Search Results - "Rubin, G D"

Refine Results
  1. 1

    Multi-detector row CT angiography of lower extremity arterial inflow and runoff: initial experience by Rubin, G D, Schmidt, A J, Logan, L J, Sofilos, M C

    Published in Radiology (01-10-2001)
    “…To assess the patterns of lower extremity arterial inflow and runoff opacification with four-channel multi-detector row computed tomographic (CT) angiography…”
    Get more information
    Journal Article
  2. 2

    Perspective volume rendering of CT and MR images: applications for endoscopic imaging by Rubin, G D, Beaulieu, C F, Argiro, V, Ringl, H, Norbash, A M, Feller, J F, Dake, M D, Jeffrey, R B, Napel, S

    Published in Radiology (01-05-1996)
    “…To use perspective volume rendering (PVR) of computed tomographic (CT) and magnetic resonance (MR) imaging data sets to simulate endoscopic views of human…”
    Get more information
    Journal Article
  3. 3

    Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography by Fleischmann, D, Rubin, G D, Bankier, A A, Hittmair, K

    Published in Radiology (01-02-2000)
    “…To compare the uniformity of aortoiliac opacification obtained from uniphasic contrast medium injections versus individualized biphasic injections at computed…”
    Get more information
    Journal Article
  4. 4

    Unsuspected pulmonary embolism: prospective detection on routine helical CT scans by Gosselin, M V, Rubin, G D, Leung, A N, Huang, J, Rizk, N W

    Published in Radiology (01-07-1998)
    “…To determine the prevalence of unsuspected pulmonary embolism (PE) on routine thoracic helical computed tomographic (CT) scans and to quantify the improvement…”
    Get more information
    Journal Article
  5. 5

    Measurement of the aorta and its branches with helical CT by Rubin, G D, Paik, D S, Johnston, P C, Napel, S

    Published in Radiology (01-03-1998)
    “…Contiguous orthonormal arterial cross sections, segment lengths, and curvature were semiautomatically quantified from helical computed tomographic (CT)…”
    Get more information
    Journal Article
  6. 6

    Detection of ureteral calculi in patients with suspected renal colic: value of reformatted noncontrast helical CT by Sommer, FG, Jeffrey, RB, Jr, Rubin, GD, Napel, S, Rimmer, SA, Benford, J, Harter, PM

    Published in American journal of roentgenology (1976) (01-09-1995)
    “…The purpose of this study was to determine the value of reformatted noncontrast helical CT in patients with suspected renal colic. We hoped to determine…”
    Get full text
    Journal Article Conference Proceeding
  7. 7

    Three-dimensional spiral CT angiography of the abdomen: initial clinical experience by Rubin, G D, Dake, M D, Napel, S A, McDonnell, C H, Jeffrey, Jr, R B

    Published in Radiology (01-01-1993)
    “…Spiral computed tomography (CT) is a new technology that couples continuous tube rotation with continuous table feed. This allows compilation of a data set…”
    Get more information
    Journal Article
  8. 8
  9. 9

    Spiral CT of renal artery stenosis: comparison of three-dimensional rendering techniques by Rubin, G D, Dake, M D, Napel, S, Jeffrey, Jr, R B, McDonnell, C H, Sommer, F G, Wexler, L, Williams, D M

    Published in Radiology (01-01-1994)
    “…To evaluate the accuracy of computed tomographic (CT) angiography in the detection of renal artery stenosis (RAS). CT angiography was performed in 31 patients…”
    Get more information
    Journal Article
  10. 10

    CT angiography with spiral CT and maximum intensity projection by Napel, S, Marks, M P, Rubin, G D, Dake, M D, McDonnell, C H, Song, S M, Enzmann, D R, Jeffrey, Jr, R B

    Published in Radiology (01-11-1992)
    “…The authors describe a technique for obtaining angiographic images by means of spiral computed tomography (CT), preprocessing of reconstructed…”
    Get more information
    Journal Article
  11. 11

    Aortic aneurysmal disease: assessment of stent-graft treatment-CT versus conventional angiography by Armerding, M D, Rubin, G D, Beaulieu, C F, Slonim, S M, Olcott, E W, Samuels, S L, Jorgensen, M J, Semba, C P, Jeffrey, Jr, R B, Dake, M D

    Published in Radiology (01-04-2000)
    “…To compare computed tomographic (CT) angiography and conventional angiography for determining the success of endoluminal stent-graft treatment of aortic…”
    Get more information
    Journal Article
  12. 12

    Computed tomographic angiography : Historical perspective and new state-of-the-art using multi detector-row helical computed tomography by RUBIN, G. D, SHIAU, M. C, SCHMIDT, A. J, FLEISCHMANN, D, LOGAN, L, LEUNG, A. N, JEFFREY, R. B, NAPEL, S

    Published in Journal of computer assisted tomography (01-11-1999)
    “…Since its clinical introduction in 1991, volumetric computed tomography scanning using spiral or helical scanners has resulted in a revolution for diagnostic…”
    Get full text
    Conference Proceeding Journal Article
  13. 13

    Assessment of living renal donors with spiral CT by Rubin, G D, Alfrey, E J, Dake, M D, Semba, C P, Sommer, F G, Kuo, P C, Dafoe, D C, Waskerwitz, J A, Bloch, D A, Jeffrey, R B

    Published in Radiology (01-05-1995)
    “…To determine whether spiral computed tomography (CT) can be used to evaluate potential living renal donors. Twelve potential living renal donors underwent…”
    Get more information
    Journal Article
  14. 14

    Stair-step artifacts with single versus multiple detector-row helical CT by Fleischmann, D, Rubin, G D, Paik, D S, Yen, S Y, Hilfiker, P R, Beaulieu, C F, Napel, S

    Published in Radiology (01-07-2000)
    “…To compare the effects of acquisition parameters on the magnitude and appearance of artifacts between single and multiple detector-row helical computed…”
    Get more information
    Journal Article
  15. 15

    Three-dimensional helical CT angiography by Rubin, G D

    Published in Radiographics (01-07-1994)
    “…CT angiography can accurately depict vascular lesions in less time, with less patient morbidity, and at a lower cost than conventional angiography. Meticulous…”
    Get more information
    Journal Article
  16. 16

    Thoracic spiral CT: influence of subsecond gantry rotation on image quality by Rubin, G D, Leung, A N, Robertson, V J, Stark, P

    Published in Radiology (01-09-1998)
    “…To determine if the lower milliampere second setting and shorter acquisition time of subsecond spiral computed tomography (CT) affects the image quality of…”
    Get more information
    Journal Article
  17. 17

    Iliac arterial injuries after endovascular repair of abdominal aortic aneurysms: correlation with iliac curvature and diameter by Tillich, M, Bell, R E, Paik, D S, Fleischmann, D, Sofilos, M C, Logan, L J, Rubin, G D

    Published in Radiology (01-04-2001)
    “…To determine the relationship between iliac arterial tortuosity and cross-sectional area and the occurrence of iliac arterial injuries following transfemoral…”
    Get more information
    Journal Article
  18. 18

    Helical CT of the urinary tract by Fielding, JR, Silverman, SG, Rubin, GD

    Published in American journal of roentgenology (1976) (01-05-1999)
    “…The advent of helical CT has changed the practice of uroradiology and has significantly benefited patients. Painful, obstructing ureteral stones can be…”
    Get full text
    Journal Article
  19. 19

    Optimization of thoracic spiral CT: effects of iodinated contrast medium concentration by Rubin, G D, Lane, M J, Bloch, D A, Leung, A N, Stark, P

    Published in Radiology (01-12-1996)
    “…To determine the effect of varying iodine concentration on arterial enhancement and perivenous artifact during thoracic spiral computed tomographic (CT)…”
    Get more information
    Journal Article
  20. 20

    Prediction of aortoiliac stent-graft length: comparison of measurement methods by Tillich, M, Hill, B B, Paik, D S, Petz, K, Napel, S, Zarins, C K, Rubin, G D

    Published in Radiology (01-08-2001)
    “…To determine the accuracy of helical computed tomography (CT), projectional angiography derived from CT angiography, and intravascular ultrasonographic…”
    Get more information
    Journal Article