Search Results - "Sheppard, N. F."
-
1
Enzyme microgels in packed-bed bioreactors with downstream amperometric detection using microfabricated interdigitated microsensor electrode arrays
Published in Biotechnology and bioengineering (20-11-2001)“…In this article, we describe the use of pH‐ responsive hydrogels as matrices for the immobilization of two enzymes, glucose oxidase (GOx) and glutamate oxidase…”
Get full text
Journal Article -
2
Magnitude and modulation of pancreatic beta-cell gap junction electrical conductance in situ
Published in The Journal of membrane biology (01-07-1995)“…The parallel gap junction electrical conductance between a beta-cell and its nearest neighbors was measured by using an intracellular microelectrode to clamp…”
Get full text
Journal Article -
3
Evidence that calcium release-activated current mediates the biphasic electrical activity of mouse pancreatic beta-cells
Published in The Journal of membrane biology (01-01-1997)“…The electrical response of pancreatic beta-cells to step increases in glucose concentration is biphasic, consisting of a prolonged depolarization with action…”
Get full text
Journal Article -
4
Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Published in Analytical chemistry (Washington) (15-10-1999)“…This paper describes a microfluidic system in which fluids are pumped by centrifugal force through microscopic channels defined in a plastic disk in order to…”
Get full text
Journal Article -
5
Functional Organization of Rat Olfactory Bulb Glomeruli Revealed by Optical Imaging
Published in The Journal of neuroscience (01-04-1998)“…The functional organization and synaptic physiology of olfactory bulb glomeruli were studied in rat in vitro slice preparations stained with the…”
Get full text
Journal Article -
6
Mapping Membrane Potential Transients in Crayfish (Procambarus clarkii) Optic Lobe Neuropils With Voltage-Sensitive Dyes
Published in Journal of neurophysiology (01-01-1999)“…Sergey Yagodin 1 , 3 , Carlos Collin 2 , Daniel L. Alkon 2 , Norman F. Sheppard Jr. 1 , and David B. Sattelle 3 1 Department of Biomedical Engineering, Johns…”
Get full text
Journal Article -
7
Electrical conductivity of pH-responsive hydrogels
Published in Journal of biomaterials science. Polymer ed. (01-01-1997)“…The electrical conductivity of pH-responsive hydrogels based on cross-linked poly(2-hydroxyethyl methacrylate-co-dimethylaminoethyl methacrylate) copolymers…”
Get full text
Journal Article -
8
Model of an immobilized enzyme conductimetric urea biosensor
Published in Biosensors & bioelectronics (1996)“…A model for predicting the response of a conductimetric urea biosensor was developed and validated experimentally. The biosensor under consideration is formed…”
Get full text
Journal Article -
9
Electrical conductivity measurements using microfabricated interdigitated electrodes
Published in Analytical chemistry (Washington) (01-05-1993)“…A study constructed interdigitated electrode arrays to be used as miniature conductivity cells. Values resulting from conducted arrays agreed well with…”
Get full text
Journal Article -
10
Adhesion of polymer films to oxidized silicon and its effect on performance of a conductometric pH sensor
Published in Sensors and actuators. B, Chemical (1996)“…The use of a silane coupling agent, γ-methacryloxypropyl trimethoxysilane (γ-MPS), to promote adhesion of photolithographically patterned polymer hydrogels to…”
Get full text
Journal Article -
11
Microfabricated conductimetric pH sensor
Published in Sensors and actuators. B, Chemical (1995)“…A miniature conductimetric pH sensor has been developed, based on the measurement of the conductivity of a pH-responsive hydrogel. The microfabricated sensor…”
Get full text
Journal Article -
12
Micromachined silicon structures for modelling polymer matrix controlled release systems
Published in Journal of controlled release (01-10-1996)“…Physical models of polymer matrix controlled release systems were constructed by using silicon micromachining to fabricate miniature pore networks having…”
Get full text
Journal Article -
13
First-in-human testing of a wirelessly controlled drug delivery microchip
Published in Science translational medicine (22-02-2012)“…The first clinical trial of an implantable microchip-based drug delivery device is discussed. Human parathyroid hormone fragment (1-34) [hPTH(1-34)] was…”
Get more information
Journal Article -
14
Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device
Published in Nature biotechnology (01-04-2006)“…Implanted drug delivery systems are being increasingly used to realize the therapeutic potential of peptides and proteins. Here we describe the controlled…”
Get full text
Journal Article -
15
Electrothermally activated microchips for implantable drug delivery and biosensing
Published in Journal of controlled release (05-12-2005)“…Novel drug delivery and biosensing devices have the potential to increase the efficacy of drug therapy by providing physicians and patients the ability to…”
Get full text
Journal Article Conference Proceeding -
16
WP-B2 chemical reaction monitoring with the charge-flow transistor
Published in IEEE transactions on electron devices (01-11-1980)Get full text
Journal Article -
17
A method for studying swelling kinetics based on measurement of electrical conductivity
Published in Polymer gels and networks (01-04-1998)“…A novel method was applied to the study of swelling kinetics of pH-responsive hydrogels. This technique is based on the pH-dependent electrical conductivity of…”
Get full text
Journal Article -
18
The Second Report on the Teaching of Geometry
Published in Mathematical gazette (01-05-1939)Get full text
Journal Article -
19
Extracellular electrode model applied to the pancreatic beta cell
Published in Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (1994)“…A planar array of metal microelectrodes has been fabricated to measure the electrical activity of pancreatic beta cells. These cells secrete insulin and…”
Get full text
Conference Proceeding -
20
Model of a conductimetric urea sensor
Published in 1993 IEEE Annual Northeast Bioengineering Conference (1993)“…A model for predicting the response of a conductimetric urea sensor was developed. The sensor under consideration is formed by immobilizing the enzyme urease…”
Get full text
Conference Proceeding