwei, Li, Yongfu, Peng, Huadong

    “…This paper presents the results of laboratory experiments carried out on an ac-energized stranded conductor subjected to simulated glaze icing, which were…”
    Get full text
    Journal Article
  17. 17

    Study of DC flashover performance of ice-covered insulators at high altitude by Jiang, Xingliang, Zhao, Shihua, Hu, Jianlin, Zhang, Zhijin, Shu, Lichun

    “…This paper examines the direct current (DC) icing flashover performance of typical DC porcelain, glass, and composite insulators in a complex environment of…”
    Get full text
    Journal Article
  18. 18

    Modeling of AC flashover on ice-covered composite insulators with different shed configurations by Shu, Lichun, Wang, Shijing, Jiang, Xingliang, Hu, Qin, Liang, Jian, Yin, Pancheng, Chen, Ji

    “…The shed configuration has an obvious effect on flashover performance of ice-covered composite insulators. Based on the flashover arc path, a "multi-arc,…”
    Get full text
    Journal Article
  19. 19

    Effect of shed configuration on DC flashover performance of ice-covered 110 kV composite insulators by Jiang, Xingliang, Dong, Bingbing, Zhang, Zhijin, Yin, Fanghui, Shu, Lichun

    “…Composite insulators have been used in power system for more than 20 years in China. Compared to porcelain and glass insulators, the pollution flashover…”
    Get full text
    Journal Article
  20. 20

    Effects of shed configuration on AC flashover performance of ice-covered composite long-rod insulators by Hu, Qin, Shu, Lichun, Jiang, Xingliang, Sun, Caixin, Zhang, Zhijin, Hu, Jianlin

    “…The flashover tests of artificially ice-covered composite long-rod insulators, including four types with a nominal voltage of 110 kV, four types of 220 kV and…”
    Get full text
    Journal Article