Evaluating the performance of electrocoagulation system in the removal of polystyrene microplastics from water

Emerging pollutants, particularly microplastics, present a significant threat to both the environment and human health. Traditional treatment methods lack targeted strategies for their removal. This study thoroughly investigated the efficacy of electrocoagulation as a method for efficiently extracti...

Full description

Saved in:
Bibliographic Details
Published in:Environmental research Vol. 243; p. 117887
Main Authors: Subair, Akhila, K L, Priya, Chellappan, Suchith, Rahuman A, Thamanna, Hridya, J., Devi, P.S., Salkka S, Mariyam, Indu, M.S., Pugazhendhi, Arivalagan, Chinglenthoiba, Chingakham
Format: Journal Article
Language:English
Published: Netherlands Elsevier Inc 15-02-2024
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Emerging pollutants, particularly microplastics, present a significant threat to both the environment and human health. Traditional treatment methods lack targeted strategies for their removal. This study thoroughly investigated the efficacy of electrocoagulation as a method for efficiently extracting microplastics from water. Various critical operational parameters, including electrode combinations, pH levels, electrolyte concentrations, electrode geometries, configurations, current intensities, and reaction times, were systematically examined. The study systematically examined the impact of different combinations of aluminium (Al) and stainless steel (SS) electrodes, including Al–Al, SS-SS, Al-SS, and SS-Al. Among these combinations, it was found that the Al–Al pairing exhibited outstanding efficiency in microplastic removal, while simultaneously minimizing energy consumption. Initial pH emerged as a critical parameter, with a neutral pH of 7 demonstrating the highest removal efficiency. In the pursuit of optimizing parameters like electrolyte concentrations, electrode geometry, and configuration, it's noteworthy that consistently achieving removal efficiencies exceeding 90% has been a significant achievement. However, to ascertain economic efficiency, additional factors such as energy consumption, electrode usage, and post-treatment conductivity must be taken into account. To tackle the complexity posed by various parameters and criteria, using multi-criteria decision-making tools like TOPSIS is essential, as it has a track record of effectiveness in practical applications. The electrolyte concentration of 0.5 g L−1 is identified as optimal by TOPSIS analysis Additionally, the TOPSIS highlighted the superiority of cylindrical hollow wire mesh electrodes and established the monopolar parallel configuration as the most effective electrode connection method. The investigation carefully evaluated the effect of reaction time, determining that a 50-min window provides optimal microplastic removal efficiency. This refined system exhibited remarkable proficiency in eliminating microplastics of varying size ranges (0–75 μm, 75–150 μm, and 150–300 μm), achieving removal efficiencies of 90.67%, 93.6%, and 94.6%, respectively, at input concentration of 0.2 g L−1. The present study offers a comprehensive framework for optimizing electrocoagulation parameters, presenting a practical and highly effective strategy to address the critical issue of microplastic contamination in aquatic environments. •Efficiency of electrocoagulation for removal of polystyrene microplastics evaluated.•Al–Al electrode showcased promising removal efficiency.•Cylindrical wire mesh electrode outperformed solid electrodes.•Larger sized microplastics exhibited higher removal.•TOPSIS tool applied for optimization of parameters.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0013-9351
1096-0953
DOI:10.1016/j.envres.2023.117887