    The impact of air contaminants on humidifier membrane performance by Ilk, Daniel, Frick, Viktoria, Hänel, Christopher, Schiestel, Thomas, Schoemaker, Michael, Kraus, Holger, Hoster, Harry E.

    “…•Pollutants from the environment can damage humidifier membranes.•Polyimide and Fluoropolymer- membranes are degraded by ozone.•WTR of polysulfone-membranes is…”
    Get full text
    Journal Article
  2. 2

    How ozone traces degrade polyimide humidifier membranes for fuel cells by Ilk, Daniel, Frick, Viktoria, Hänel, Christopher, Götz, Tobias, Schiestel, Thomas, Schoemaker, Michael, Hoster, Harry E.

    Published in Next Energy (01-07-2024)
    “…Humidification of polymer electrolyte membranes in fuel cells is essential for high proton conductivity and lifetime, therefore often membrane humidifier…”
    Get full text
    Journal Article
  3. 3

    Evaluation of the Performance of a Novel System for Continuous Glucose Monitoring by Zschornack, Eva, Schmid, Christina, Pleus, Stefan, Link, Manuela, Klötzer, Hans-Martin, Obermaier, Karin, Schoemaker, Michael, Strasser, Monika, Frisch, Gerhard, Schmelzeisen-Redeker, Günther, Haug, Cornelia, Freckmann, Guido

    Published in Journal of diabetes science and technology (01-07-2013)
    “…Background: The performance of a continuous glucose monitoring (CGM) system in the early stage of development was assessed in an inpatient setting that…”
    Get full text
    Journal Article
  4. 4
  5. 5

    Benefits and Limitations of MARD as a Performance Parameter for Continuous Glucose Monitoring in the Interstitial Space by Heinemann, Lutz, Schoemaker, Michael, Schmelzeisen-Redecker, Günther, Hinzmann, Rolf, Kassab, Adham, Freckmann, Guido, Reiterer, Florian, Del Re, Luigi

    Published in Journal of Diabetes Science and Technology (01-01-2020)
    “…High-quality performance of medical devices for glucose monitoring is important for a safe and efficient usage of this diagnostic option by patients with…”
    Get full text
    Book Review Journal Article
  6. 6

    Significance and Reliability of MARD for the Accuracy of CGM Systems by Reiterer, Florian, Polterauer, Philipp, Schoemaker, Michael, Schmelzeisen-Redecker, Guenther, Freckmann, Guido, Heinemann, Lutz, del Re, Luigi

    Published in Journal of diabetes science and technology (01-01-2017)
    “…Background: There is a need to assess the accuracy of continuous glucose monitoring (CGM) systems for several uses. Mean absolute relative difference (MARD) is…”
    Get full text
    Journal Article
  7. 7

    Time Delay of CGM Sensors: Relevance, Causes, and Countermeasures by Schmelzeisen-Redeker, Günther, Schoemaker, Michael, Kirchsteiger, Harald, Freckmann, Guido, Heinemann, Lutz, del Re, Luigi

    Published in Journal of diabetes science and technology (04-08-2015)
    “…Background: Continuous glucose monitoring (CGM) is a powerful tool to support the optimization of glucose control of patients with diabetes. However, CGM…”
    Get full text
    Journal Article
  8. 8

    Gender differences in survival among adult patients starting antiretroviral therapy in South Africa: a multicentre cohort study by Cornell, Morna, Schomaker, Michael, Garone, Daniela Belen, Giddy, Janet, Hoffmann, Christopher J, Lessells, Richard, Maskew, Mhairi, Prozesky, Hans, Wood, Robin, Johnson, Leigh F, Egger, Matthias, Boulle, Andrew, Myer, Landon

    Published in PLoS medicine (01-09-2012)
    “…Increased mortality among men on antiretroviral therapy (ART) has been documented but remains poorly understood. We examined the magnitude of and risk factors…”
    Get full text
    Journal Article
  9. 9

    Combining Glucose Monitoring and Insulin Infusion in an Integrated Device: A Narrative Review of Challenges and Proposed Solutions by Schoemaker, Michael, Martensson, Anna, Mader, Julia K, Nørgaard, Kirsten, Freckmann, Guido, Benhamou, Pierre-Yves, Diem, Peter, Heinemann, Lutz

    Published in Journal of diabetes science and technology (05-10-2023)
    “…The introduction of automated insulin delivery (AID) systems has enabled increasing numbers of individuals with type 1 diabetes (T1D) to improve their glycemic…”
    Get full text
    Journal Article
  10. 10

    Rate-of-Change Dependence of the Performance of Two CGM Systems During Induced Glucose Swings by Pleus, Stefan, Schoemaker, Michael, Morgenstern, Karin, Schmelzeisen-Redeker, Günther, Haug, Cornelia, Link, Manuela, Zschornack, Eva, Freckmann, Guido

    Published in Journal of diabetes science and technology (01-07-2015)
    “…Introduction: The accuracy of continuous glucose monitoring (CGM) systems is often assessed with respect to blood glucose (BG) readings. CGM readings are…”
    Get full text
    Journal Article
  11. 11

    Performance Comparison of CGM Systems: MARD Values Are Not Always a Reliable Indicator of CGM System Accuracy by Kirchsteiger, Harald, Heinemann, Lutz, Freckmann, Guido, Lodwig, Volker, Schmelzeisen-Redeker, Günther, Schoemaker, Michael, del Re, Luigi

    Published in Journal of diabetes science and technology (01-09-2015)
    “…Background: The ongoing progress of continuous glucose monitoring (CGM) systems results in an increasing interest in comparing their performance, in particular…”
    Get full text
    Journal Article
  12. 12

    Performance Evaluations of Continuous Glucose Monitoring Systems: Precision Absolute Relative Deviation is Part of the Assessment by Obermaier, Karin, Schmelzeisen-Redeker, Günther, Schoemaker, Michael, Klötzer, Hans-Martin, Kirchsteiger, Harald, Eikmeier, Heino, del Re, Luigi

    Published in Journal of diabetes science and technology (01-07-2013)
    “…Background: Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose…”
    Get full text
    Journal Article
  13. 13

    Overview of a Novel Sensor for Continuous Glucose Monitoring by Schmelzeisen-Redeker, Günther, Staib, Arnulf, Strasser, Monika, Müller, Ulrich, Schoemaker, Michael

    Published in Journal of diabetes science and technology (01-07-2013)
    “…The core element of a continuous glucose monitoring (CGM) system is the glucose sensor, which should enable reliable CGM readings in the interstitial fluid in…”
    Get full text
    Journal Article
  14. 14

    Analysis of the Accuracy and Performance of a Continuous Glucose Monitoring Sensor Prototype: An In-Silico Study Using the UVA/PADOVA Type 1 Diabetes Simulator by Breton, Marc D., Hinzmann, Rolf, Campos-Nañez, Enrique, Riddle, Susan, Schoemaker, Michael, Schmelzeisen-Redeker, Guenther

    Published in Journal of diabetes science and technology (01-05-2017)
    “…Background: Computer simulation has been shown over the past decade to be a powerful tool to study the impact of medical devices characteristics on clinical…”
    Get full text
    Journal Article
  15. 15
  16. 16

    The lipoxygenase sensor, a new approach in essential fatty acid determination in foods by Schoemaker, Michael, Feldbrügge, Rainer, Gründig, Bernd, Friedrich Spener

    Published in Biosensors & bioelectronics (01-01-1997)
    “…Both an enzyme electrode and enzyme column with immobilized lipoxygenase, respectively, were used for the determination of essential fatty acids. The former…”
    Get full text
    Journal Article
  17. 17

    A novel method for continuous online glucose monitoring in humans: the comparative microdialysis technique by Hoss, U, Kalatz, B, Gessler, R, Pfleiderer, H J, Andreis, E, Rutschmann, M, Rinne, H, Schoemaker, M, Haug, C, Fussgaenger, R D

    “…The aim of this study was to prove the feasibility of continuous subcutaneous glucose monitoring in humans using the comparative microdialysis technique (CMT)…”