Search Results - "Sale, Shiva"

Refine Results
  1. 1

    Hemodynamic evaluation of a new pulsatile blood pump during low flow cardiopulmonary bypass support by Miyamoto, Takuma, Sunagawa, Gengo, Dessoffy, Raymond, Karimov, Jamshid H., Grady, Patrick, Naber, Jeffrey P., Vincent, Douglas, Sale, Shiva M., Kvernebo, Knut, Tran, Van N. P., Moazami, Nader, Fukamachi, Kiyotaka

    Published in Artificial organs (01-04-2022)
    “…Background The VentriFlo® True Pulse Pump (VentriFlo, Inc, Pelham, NH, USA) is a new pulsatile blood pump intended for use during short‐term circulatory…”
    Get full text
    Journal Article
  2. 2

    A Comparison of Global Longitudinal, Circumferential, and Radial Strain to Predict Outcomes After Cardiac Surgery by Zhang, Kan, Sheu, Richard, Zimmerman, Nicole M., Alfirevic, Andrej, Sale, Shiva, Gillinov, A. Marc, Duncan, Andra E.

    “…Myocardial strain measured by speckle-tracking echocardiography detects subtle regional and global left ventricular dysfunction. Myocardial strain is measured…”
    Get full text
    Journal Article
  3. 3

    Using Near-Infrared Spectroscopy to Monitor Lower Extremities in Patients on Venoarterial Extracorporeal Membrane Oxygenation by Steffen, Robert J., MD, Sale, Shiva, MD, Anandamurthy, Balaram, MD, Cruz, Vincent B., BS, Grady, Patrick M., CCP, Soltesz, Edward G., MD, MPH, Moazami, Nader, MD

    Published in The Annals of thoracic surgery (01-11-2014)
    “…Patients on peripheral extracorporeal membrane oxygenation (ECMO) are at risk for lower extremity ischemia. Effective monitoring is needed to identify…”
    Get full text
    Journal Article
  4. 4
  5. 5

    Total artificial heart by Sale, Shiva M., M.D, Smedira, Nicholas G., M.D

    “…End-stage heart failure represents a highly morbid condition for the patient with limited treatment options. From a surgical perspective, the treatment options…”
    Get full text
    Journal Article
  6. 6
  7. 7

    Post-cardiopulmonary bypass longitudinal strain provides higher prognostic ability than baseline strain or change in strain by Wakefield, Brett, Artis, Amanda, Alfirevic, Andrej, Sale, Shiva, Duncan, Andra

    Published in Annals of cardiac anaesthesia (01-10-2022)
    “…Context: Global longitudinal strain (GLS) measured by speckle-tracking echocardiography demonstrates excellent prognostic ability in predicting major adverse…”
    Get full text
    Journal Article
  8. 8

    New Technology Mimics Physiologic Pulsatile Flow During Cardiopulmonary Bypass by Sunagawa, Gengo, Karimov, Jamshid H., Dessoffy, Raymond, Byram, Nicole, Grady, Patrick, Sinkewich, Martin, Naber, Jeffrey P., Vincent, Douglas, Okano, Shinji, Stewart, Robert D., Sale, Shiva M., Moazami, Nader, Fukamachi, Kiyotaka

    Published in Artificial organs (01-02-2018)
    “…The VentriFlo True Pulse Pump (Design Mentor, Inc., Pelham, NH, USA) is the first blood pump designed to mimic human arterial waveforms in a standard…”
    Get full text
    Journal Article
  9. 9

    Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves by Fukamachi, Kiyotaka, Karimov, Jamshid H., Sunagawa, Gengo, Horvath, David J., Byram, Nicole, Kuban, Barry D., Dessoffy, Raymond, Sale, Shiva, Golding, Leonard A. R., Moazami, Nader

    Published in Journal of artificial organs (01-12-2017)
    “…The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart…”
    Get full text
    Journal Article
  10. 10
  11. 11

    Continuous-flow total artificial heart: hemodynamic and pump-related changes associated with posture in a chronic calf model by Kado, Yuichiro, Byram, Nicole, Miyamoto, Takuma, Horvath, David J., Kuban, Barry D., Sale, Shiva, Fukamachi, Kiyotaka, Karimov, Jamshid H.

    Published in Journal of artificial organs (01-09-2019)
    “…This study aimed to evaluate the effects of posture (sitting [lying down]/standing) on hemodynamic and pump-related parameters in calves implanted with our…”
    Get full text
    Journal Article
  12. 12

    Novel technique for airless connection of artificial heart to vascular conduits by Karimov, Jamshid H., Gao, Shengqiang, Dessoffy, Raymond, Sunagawa, Gengo, Sinkewich, Martin, Grady, Patrick, Sale, Shiva, Moazami, Nader, Fukamachi, Kiyotaka

    Published in Journal of artificial organs (01-12-2017)
    “…Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting…”
    Get full text
    Journal Article
  13. 13
  14. 14

    Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant by Karimov, Jamshid H., Sunagawa, Gengo, Such, Kimberly A., Sale, Shiva, Golding, Leonard A. R., Moazami, Nader, Fukamachi, Kiyotaka

    Published in Journal of artificial organs (01-12-2015)
    “…The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program…”
    Get full text
    Journal Article
  15. 15
  16. 16
  17. 17
  18. 18
  19. 19
  20. 20