Search Results - "Shandling, Adrian H."

Refine Results
  1. 1
  2. 2

    Thoracoscopic Microwave Epicardial Ablation: Feasibility for the Treatment of Idiopathic Sinus Node Tachycardia by Shandling, Adrian H., MD, Rieders, Daniel, MD, Bethencourt, Daniel M., MD

    Published in The Annals of thoracic surgery (2007)
    “…Inappropriate sinus tachycardia is a potentially debilitating condition with tachycardia emanating from the sinus node region. Endocardial radiofrequency…”
    Get full text
    Journal Article
  3. 3
  4. 4

    Use of a unique long pre-curved sheath to facilitate femoral placement of coronary sinus catheters by Shandling, Adrian H, Rieders, Daniel, Edwards, Melanie

    “…Catheterization of the coronary sinus (CS) from the femoral vein is widely used during electrophysiologic procedures. Access to the CS may be difficult. To…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Prevalence of patent foramen ovale in patients with acute myocardial infarction and angiographically normal coronary arteries by Crump, Randy, Shandling, Adrian H, Van Natta, Bruce, Ellestad, Myrvin

    Published in The American journal of cardiology (01-06-2000)
    “…There was no increased prevalence of patent foramen ovale in patients with myocardial infarction and normal coronary arteries. This suggests that paradoxical…”
    Get full text
    Journal Article
  7. 7

    The prevalence of cardiac ectopy in elderly patients with echocardiographically normal hearts is not increased by significant coronary artery disease by Shandling, Adrian H., Kern, Leslie, McAtee, Peggy, Switzenberg, Susan

    Published in Journal of electrocardiology (01-04-2006)
    “…A higher frequency of abnormal heart rhythms has previously been shown in elderly subjects with overtly normal hearts as demonstrated by noninvasive testing…”
    Get full text
    Journal Article
  8. 8

    Hyperbaric oxygen and thrombolysis in myocardial infarction: the 'HOT MI' randomized multicenter study by Stavitsky, Y, Shandling, A H, Ellestad, M H, Hart, G B, Van Natta, B, Messenger, J C, Strauss, M, Dekleva, M N, Alexander, J M, Mattice, M, Clarke, D

    Published in Cardiology (01-01-1998)
    “…In a previous pilot study, we demonstrated that adjunctive treatment with hyperbaric oxygen (HBO) appears to be feasible and safe in patients with acute…”
    Get more information
    Journal Article
  9. 9

    Efficacy of three-channel ambulatory electrocardiographic monitoring for the detection of myocardial ischemia by Shandling, A H, Bernstein, S B, Kennedy, H L, Ellestad, M H

    Published in The American heart journal (01-02-1992)
    “…The recognition of silent myocardial ischemia (SMI) has been demonstrated to have important clinical relevance. Two-channel ambulatory (Holter)…”
    Get more information
    Journal Article
  10. 10

    The influence of endocardial electrode fixation status on acute and chronic atrial stimulation threshold and atrial endocardial electrogram amplitude by Shandling, A H, Castellanet, M J, Thomas, L A, Messenger, J C

    Published in Pacing and clinical electrophysiology (01-09-1990)
    “…The endocardial atrial electrogram or "P wave amplitude" (PWA) and pacemaker atrial stimulation thresholds are important parameters determining correct pacing…”
    Get more information
    Journal Article
  11. 11
  12. 12

    Hyperbaric oxygen and thrombolysis in myocardial infarction: The "HOT MI" Pilot study by Shandling, Adrian H., Ellestad, Myrvin H., Hart, George B., Crump a, Randy, Marlow, David, Van Natta, Bruce, Messenger, John C., Strauss, Michael, Stavitsky, Yuri

    Published in The American heart journal (01-09-1997)
    “…Hyperbaric oxygen treatment (HBO) in combination with thrombolysis has been demonstrated to salvage myocardium in acute myocardial infarction in the animal…”
    Get full text
    Journal Article
  13. 13

    Influence of cardiac pacing mode on the long-term development of atrial fibrillation by Feuer, Joshua M., Shandling, Adrian H., Messenger, John C.

    Published in The American journal of cardiology (01-12-1989)
    “…The maintenance of sinus rhythm and atrioventricular (AV) synchrony is important to ensure optimal cardiac performance, reduce the potential for systemic…”
    Get full text
    Journal Article
  14. 14

    Analysis of the signal-averaged P-wave duration in patients with percutaneous coronary angioplasty-induced myocardial ischemia by Myrianthefs, Michael M., Shandling, Adrian H., Startt-Selvester, Ronald H., Bernstein, Stephen B., Crump, Randy, Lorenz, Linda M., Switzenberg, Susan, Ellestad, Myrvin H.

    Published in The American journal of cardiology (15-09-1992)
    “…To assess the impact of angioplasty-induced myocardial ischemia on the duration of the surface P wave, patients undergoing elective angioplasty of isolated…”
    Get full text
    Journal Article
  15. 15

    Diagnostic accuracy of predicting coronary artery disease related to patients' characteristics by Bobbio, M, Fubini, A, Detrano, R, Shandling, A H, Ellestad, M H, Clark, J, Brezden, O, Abecia, A, Martinez-Caro, D

    Published in Journal of clinical epidemiology (01-04-1994)
    “…Patients' demographic and clinical characteristics may affect diagnostic accuracy of cardiologists. We asked a group of experienced cardiologists from three…”
    Get more information
    Journal Article
  16. 16

    Altered ventricular repolarization in central sympathetic dysfunction associated with spinal cord injury by Lehmann, Kenneth G., Shandling, Adrian H., Yusi, Almira U., Froelicher, Victor F.

    Published in The American journal of cardiology (15-06-1989)
    “…Complete injury to the cervical spinal cord results in total disruption of central sympathetic outflow. Although ventricular repolarization can be…”
    Get full text
    Journal Article
  17. 17
  18. 18

    Clinical assessment of the probability of coronary artery disease: judgmental bias from personal knowledge by Bobbio, M, Detrano, R, Shandling, A H, Ellestad, M H, Clark, J, Brezden, O, Abecia, A, Martinez-Caro, D

    Published in Medical decision making (01-07-1992)
    “…Probability estimates of angiographic coronary artery disease made by experienced, board-certified staff cardiologists were compared with those of…”
    Get more information
    Journal Article
  19. 19

    Physical determinants of the endocardial P wave by Shandling, A H, Florio, J, Castellanet, M J, Messenger, J C, Crump, R, Evans, K, Rylaarsdam, A, Nolasco, M

    Published in Pacing and clinical electrophysiology (01-12-1990)
    “…Reliable atrial sensing of intrinsic P wave activity is important to ensure optimal atrial or dual chamber pacemaker function. Various physical factors (e.g.,…”
    Get more information
    Journal Article
  20. 20

    Alternate methods for the determination of atrial capture threshold utilizing the telemetered intracardiac electrogram by Feuer, J M, Florio, J, Shandling, A H

    Published in Pacing and clinical electrophysiology (01-10-1990)
    “…Periodic determination of pacemaker capture threshold is important to ensure appropriate pacemaker function. During dual chamber pacing, it is sometimes…”
    Get more information
    Journal Article