Search Results - "Serci, Sergio"
-
1
Fluctuations in radioactive decays. II. Experimental results
Published in Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics (01-01-1994)Get full text
Journal Article -
2
On the Limits of the Performances of Time-of-Flight Scintillator Hodoscopes Saving the Number of Photomultipliers
Published in IEEE transactions on nuclear science (01-01-1985)“…Results of measurements of the performances of a prototype of a time-of-flight scintillator hodoscope suited for neutron detection are described. The hodoscope…”
Get full text
Journal Article -
3
Real time compensation of the path spread in large time-of-flight systems
Published in IEEE transactions on nuclear science (01-02-1989)“…The operating principle of an electric system able to compensate in real time the differences in time-of-flight due to the path-length spread occurring in…”
Get full text
Journal Article -
4
A large volume low-level detector for measuring the gamma-radioactivity in water
Published in IEEE transactions on nuclear science (01-02-1988)“…The main features of a low-level large-volume detector for measuring in real time the gamma -radioactivity in water are described. The detector is made of…”
Get full text
Journal Article -
5
-
6
A Method for Calculating the Efficiency of Large Aperture Gas Cherenkov Counters
Published in IEEE transactions on nuclear science (01-01-1985)“…A method for calculating the efficiency of large aperture gas Cherenkov counters is presented. It is based on a careful Monte Carlo simulation of the…”
Get full text
Journal Article -
7
A Large Area, Fine Grained Neutron Hodoscope
Published in IEEE transactions on nuclear science (01-02-1986)“…Results of measurements of the performances of a time-of-flight neutron hodoscope consisting of 50 slabs of plastic scintillator, 100 × 2 × 5 cm3 each, are…”
Get full text
Journal Article -
8
A Low Energy Antineutron Detector
Published in IEEE transactions on nuclear science (01-01-1985)“…A detector for antineutrons in the momentum range 0.1 - 1 Gev/c, to be used at LEAR faci= lity at CERN, is described. The antineutrons are detected by means of…”
Get full text
Journal Article -
9
A Time-of-Flight Hodoscope Saving the Number of Photomultipliers
Published in IEEE transactions on nuclear science (01-01-1984)“…Results of measurements of the performances of a time-of-flight hodoscope consisting of 16 slabs of plastic scintillator, 90×4×1 cm3 each, viewed by only 8…”
Get full text
Journal Article