Search Results - "Salasca, S."
-
1
The WEST project: Testing ITER divertor high heat flux component technology in a steady state tokamak environment
Published in Fusion engineering and design (01-10-2014)“…The WEST project recently launched at Cadarache consists in transforming Tore Supra in an X-point divertor configuration while extending its long pulse…”
Get full text
Journal Article -
2
IR thermography diagnostics for the WEST project
Published in Fusion engineering and design (01-10-2014)“…•The WEST project requires a set of three infrared diagnostics.•The tungsten divertor will be monitored by the existing diagnostic renewed.•The antennas…”
Get full text
Journal Article -
3
Achievements on Engineering and Manufacturing of ITER First-Mirror Mock-ups
Published in IEEE transactions on plasma science (01-03-2012)“…Most of ITER optical diagnostics will be equipped with in-vessel metallic mirrors as plasma viewing components. These mirrors will be exposed to severe plasma…”
Get full text
Journal Article -
4
Impact of the layout of the ITER Radial Neutron Camera in-port system on the measurement of the neutron emissivity profile
Published in Fusion engineering and design (01-10-2013)“…► MCNP ITER model ‘Alite-4′ has been updated with the new Port Plug structure (three vertical drawers). ► Two different layouts for the Radial Neutron Camera…”
Get full text
Journal Article -
5
Neutronic analysis of the ITER Equatorial Port Plug 1
Published in Fusion engineering and design (01-08-2012)“…The ITER Equatorial Port 1 will host the following diagnostic systems: the Radial Neutron Camera (RNC), the High Resolution Neutron Spectrometer (HRNS), the…”
Get full text
Journal Article -
6
Progress on the Integration of ITER Diagnostics Equatorial Port Plugs in Europe
Published in IEEE transactions on plasma science (01-03-2012)“…Diagnostics in International Thermonuclear Experimental Reactor (ITER) are supported by big structures called port plugs, the second main function of which is…”
Get full text
Journal Article -
7
CEA engineering studies and integration of the ITER diagnostic port plugs
Published in Fusion engineering and design (01-10-2007)“…Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The…”
Get full text
Journal Article Conference Proceeding -
8
Engineering activities on the ITER representative diagnostic equatorial port plug
Published in Fusion engineering and design (01-06-2009)“…Most of ITER diagnostic systems are integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum vessel ports. The port…”
Get full text
Journal Article Conference Proceeding -
9
The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager
Published in Publications of the Astronomical Society of the Pacific (01-07-2015)“…In this article, we describe the Mid-Infrared Imager Module (MIRIM), which provides broadband imaging in the 5-27 μm wavelength range for the James Webb Space…”
Get full text
Journal Article -
10
On the operational specifications and associated R&D for the VIS/IR diagnostic for ITER
Published in 2009 1st International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (01-06-2009)“…The measurement requirements which have been defined for ITER are being associated to specific diagnostics for which they are guidelines for the development -…”
Get full text
Conference Proceeding -
11
The WEST Project: Challenges of Diagnostic Integration
Published in IEEE transactions on plasma science (01-05-2014)“…The W -for tungsten- environment in steady-state tokamak (WEST) project consists in transforming the French tokamak Tore Supra into an X-point divertor one and…”
Get full text
Journal Article -
12
Results of an integration study of a diagnostics port plug in ITER
Published in Fusion engineering and design (01-10-2013)“…► An extensive study on the integration of diagnostics in a port plug of ITER has been performed. ► It has shown that the diagnostic performances could not be…”
Get full text
Journal Article -
13
Diagnostic integration issues in the tore supra upgrade project WEST
Published in 2013 IEEE 25th Symposium on Fusion Engineering (SOFE) (01-06-2013)“…The WEST project (W - for tungsten - Environment in Steady-state Tokamak) consists in transforming the French tokamak Tore Supra into an X-point divertor one…”
Get full text
Conference Proceeding -
14
Achievements on engineering and manufacturing of ITER first mirrors mock-ups
Published in 2011 IEEE/NPSS 24th Symposium on Fusion Engineering (01-06-2011)“…Most of ITER optical diagnostics will be equipped with in-vessel metallic mirrors as plasma viewing components. These mirrors will be exposed to severe plasma…”
Get full text
Conference Proceeding -
15
Progress on the integration of ITER diagnostics equatorial port plugs in Europe
Published in 2011 IEEE/NPSS 24th Symposium on Fusion Engineering (01-06-2011)“…Diagnostics in ITER are supported by big structures called port plugs, the second main function of which is to ensure a sufficient shielding against neutrons…”
Get full text
Conference Proceeding -
16
The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager
Published 11-08-2015“…2015 Publications of the Astronomical Society of the Pacific, Volume 127, issue 953, pp.612-622 In this article, we describe the MIRI Imager module (MIRIM),…”
Get full text
Journal Article -
17
The ITER VIS/IR wide angle viewing system: Challenges and on-going R&D
Published in 2011 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (01-06-2011)“…The ITER tokamak is the next generation fusion device which will allow studying burning plasma obtained by a Deuterium-Tritium (D-T) fusion reaction during…”
Get full text
Conference Proceeding -
18
Study of the performance of ALICE slat chambers in the dimuon tracking system
Published in 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) (2001)“…The ALICE muon spectrometer will be employed to measure the production of vector mesons in Pb-Pb collisions. In this paper we show some results concerning a…”
Get full text
Conference Proceeding