Search Results - "SKIPOR, ANASTASIA K"
-
1
Metal-on-metal Bearing Surfaces
Published in Journal of the American Academy of Orthopaedic Surgeons (01-02-2009)“…Metal-on-metal bearing couples remain a popular option in total hip arthroplasty and are the only currently available option for surface replacement…”
Get full text
Journal Article -
2
Do Ion Concentrations after Metal-on-Metal Hip Resurfacing Increase Over Time? A Prospective Study
Published in The Journal of arthroplasty (01-04-2013)“…Abstract Thirteen male and five female patients received a Conserve Plus hip resurfacing and prospectively provided blood samples to measure cobalt and…”
Get full text
Journal Article -
3
Metal Release in Patients Who Have Had a Primary Total Hip Arthroplasty. A Prospective, Controlled, Longitudinal Study
Published in Journal of bone and joint surgery. American volume (01-10-1998)“…There is an increasing recognition that, in the long term, total joint replacement may be associated with adverse local and remote tissue responses that are…”
Get full text
Journal Article -
4
Serum Metal Levels in Maxillofacial Reconstructive Surgery Patients: A Pilot Study
Published in Journal of oral and maxillofacial surgery (01-10-2018)“…The aim of this pilot study was to assay metal concentrations in the serum of patients who had undergone dental implant placement, orthognathic surgery using…”
Get full text
Journal Article -
5
Serum Metal Concentrations in Patients With Titanium Ceramic Composite Cervical Disc Replacements
Published in Spine (Philadelphia, Pa. 1976) (15-03-2017)“…Prospective longitudinal study. The serum titanium (Ti) concentrations were examined in patients implanted with a PRESTIGE LP Cervical Disc System (Medtronic,…”
Get full text
Journal Article -
6
Ten-Year Outcome of Serum Metal Ion Levels After Primary Total Hip Arthroplasty: A Concise Follow-up of a Previous Report
Published in Journal of bone and joint surgery. American volume (20-03-2013)“…We previously reported on the metal ion concentrations of cobalt, chromium, and titanium that were found in the serum of patients three years after they had…”
Get full text
Journal Article -
7
Nanoscale surface modification by anodic oxidation increased bone ingrowth and reduced fibrous tissue in the porous coating of titanium-alloy femoral hip arthroplasty implants
Published in Journal of biomedical materials research. Part B, Applied biomaterials (01-02-2017)“…Hip arthroplasty femoral stems coated with Ti6Al4V beads were treated by anodic oxidation in H PO for enhanced bioactivity and were studied in a 6-month canine…”
Get full text
Journal Article -
8
Metal degradation products: a cause for concern in metal-metal bearings?
Published in Clinical orthopaedics and related research (01-12-2003)“…In the majority of patients, orthopaedic implants are biocompatible. However, there is an increasing recognition that, in the long-term, permanent orthopaedic…”
Get more information
Journal Article -
9
Chromium and Nickel Concentrations in Subjects with a Stainless Steel Metal-on-Metal Cervical Disc Arthroplasty: Results from a Prospective Longitudinal Study with 7 Years Follow-Up
Published in International journal of spine surgery (01-08-2018)“…Cervical disc arthroplasty (CDA) has emerged as an alternative to anterior cervical discectomy and fusion for degenerative cervical disc disease. The…”
Get full text
Journal Article -
10
The Relationship Between Activity and Ions in Patients with Metal-on-Metal Bearing Hip Prostheses
Published in Journal of bone and joint surgery. American volume (01-04-2005)“…BackgroundTotal hip replacements with metal-on-metal bearings are frequently implanted in young, active patients. The relationship between patient activity and…”
Get full text
Journal Article -
11
Metal ion levels in maternal and placental blood after metal-on-metal total hip arthroplasty
Published in The American journal of orthopedics (Belle Mead, N.J.) (01-12-2014)“…There is concern regarding elevated metal ion levels in the blood during pregnancy and the potential fetal effects in women with metal-on-metal (MOM) implants…”
Get full text
Journal Article -
12
Serum Metal Ion Levels after Surgery in Patients with Metal-on-Metal Cervical Disc Arthroplasty: A Prospective Study Up to 84 Months
Published in The spine journal (01-10-2015)Get full text
Journal Article -
13
Can metal levels be used to monitor metal-on-metal hip arthroplasties?
Published in The Journal of arthroplasty (01-12-2004)“…In this review, the prospects for using blood, serum, and/or urine metal levels for monitoring the performance of metal-on-metal hip arthroplasty systems are…”
Get full text
Journal Article -
14
Effect of a second joint arthroplasty on metal ion levels after primary total hip arthroplasty
Published in The American journal of orthopedics (Belle Mead, N.J.) (01-10-2013)“…Serum metal ion levels increase after primary total hip arthroplasty (THA) regardless of bearing surface. We conducted a study to determine the effect of a…”
Get full text
Journal Article -
15
Serum and urine metal levels in patients with metal-on-metal surface arthroplasty
Published in Journal of materials science. Materials in medicine (01-12-2002)“…The resurgence of metal-on-metal articulating surfaces for hip arthroplasty has also heightened concerns about the degree and magnitude of metal particle…”
Get full text
Journal Article -
16
Autopsy Analysis Thirty Years After Metal-on-Metal Total Hip Replacement: A Case Report
Published in Journal of bone and joint surgery. American volume (01-11-2003)Get full text
Journal Article -
17
Metal release and excretion from cementless titanium alloy total knee replacements
Published in Clinical orthopaedics and related research (01-01-1999)“…Concentrations of titanium, aluminum, and vanadium were measured in the serum and urine of patients with titanium alloy cementless primary total knee…”
Get more information
Journal Article -
18
Serum Metal Levels and Bearing Surfaces in Total Hip Arthroplasty
Published in The Journal of arthroplasty (01-09-2006)“…This study evaluates steady-state serum metal levels in patients with 4 different combinations of fixation modalities, materials, and bearing couples. Forty…”
Get full text
Journal Article -
19
Metal Ion Levels in Maternal and Placental Blood Following Metal-on-Metal Arthroplasty
Published in The Journal of arthroplasty (2010)Get full text
Journal Article -
20
Focal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail
Published in Journal of bone and joint surgery. American volume (01-04-2001)“…Background:During routine follow-up of patients treated with a three-piece stainless-steel modular femoral nail, osteolysis and periosteal reaction around the…”
Get full text
Journal Article