Search Results - "Schoene, S."

Refine Results
  1. 1

    From prompt gamma distribution to dose: a novel approach combining an evolutionary algorithm and filtering based on Gaussian-powerlaw convolutions by Schumann, A, Priegnitz, M, Schoene, S, Enghardt, W, Rohling, H, Fiedler, F

    Published in Physics in medicine & biology (07-10-2016)
    “…Range verification and dose monitoring in proton therapy is considered as highly desirable. Different methods have been developed worldwide, like particle…”
    Get more information
    Journal Article
  2. 2

    Requirements for a Compton camera for in vivo range verification of proton therapy by Rohling, H, Priegnitz, M, Schoene, S, Schumann, A, Enghardt, W, Hueso-González, F, Pausch, G, Fiedler, F

    Published in Physics in medicine & biology (07-04-2017)
    “…To ensure the optimal outcome of proton therapy, in vivo range verification is highly desired. Prompt γ-ray imaging (PGI) is a possible approach for in vivo…”
    Get more information
    Journal Article
  3. 3

    An outbreak of multi-drug-resistant Acinetobacter baumannii on a burns ICU and its control with multi-faceted containment measures by Obenhuber, T., Scheier, T.C., Stutz, T., Hug, M., Fontein, D., Kaiser, A., Schoene, S., Steiger, P., Brugger, S.D., Zingg, W., Schreiber, P.W.

    Published in The Journal of hospital infection (01-04-2024)
    “…Patients in burns centres are at high risk of acquiring multi-drug-resistant organisms (MDROs) due to the reduced skin barrier and long hospital stay. This…”
    Get full text
    Journal Article
  4. 4

    A Compton imager for in-vivo dosimetry of proton beams—A design study by Kormoll, T., Fiedler, F., Schöne, S., Wüstemann, J., Zuber, K., Enghardt, W.

    “…In-beam SPECT during therapeutic proton beam irradiation is a novel method for three dimensional in-vivo dose verification. For this purpose a Compton camera…”
    Get full text
    Journal Article
  5. 5
  6. 6
  7. 7
  8. 8
  9. 9

    A compton imaging prototype for range verification in particle therapy by Golnik, C., Fiedler, F., Heidel, K., Hueso Gonzalez, F., Kormoll, T., Pausch, G., Rohling, H., Schoene, S., Sobiella, M., Wagner, A., Enghardt, W.

    “…During the 2012 AAPM Annual Meeting 33 percent of the delegates considered the range uncertainty in proton therapy as the main obstacle of becoming a…”
    Get full text
    Conference Proceeding
  10. 10

    A prototype Compton camera for in-vivo dosimetry of ion beam cancer irradiation by Kormoll, T., Fiedler, F., Golnik, C., Heidel, K., Kempe, M., Schoene, S., Sobiella, M., Zuber, K., Enghardt, W.

    “…The promptly emitted photons during cancer ion beam treatment offer an additional possibility of dose monitoring that potentially overcomes some of the…”
    Get full text
    Conference Proceeding
  11. 11

    The use of prompt γ-rays for in-vivo dosimetry at therapeutic proton and ion beams by Fiedler, F., Dersch, U., Golnik, C., Kormoll, T., Muller, A., Rohling, H., Schone, S., Enghardt, W.

    “…Radiation therapy is an important treatment modality in cancer therapy. New radiation species like protons and light ions have the potential of increasing…”
    Get full text
    Conference Proceeding
  12. 12

    Compton imaging in a high energetic photon field by Kormoll, T., Golnik, C., Akhmadaliev, S., Bemmerer, D., Borany, J. V., Fiedler, F., Hueso Gonzalez, F., Heidel, K., Kempe, M., Rohling, H., Schmidt, K., Schone, S., Wagner, L., Pausch, G.

    “…Through the well defined range of charged particles in matter, cancer irradiation by means of ions can be very tumor conformal. However, external range…”
    Get full text
    Conference Proceeding
  13. 13

    Test of a compton imaging prototype at the ELBE bremsstrahlung beam by Hueso-González, F., Golnik, C., Berthel, M., Dreyer, A., Enghardt, W., Fiedler, F., Heidel, K., Kormoll, T., Rohling, H., Schöne, S., Schwengner, R., Wagner, A., Pausch, G.

    “…In the context of particle therapy, particle range verification is a major challenge for the quality assurance of the treatment. One approach is the…”
    Get full text
    Conference Proceeding
  14. 14
  15. 15

    A prototype compton camera for in-vivo dosimetry of ion beam cancer irradiation by Kormoll, T., Fiedler, F., Golnik, C., Heidel, K., Kempe, M., Schone, S., Sobiella, M., Zuber, K., Enghardt, W.

    “…Treedimensional in-vivo dose monitoring of ion beam cancer irradiation can improve the quality of treatment. For this purpose we investigate the feasibility of…”
    Get full text
    Conference Proceeding
  16. 16
  17. 17
  18. 18

    REVIEWS OF BOOKS by Schoene, S.

    Published in Africa (01-01-1932)
    Get full text
    Book Review
  19. 19
  20. 20

    Course of quantitative ventricular fibrillation waveform measure and outcome following out-of-hospital cardiac arrest by Schoene, Peter, MS, Coult, Jason, MS, Murphy, Lauren, BS, Fahrenbruch, Carol, MS, Blackwood, Jennifer, MPH, Kudenchuk, Peter, MD, FHRS, Sherman, Lawrence, MD, Rea, Thomas, MD

    Published in Heart rhythm (01-02-2014)
    “…Background Quantitative measures of the ventricular fibrillation waveform at the outset of resuscitation are associated with survival. However, little is known…”
    Get full text
    Journal Article