Search Results - "Sahani, P K"

  • Showing 1 - 11 results of 11
Refine Results
  1. 1

    Application of XANES in gamma dosimetry by Sahani, P.K., Sinha, A.K., Haridas, G., Singh, M.N., Puntambekar, T.A.

    Published in Applied radiation and isotopes (01-07-2019)
    “…The thermoluminescence material, CaSO4:Dy, is widely used for the dosimetry of ionizing radiation due to its high sensitivity, low fading and wide dose range…”
    Get full text
    Journal Article
  2. 2

    Noninvasive assessment of cutaneous alterations in mice exposed to whole body gamma irradiation using optical imaging techniques by Sharma, P., Sahu, K., Kushwaha, P. K., Kumar, S., Swami, M. K., Kumawat, J., Patel, H. S., Kher, S., Sahani, P. K., Haridas, G., Gupta, P. K.

    Published in Lasers in medical science (01-09-2017)
    “…We report the results of a study carried out to investigate the potential of optical techniques such as optical coherence tomography, Mueller matrix…”
    Get full text
    Journal Article
  3. 3

    Simulations of photoneutron spectra due to incident high energy electrons on tungsten target using FLUKA by Sahani, P K, Haridas, G, Sarkar, P K

    Published in Indian journal of pure & applied physics (01-11-2012)
    “…Bremsstrahlung photons followed by photoneutrons are the major radiation hazards in high energy electron accelerators. These neutrons in high energy electron…”
    Get full text
    Journal Article
  4. 4

    Simulation of absorbed dose rate due to synchrotron radiation and shielding thickness for radiation safety at INDUS-2 using FLUKA by Sahani, P K, Haridas, G, Sarkar, P K

    Published in Indian journal of pure & applied physics (01-11-2012)
    “…Indus-2 is a 2.5 GeV electron synchrotron radiation source at Raja Ramanna Centre for Advanced Technology (RRCAT), India. 26 synchrotron radiation (SR) beam…”
    Get full text
    Journal Article
  5. 5

    Radiation safety aspects of the operation of first three synchrotron beam lines of Indus-2 by Nayak, M K, Nair, Haridas G, Bakshi, A K, Sahani, P K, Singh, Sunil, Khan, Saleem, Verma, Dimple, Dev, Vipin, Sahu, T K, Khare, Mukesh, Kumar, Vijay, Bandyopadhyay, Tapas, Tripathi, R M, Sharma, D N

    Published in Radiation protection dosimetry (01-04-2015)
    “…Five synchrotron radiation beam lines are commissioned and now under regular operation at the Synchrotron Radiation Source, Indus-2 at Raja Ramanna Centre For…”
    Get full text
    Journal Article
  6. 6

    Experimental determination of Bremsstrahlung dose rate due to accidental beam loss in Indus-1 storage ring by Haridas, G, Verma, D, Sahani, P K, Nayak, M K, Thakkar, K K, Sarkar, P K

    Published in Indian journal of pure & applied physics (01-07-2012)
    “…During the operation of an electron storage ring where electron beam is stored for the production of synchrotron radiation, probability of accidental beam loss…”
    Get full text
    Journal Article
  7. 7

    Photon and neutron dose evaluation in experimental hall of Indus-1 Synchrotron Radiation Source by Verma, Dimple, Sahu, T K, Khare, Mukesh, Dashora, S, Khan, Saleem, Nayak, M K, Sahani, P K, Haridas, G, Sarkar, P K

    Published in Indian journal of pure & applied physics (01-07-2012)
    “…Radiation measurement in Indus-1 experimental hall and Control Room area was performed for evaluating the photon and neutron dose rates during various…”
    Get full text
    Journal Article
  8. 8

    Experimental investigation of synchrotron and Bremsstrahlung dose at lithography beam line of Indus-2 SRS by Nayak, M K, Sahani, P K, Khare, Mukesh, Sahu, T K, Haridas, P, Dev, Vipin, Dashora, S, Dhamgaye, Vishal, Haridas, G, Sarkar, P K

    Published in Indian journal of pure & applied physics (01-11-2012)
    “…Measurement was performed during the initial trial operation of Lithography beam line (BL-07) of Indus-2 SRS. Transmission of SR through the beam line was…”
    Get full text
    Journal Article
  9. 9

    Radiation safety during the commissioning trials of synchrotron radiation beamlines of Indus-2 by Dev, Vipin, Nayak, M K, Sahani, P K, Verma, Dimple, Khare, Mukesh, Kumar, Vijay, Khan, Saleem, Sahu, T K, Dashora, S, Sinhamahapatra, Debasis, Haridas, G, Bakshi, A K, Mahant, A K, Marathe, R G, Singh, Gurnam, Sarkar, P K

    Published in Indian journal of pure & applied physics (01-11-2012)
    “…There are 26 synchrotron radiation beamlines planned to be installed in Indus-2 for various applications. 5 are commissioned, 2 are under commissioning trial…”
    Get full text
    Journal Article
  10. 10

    Residual radioactivity measurements at Indus accelerator complex by Verma, Dimple, Nayak, M K, Sahani, P K, Kumar, Vijay, Dev, Vipin, Khan, Saleem, Sahu, T K, Dashora, S, Khare, M, Mahapatra, D S, Haridas, G, Sarkar, P K

    Published in Indian journal of pure & applied physics (01-11-2012)
    “…Indus-1 and Indus-2 are two Synchrotron Radiation Sources (SRS) operational at RRCAT, Indore. During shut down of these accelerators for maintenance purpose,…”
    Get full text
    Journal Article
  11. 11

    Artillery Gun Recoil Measurement Using High-Speed Imaging and Image Processing Technique by Alam, Md M., Sahani, P K, Panda, H S, Biswal, T K

    “…The recoil of an artillery gun system is the rearward movement of the ordnance on firing relative to the mounting or carriage. Recoil system is an assembly…”
    Get full text
    Conference Proceeding