Search Results - "Shahnazi, K"

Refine Results
  1. 1

    Influence of beam efficiency through the patient-specific collimator on secondary neutron dose equivalent in double scattering and uniform scanning modes of proton therapy by Hecksel, D., Anferov, V., Fitzek, M., Shahnazi, K.

    Published in Medical physics (Lancaster) (01-06-2010)
    “…Purpose: Conventional proton therapy facilities use double scattering nozzles, which are optimized for delivery of a few fixed field sizes. Similarly, uniform…”
    Get full text
    Journal Article
  2. 2

    SU‐E‐T‐35: Extracting a Neutron Dose Using Only TLDs (Thermoluminescent Detectors) by Dy, A, Shahnazi, K, Klein, S

    Published in Medical Physics (01-06-2013)
    “…Purpose: To test the use of TLDs for out‐of‐field neutron measurements and demonstrate the calibration and calculations necessary to extract a neutron dose by…”
    Get full text
    Conference Proceeding Journal Article
  3. 3

    SU‐E‐T‐293: The Potential Application of High Energy Proton Beam‐Induced Positron for PET Imaging Technique by Barimah, E Kumi, Shahnazi, K, Keppel, C

    Published in Medical Physics (01-06-2012)
    “…Purpose: An existing nuclear interaction cross‐section of a positron emitter was used to predict range accuracy of proton beams and cross section of the…”
    Get full text
    Conference Proceeding Journal Article
  4. 4

    SU‐E‐T‐762: Dose Perturbation Studies Due to Prostate Seed Implants in Proton Uniform Scanned Beams by Nazaryan, V, DiGennaro, J, Shahnazi, K, Keppel, C

    Published in Medical Physics (01-06-2011)
    “…Purpose: To quantify dose perturbation in uniform scanned proton radiotherapy when used as a boost therapy following prostate seed implant. By comparing the…”
    Get full text
    Conference Proceeding Journal Article
  5. 5
  6. 6

    Calibration of a proton beam energy monitor by Moyers, M. F., Coutrakon, G. B., Ghebremedhin, A., Shahnazi, K., Koss, P., Sanders, E.

    Published in Medical physics (Lancaster) (01-06-2007)
    “…Delivery of therapeutic proton beams requires an absolute energy accuracy of ± 0.64 to 0.27 MeV for patch fields and a relative energy accuracy of ± 0.10 to…”
    Get full text
    Journal Article
  7. 7

    SU‐FF‐T‐459: The Effect of Proton Therapy Beam Scanning Pattern Size On Secondary Neutron Dose Equivalent by Hecksel, D, Anferov, V, Shahnazi, K, Fitzek, M

    Published in Medical Physics (01-06-2009)
    “…Purpose: One way to deliver a proton therapy beam is to actively scan a uniform dose across a treatment field using a fast scanning magnet. In this study, we…”
    Get full text
    Conference Proceeding Journal Article
  8. 8

    SU‐E‐T‐146: Uncertainty of Stopping Powers of Tissue Equivalent Materials in Uniformly Scanned Proton Beam by Butuceanu, C, Athar, B, Baillie, N, Duvvuri, S, Keppel, C, Lee, T, Nazaryan, V, Shahnazi, K

    Published in Medical Physics (01-06-2011)
    “…Purpose: To quantify uncertainties associated with the extraction of CT HU to stopping power conversion curve for tissue equivalent materials in uniformly…”
    Get full text
    Conference Proceeding Journal Article
  9. 9

    SU‐E‐T‐227: Patient Treatment Quality Assurance for a Uniformly Scanned Proton Therapy Beam by Baillie, N, Lee, T, Duvvuri, S, Shahnazi, K, Athar, B, Long, C, Butuceanu, C, Nazaryan, V, Keppel, C

    Published in Medical Physics (01-06-2011)
    “…Purpose: To describe the main quality assurance (QA) procedures undertaken at the Hampton University Proton Therapy Institute (HUPTI) in preparation for…”
    Get full text
    Conference Proceeding Journal Article
  10. 10

    SU‐GG‐T‐265: Stopping Power for Tissue Equivalent Materials and Hounsfield Numbers for Proton Radiation Treatment Planning: Calculation and Measurements by Ayan, A, Ainsley, C, Shahnazi, K, Garver, E, Both, S, Oliver, K, McDonough, J

    Published in Medical Physics (01-06-2010)
    “…Purpose: To generate a proton stopping power calibration curve from tissue equivalent materials combined with Hounsfield Unit (HU) values measured by an in…”
    Get full text
    Conference Proceeding Journal Article
  11. 11

    SU‐GG‐T‐596: Monitor Unit Verification of Proton Scattering Beam Using a Generic Beam Data by Zhu, T, Shen, J, Shahnazi, K, Slopsema, R, Both, S, McDonough, J

    Published in Medical Physics (01-06-2010)
    “…Purpose: We have developed an empirical algorithm to calculate patient specific monitor unit (MU) for Proton Scattering Beams. We examine the accuracy of MU…”
    Get full text
    Conference Proceeding Journal Article
  12. 12
  13. 13

    SU‐FF‐T‐328: Dose Perturbation and Range Shift with High‐Z Medium in Proton Beam by Das, I, Nichiporov, D, Moskvin, V, Shahnazi, K, Fanelli, L, Fitzek, M, Johnstone, P

    Published in Medical Physics (01-06-2009)
    “…Purpose: Treatment planning for proton beams requires accurate CT numbers to correlate with electron densities that define the proton range. When high atomic…”
    Get full text
    Conference Proceeding Journal Article
  14. 14

    SU‐FF‐T‐454: Impact of CT Number and Electron Density in Proton Dose Distribution by Kuros‐Zolnierczuk, J, Das, I, Shahnazi, K, Tasson, A, Allgower, C

    Published in Medical Physics (01-06-2009)
    “…Purpose: The dosimetric impact of different CT number to electron density calibrations used in proton beam treatment planning with emphasis on the dose…”
    Get full text
    Conference Proceeding Journal Article
  15. 15

    SU‐FF‐T‐255: Transmission of a Passive Double‐Scattered Proton Beam Through Brass by Pack, D, Shahnazi, K, Allen, B, Fitzek, M, Tasson, A, Reed, R

    Published in Medical Physics (01-06-2009)
    “…Purpose: To measure the depths reached in water by passive double‐scattered proton beams of three different energies after their transmission through various…”
    Get full text
    Conference Proceeding Journal Article
  16. 16

    SU‐FF‐T‐462: Treatment of Retinoblastoma Using Different Proton Delivery Methods: Scattering, Rectangular Scanning, and Circular Scanning by Shahnazi, K, Chang, A, Anferov, V, Hecksel, D, Thornton, A, Moyers, M, Fitzek, M

    Published in Medical Physics (01-06-2009)
    “…Purpose: The high risk of radiation induced malignancy in retinoblastoma with conventional radiotherapy makes treatment with proton beams advantageous since it…”
    Get full text
    Conference Proceeding Journal Article
  17. 17

    SU‐FF‐T‐456: A Comparison of Cysto‐Conray II to Readi‐Cat 2 Contrast Material for Use in Rectal Balloons During Proton Therapy by Tasson, A, Fitzek, M, Shahnazi, K, Simmons, J, Simoneaux, V, Speights, D, Sullivan‐Dickey, M, Thornton, A, Wallace, D

    Published in Medical Physics (01-06-2009)
    “…Purpose: In our clinic, a rectal balloon filled with contrast is used to fixate and localize the prostate during proton treatments. We have traditionally used…”
    Get full text
    Conference Proceeding Journal Article
  18. 18
  19. 19
  20. 20

    Issues in Proton Computed Tomography by Sadrozinski, H.F.-W., Bashkirov, V., Bruzzi, M., Johnson, L.R., Keeney, B., Ross, G., Schulte, R.W., Seiden, A., Shahnazi, K., Williams, D.C., Zhang, L.

    “…We report progress on a feasibility study of Proton Computed Tomography and Proton Transmission Radiography for applications in treatment planning and patient…”
    Get full text
    Journal Article