Search Results - "SIQUEIRA, Dimytri"
-
1
-
2
Risk Stratification of New Persistent Left Bundle Branch Block After Transcatheter Aortic Valve Implantation
Published in The American journal of cardiology (15-07-2022)“…Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve…”
Get full text
Journal Article -
3
Predictive role of Selvester QRS score in patients undergoing transcatheter aortic valve replacement
Published in Catheterization and cardiovascular interventions (01-01-2021)“…Introduction Few data exist regarding the late clinical impact of the Selvester score prediction of myocardial fibrosis after transcatheter aortic valve…”
Get full text
Journal Article -
4
Mid‐ to long‐term clinical and echocardiographic outcomes after transcatheter aortic valve replacement with a new‐generation, self‐expandable system
Published in Catheterization and cardiovascular interventions (01-01-2021)“…Objectives The aim of the study was to evaluate mid‐ to late clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR) with…”
Get full text
Journal Article -
5
“Valve-In-Valve” Mitral por Via Transeptal: Um Papel de Destaque no Tratamento da Disfunção de Biopróteses no Brasil?
Published in Arquivos brasileiros de cardiologia (18-09-2020)Get full text
Journal Article -
6
Adapted Catheterization Laboratory Practices during the COVID-19 Pandemic: The Instituto Dante Pazzanese de Cardiologia Protocol
Published in Arquivos brasileiros de cardiologia (01-09-2020)Get full text
Journal Article -
7
Viability and Safety of Early Hospital Discharge after Minimalist TAVI in the Brazilian Unified Health System
Published in Arquivos brasileiros de cardiologia (01-01-2023)“…Central Illustration : Viability and Safety of Early Hospital Discharge after Minimalist TAVI in the Brazilian Unified Health System Results after…”
Get full text
Journal Article -
8
CLINICAL OUTCOMES OF A SECOND-GENERATION, SELF-EXPANDING TAVR SYSTEM: A SINGLE-CENTER EXPERIENCE
Published in Journal of the American College of Cardiology (05-04-2016)“…Conclusions In our experience, transcatheter aortic valve replacement with the new ACURATE neoTM was associated with good short- and mid-term clinical outcomes…”
Get full text
Journal Article -
9
Permanent Pacing After Transcatheter Aortic Valve Implantation: Incidence, Predictors and Evolution of Left Ventricular Function
Published in Arquivos brasileiros de cardiologia (01-12-2017)“…Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation…”
Get full text
Journal Article -
10
Late incomplete apposition after drug-eluting stent implantation: incidence and potential for adverse clinical outcomes
Published in European heart journal (01-06-2007)“…Aim Late-acquired incomplete stent apposition (ISA) has been documented after drug-eluting stent (DES) implantation; however, its clinical role remains…”
Get full text
Journal Article -
11
Prospective comparison between three TAVR devices: ACURATE neo vs. CoreValve vs. SAPIEN XT. A single heart team experience in patients with severe aortic stenosis
Published in Catheterization and cardiovascular interventions (01-07-2017)“…Objective We sought to compare the new transcatheter aortic valve replacement (TAVR) device ACURATE neo (ACT) with the already established CoreValve (MCV) and…”
Get full text
Journal Article -
12
Clinical Characteristics and Mid-Term follow-up of Elderly Patients with Severe Aortic Stenosis not Eligible for TAVI
Published in International journal of cardiovascular sciences (01-11-2021)“…Abstract Background: The treatment for symptomatic severe aortic stenosis (AS) is the correction of valve stenosis by surgical valve replacement and more…”
Get full text
Journal Article -
13
TCT-628 Prospective Non-randomized Comparison Between Three Transcatheter Aortic Valve Replacement Devices: Accurate vs Corevalve vs Sapien XT. A Single Heart Team Experience in Patients With Severe Aortic Stenosis
Published in Journal of the American College of Cardiology (13-10-2015)“…General n=162 ACCURATE n=48 CoreValve n=57 SAPIEN XT n=57 p Age (y) 82.63±6.55 82.29±5.33 82.39±7.72 83.14±6.32 0.75 Male (n) 45.7% (74) 45.8% (22) 45.6% (26)…”
Get full text
Journal Article -
14
TCT-624 Acute Renal Injury and Mortality After Transcatheter Aortic Valve Replacement
Published in Journal of the American College of Cardiology (13-10-2015)“…Regarding long term follow-up, AKI (HR 19.86, CI 95% 7.31-53.98, p <0.001) and COPD (HR 3.14, IC 95% 1.05-9.40, p = 0.04) were independent risk factors for…”
Get full text
Journal Article -
15
TCT-668 Transcatheter aortic valve implantation in degenerated aortic bioprosthesis: an analysis from the Brazilian TAVI Registry
Published in Journal of the American College of Cardiology (13-10-2015)“…Background Valve-in-valve TAVI (ViV-TAVI) has emerged as a promising modality for high-risk patients with degenerated aortic bioprostheses in order to avoid a…”
Get full text
Journal Article -
16
Balloon‐expandable versus self‐expanding valves for transcatheter aortic valve replacement using new generation devices: An analysis of the Brazilian RIBAC‐NT registry
Published in Catheterization and cardiovascular interventions (01-09-2024)“…Background Conflicting data yet exists regarding the clinical outcomes of transcatheter aortic valve replacement (TAVR) using balloon‐expandable (BEV) and…”
Get full text
Journal Article -
17
TCT-640 MGuardTM Stent Reduces Early Adverse Events In Saphenous Vein Graft Percutaneous Coronary Intervention
Published in Journal of the American College of Cardiology (16-09-2014)Get full text
Journal Article -
18
TCT-583 Longest available clinical follow-up of a cohort of “real-world” patients treated exclusively with drug-eluting stents: Results of 12 years of the DESIRE (Drug-Eluting Stents In the REal world) Registry
Published in Journal of the American College of Cardiology (16-09-2014)“…Independent predictors of ST were PCI for STEMI (HR 3.5; 95% CI, 1.3 to 9.4, p= 0.013), stent length (HR 1.8; 95% CI, 1.09 to 3.02, p=0.023), moderate/severe…”
Get full text
Journal Article -
19
TCT-389 Reproducibility of Intracoronary Frequency-Domain Optical Coherence Tomography Quantitative Analysis Using Two Different Software Packages
Published in Journal of the American College of Cardiology (16-09-2014)“…Background Current frequency-domain optical coherence tomography (FD-OCT) systems acquire a large amount of data (100 frames/s) during long scans (54 mm) of…”
Get full text
Journal Article -
20
Progression and Prognosis of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
Published in Arquivos brasileiros de cardiologia (01-12-2017)“…BACKGROUNDThe impact of paravalvular regurgitation (PVR) following transcatheter aortic valve implantation (TAVI) remains uncertain.OBJECTIVETo evaluate the…”
Get full text
Journal Article