Search Results - "Sakich, J."
-
1
Utilization of polymer enclosed intermediate class arresters to improve the performance of modern power systems
Published in IEEE transactions on power delivery (01-07-1992)“…The authors introduce the first commercially available polymer-enclosed intermediate class metal oxide surge arrester. The unique construction of the design,…”
Get full text
Journal Article -
2
Evaluation of leakage current pulse data of polymer insulator aging tests
Published in ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132) (1998)“…Non-ceramic (polymer) insulators have been employed by the electric utility industry for the last three decades. The electrical and material tests for polymer…”
Get full text
Conference Proceeding -
3
Evaluation of cumulative charge data of polymer insulator aging tests
Published in ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132) (1998)“…Polymer insulators have been employed by the electric utility industry for the last three decades. The three main components of the polymer insulators are the…”
Get full text
Conference Proceeding -
4
Salt fog aging tests on non-ceramic insulators and fog chamber data acquisition system
Published in Proceedings of Conference on Electrical Insulation and Dielectric Phenomena - CEIDP '96 (1996)“…Significant improvements in the quality and performance of non-ceramic insulators have been made in the 25 years since their introduction for use in high…”
Get full text
Conference Proceeding -
5
-
6
Final Report on the Clean Fog Test for HVAC Insulators
Published in IEEE transactions on power delivery (01-10-1987)“…The results of a program of tests carried out in a number of laboratories on artificially contaminated insulators using the clean fog method are reported and…”
Get full text
Journal Article Conference Proceeding -
7
Review of features of fog chamber at the Ohio State University for polymer insulator evaluation
Published in Proceedings of Conference on Electrical Insulation and Dielectric Phenomena - CEIDP '96 (1996)“…Non-ceramic (composite) insulators consist of a fiberglass core rod surrounded by a polymer weather-shed housing. The housing is generally manufactured from an…”
Get full text
Conference Proceeding -
8
-
9
The AC Clean-Fog Test for Contaminated Insulators
Published in IEEE transactions on power apparatus and systems (01-01-1983)“…The paper* summarizes the results of clean-fog tests conducted by eleven task-force laboratories on a common suspension insulator, IEEE insulator.** The test…”
Get full text
Journal Article -
10
Application of Insulators in a Contaminated Environment
Published in IEEE transactions on power apparatus and systems (01-09-1979)“…The application and maintenance of outdoor ceramic insulation on overhead transmission systems has been an art learned by experience. This document combines…”
Get full text
Journal Article -
11
Characterization of polymeric housing materials of non-ceramic insulators after aging tests
Published in Conference Record of the 1998 IEEE International Symposium on Electrical Insulation (Cat. No.98CH36239) (1998)“…A series of salt fog and UV aging tests were performed on non-ceramic insulators with different polymeric housing materials. The samples from the insulator…”
Get full text
Conference Proceeding -
12
Utilization of polymer enclosed intermediate class arresters to improve the performance of modern power systems
Published in Proceedings of the 1991 IEEE Power Engineering Society Transmission and Distribution Conference (1991)“…The first commercially available polymer enclosed intermediate class metal oxide surge arrester is introduced. The unique construction of the design is…”
Get full text
Conference Proceeding