Search Results - "Ruhm, Loreen"
-
1
Mapping of glutamate metabolism using 1H FID-MRSI after oral administration of [1-13C]Glc at 9.4 T
Published in NeuroImage (Orlando, Fla.) (15-04-2023)“…•Labeling effects in metabolites after oral intake of [1-13C]Glc in human brain.•High temporal and spatial resolution could be achieved using 1H-FID-MRSI at…”
Get full text
Journal Article -
2
Deuterium metabolic imaging in the human brain at 9.4 Tesla with high spatial and temporal resolution
Published in NeuroImage (Orlando, Fla.) (01-12-2021)“…To present first highly spatially resolved deuterium metabolic imaging (DMI) measurements of the human brain acquired with a dedicated coil design and a fast…”
Get full text
Journal Article -
3
Feasibility of deuterium magnetic resonance spectroscopy of 3-O-Methylglucose at 7 Tesla
Published in PloS one (07-06-2021)“…Deuterium Magnetic Resonance Spectroscopy (DMRS) is a non-invasive technique that allows the detection of deuterated compounds in vivo. DMRS has a large…”
Get full text
Journal Article -
4
Improving the Effective Spatial Resolution in 1H-MRSI of the Prostate with Three-Dimensional Overdiscretized Reconstructions
Published in Life (Basel, Switzerland) (19-01-2023)“…In in vivo 1H-MRSI of the prostate, small matrix sizes can cause voxel bleeding extending to regions far from a voxel, dispersing a signal of interest outside…”
Get full text
Journal Article -
5
Measurement of glucose metabolism in the occipital lobe and frontal cortex after oral administration of [1-13C]glucose at 9.4 T
Published in Journal of cerebral blood flow and metabolism (01-10-2022)“…For the first time, labeling effects after oral intake of [1-13C]glucose are observed in the human brain with pure 1H detection at 9.4 T. Spectral time series…”
Get full text
Journal Article -
6
Mapping of glutamate metabolism using 1H FID-MRSI after oral administration of 1-13CGlc at 9.4 T
Published in NeuroImage (Orlando, Fla.) (15-04-2023)“…Glutamate is the major excitatory transmitter in the brain and malfunction of the related metabolism is associated with various neurological diseases and…”
Get full text
Journal Article -
7
Comparison of four 31P single‐voxel MRS sequences in the human brain at 9.4 T
Published in Magnetic resonance in medicine (01-06-2021)“…Purpose In this study, different single‐voxel localization sequences were implemented and systematically compared for the first time for phosphorous MRS…”
Get full text
Journal Article -
8
Phosphorus transversal relaxation times and metabolite concentrations in the human brain at 9.4 T
Published in NMR in biomedicine (01-10-2022)“…A method to estimate phosphorus (31P) transversal relaxation times (T2s) of coupled spin systems is demonstrated. Additionally, intracellular and extracellular…”
Get full text
Journal Article -
9
Unshielded bent folded‐end dipole 9.4 T human head transceiver array decoupled using modified passive dipoles
Published in Magnetic resonance in medicine (01-07-2021)“…Purpose To develop an unshielded dipole transceiver array for human head imaging at 9.4 Tesla and to improve decoupling of adjacent dipole elements, a novel…”
Get full text
Journal Article -
10
3D 31P MRSI of the human brain at 9.4 Tesla: Optimization and quantitative analysis of metabolic images
Published in Magnetic resonance in medicine (01-11-2021)“…Purpose To present 31P whole brain MRSI with a high spatial resolution to probe quantitative tissue analysis of 31P MRSI at an ultrahigh field strength of 9.4…”
Get full text
Journal Article -
11
Joint learning of nonlinear representation and projection for fast constrained MRSI reconstruction
Published in Magnetic resonance in medicine (04-09-2024)“…To develop and evaluate a novel method for computationally efficient reconstruction from noisy MR spectroscopic imaging (MRSI) data. The proposed method…”
Get full text
Journal Article -
12
Bent folded‐end dipole head array for ultrahigh‐field MRI turns “dielectric resonance” from an enemy to a friend
Published in Magnetic resonance in medicine (01-12-2020)“…Purpose To provide transmit whole‐brain coverage at 9.4 T using an array with only eight elements and improve the specific absorption rate (SAR) performance, a…”
Get full text
Journal Article -
13
A 32‐element loop/dipole hybrid array for human head imaging at 7 T
Published in Magnetic resonance in medicine (01-10-2022)“…Purpose To improve whole‐brain SNR at 7 Tesla, a novel 32‐element hybrid human head array coil was developed, constructed, and tested. Methods Our general…”
Get full text
Journal Article -
14
Decoupling of folded‐end dipole antenna elements of a 9.4 T human head array using an RF shield
Published in NMR in biomedicine (01-09-2020)“…Dipole antennas have recently been introduced to the field of MRI and successfully used, mostly as elements of ultra‐high field (UHF, ≥ 7 T) human body arrays…”
Get full text
Journal Article -
15
Evaluation of short folded dipole antennas as receive elements of ultra‐high‐field human head array
Published in Magnetic resonance in medicine (01-08-2019)“…Purpose To improve the receive (Rx) performance of a human head transceiver (TxRx) array at 9.4T without compromising its transmit (Tx) performance, a novel…”
Get full text
Journal Article -
16
3D 31 P MRSI of the human brain at 9.4 Tesla: Optimization and quantitative analysis of metabolic images
Published in Magnetic resonance in medicine (01-11-2021)“…PURPOSETo present 31 P whole brain MRSI with a high spatial resolution to probe quantitative tissue analysis of 31 P MRSI at an ultrahigh field strength of 9.4…”
Get full text
Journal Article -
17
9.4T double‐tuned 13C/1H human head array using a combination of surface loops and dipole antennas
Published in NMR in biomedicine (01-10-2021)“…MRI at ultra‐high field (UHF, ≥7 T) provides a natural strategy for improving the quality of X‐nucleus magnetic resonance spectroscopy and imaging due to the…”
Get full text
Journal Article -
18
9.4 T double-tuned 13 C/ 1 H human head array using a combination of surface loops and dipole antennas
Published in NMR in biomedicine (01-10-2021)“…MRI at ultra-high field (UHF, ≥7 T) provides a natural strategy for improving the quality of X-nucleus magnetic resonance spectroscopy and imaging due to the…”
Get full text
Journal Article -
19
9.4 T double‐tuned 13C/1H human head array using a combination of surface loops and dipole antennas
Published in NMR in biomedicine (01-10-2021)“…MRI at ultra‐high field (UHF, ≥7 T) provides a natural strategy for improving the quality of X‐nucleus magnetic resonance spectroscopy and imaging due to the…”
Get full text
Journal Article -
20
Double-tuned 31 P/ 1 H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T
Published in Magnetic resonance in medicine (01-08-2020)“…To develop a robust design of a human head double-tuned P/ H array, which provides good performance at both P and H frequencies for MR spectroscopic imaging at…”
Get full text
Journal Article