Search Results - "Španěl, Patrik"
-
1
Progress in SIFT-MS: Breath analysis and other applications
Published in Mass spectrometry reviews (01-03-2011)“…The development of selected ion flow tube mass spectrometry, SIFT-MS, is described from its inception as the modified very large SIFT instruments used to…”
Get full text
Journal Article -
2
Selected Ion Flow-Drift Tube Mass Spectrometry: Quantification of Volatile Compounds in Air and Breath
Published in Analytical chemistry (Washington) (15-12-2015)“…A selected ion flow-drift tube mass spectrometric analytical technique, SIFDT-MS, is described that extends the established selected ion flow tube mass…”
Get full text
Journal Article -
3
Ambient analysis of trace compounds in gaseous media by SIFT-MS
Published in Analyst (London) (21-05-2011)“…The topic of ambient gas analysis has been rapidly developed in the last few years with the evolution of the exciting new techniques such as DESI, DART and…”
Get more information
Journal Article -
4
Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis
Published in Mass spectrometry reviews (01-09-2005)“…Selected ion flow tube mass spectrometry (SIFT‐MS) is a new analytical technique for the real‐time quantification of several trace gases simultaneously in air…”
Get full text
Journal Article -
5
Electrostatic Switching and Selection of H3O+, NO+, and O2 +• Reagent Ions for Selected Ion Flow-Drift Tube Mass Spectrometric Analyses of Air and Breath
Published in Analytical chemistry (Washington) (16-04-2019)“…Soft chemical ionization mass spectrometry techniques, particularly the well-established proton transfer reaction mass spectrometry, PTR-MS, and selected ion…”
Get full text
Journal Article -
6
A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS
Published in Physiological measurement (01-04-2006)“…Selected ion flow tube mass spectrometry, SIFT-MS, has been used to monitor the volatile compounds in the exhaled breath of 30 volunteers (19 males, 11…”
Get more information
Journal Article -
7
The challenge of breath analysis for clinical diagnosis and therapeutic monitoring
Published in Analyst (London) (01-01-2007)“…The potential of breath analysis for clinical diagnosis and the strengths and weaknesses of the analytical methods used are discussed. Special attention is…”
Get more information
Journal Article -
8
A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry
Published in Rapid communications in mass spectrometry (01-01-2006)“…Selected‐ion flow‐tube mass spectrometry (SIFT‐MS) has been used to monitor the volatile compounds in the exhaled breath of 30 volunteers (19 male, 11 female)…”
Get full text
Journal Article -
9
A selected ion flow tube mass spectrometry study of ammonia in mouth- and nose-exhaled breath and in the oral cavity
Published in Rapid communications in mass spectrometry (30-03-2008)“…A study has been carried out, involving three healthy volunteers, of the ammonia levels in breath exhaled via the mouth and via the nose and in the static oral…”
Get full text
Journal Article -
10
Increase of the Charge Transfer Rate Coefficients for NO+ and O2 +• Reactions with Isoprene Molecules at Elevated Interaction Energies
Published in The journal of physical chemistry. A, Molecules, spectroscopy, kinetics, environment, & general theory (27-12-2018)“…Atmospheric concentrations of isoprene (2-methylbutadiene) in environmental research and in exhaled breath for medical research are usually measured by soft…”
Get full text
Journal Article -
11
A longitudinal study of methanol in the exhaled breath of 30 healthy volunteers using selected ion flow tube mass spectrometry, SIFT-MS
Published in Physiological measurement (01-07-2006)“…Selected ion flow tube mass spectrometry, SIFT-MS, has been used to monitor the volatile compounds in the exhaled breath of 30 volunteers (19 male, 11 female)…”
Get more information
Journal Article -
12
A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
Published in Physiological measurement (01-01-2006)“…Thirty volunteers (19 males, 11 females) were recruited for a 6-month study of the volatile compounds in their exhaled breath using the selected ion flow tube…”
Get more information
Journal Article -
13
Breath analysis of ammonia, volatile organic compounds and deuterated water vapor in chronic kidney disease and during dialysis
Published in Bioanalysis (01-03-2014)“…The volatile metabolites present in trace amounts in exhaled breath of healthy individuals and patients, for example those with advanced chronic kidney disease…”
Get full text
Journal Article -
14
Acetone, butanone, pentanone, hexanone and heptanone in the headspace of aqueous solution and urine studied by selected ion flow tube mass spectrometry
Published in Rapid communications in mass spectrometry (30-04-2009)“…Urine is commonly analysed in clinical practice by a variety of liquid‐phase techniques to check for excessive ketone bodies, proteins and salts to name just a…”
Get full text
Journal Article -
15
Effects of dietary nutrients on volatile breath metabolites
Published in Journal of nutritional science (Cambridge) (2013)“…Breath analysis is becoming increasingly established as a means of assessing metabolic, biochemical and physiological function in health and disease. The…”
Get full text
Journal Article -
16
Mass Spectrometric Quantification of Volatile Compounds Released by Fresh Atlantic Salmon Stored at 4 °C under Modified Atmosphere Packaging and Vacuum Packaging for up to 16 Days
Published in ACS food science & technology (18-03-2022)“…Atlantic salmon is rich in bioactive proteins, antioxidants, vitamins, and omega-3 fatty acids, making it a rich source of essential nutrients. However, it is…”
Get full text
Journal Article -
17
Selected ion flow tube mass spectrometry of exhaled breath condensate headspace
Published in Rapid communications in mass spectrometry (30-09-2008)“…Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would…”
Get full text
Journal Article -
18
Understanding Gas Phase Ion Chemistry Is the Key to Reliable Selected Ion Flow Tube-Mass Spectrometry Analyses
Published in Analytical chemistry (Washington) (06-10-2020)“…Ion–molecule reactions (IMR) are at the very core of trace gas analyses in modern chemical ionization (CI) mass spectrometer instruments, which are…”
Get full text
Journal Article -
19
Gas‐phase ion mobility of protonated aldehydes in helium measured using a selected ion flow‐drift tube
Published in Rapid communications in mass spectrometry (01-07-2024)“…Rationale In soft chemical ionization mass spectrometry, analyte ions are produced via ion–molecule reactions in the reactor. When an electric field E is…”
Get full text
Journal Article -
20
Selected Ion Flow Tube Study of Ion–Molecule Reactions of N+(3P) and Kr+ with C3 Hydrocarbons Propane, Propene, and Propyne
Published in The journal of physical chemistry. A, Molecules, spectroscopy, kinetics, environment, & general theory (30-06-2011)“…Reactions of 14N+(3P), 15N+(3P), and Kr+ with propane, propene, and propyne were studied using the selected ion flow tube, SIFT, technique. Thermal rate…”
Get full text
Journal Article