Search Results - "Rovang, D."

Refine Results
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6

    Symmetric inertial-confinement-fusion-capsule implosions in a double-z-pinch-driven hohlraum by Bennett, G R, Cuneo, M E, Vesey, R A, Porter, J L, Adams, R G, Aragon, R A, Caird, J A, Landen, O L, Rambo, P K, Rovang, D C, Ruggles, L E, Simpson, W W, Smith, I C, Wenger, D F

    Published in Physical review letters (09-12-2002)
    “…An inertial-confinement-fusion (ICF) concept using two 60-MA Z pinches to drive a cylindrical hohlraum to 220 eV has been recently proposed. The first capsule…”
    Get full text
    Journal Article
  7. 7
  8. 8

    Time-Resolved Spot Size Measurements From Various Radiographic Diodes on the RITS-3 Accelerator by Portillo, S., Lutz, S.S., Mix, L.P., Hahn, K., Rovang, D., Maenchen, J.E., Molina, I., Cordova, S., Droemer, D., Chavez, R., Ziska, D.

    Published in IEEE transactions on plasma science (01-10-2006)
    “…Sandia National Laboratories is leading an intensive research effort into fielding and diagnosing electron-beam flash radiographic X-ray sources. Several X-ray…”
    Get full text
    Journal Article Conference Proceeding
  9. 9

    Multi-pulse electron diode development for flash radiography by Mazarakis, M., Cuneo, M., Hess, M., Kiefer, M., Leckbee, J., McKee, R., Rovang, D.

    Published in 2015 IEEE Pulsed Power Conference (PPC) (01-05-2015)
    “…Presently the Self Magnetic Pinch (SMP) diode is successfully utilized for flash radiography with pulsed power drivers. However, it is not capable of more than…”
    Get full text
    Conference Proceeding
  10. 10

    Cerebral vasculitis associated with acute post-streptococcal glomerulonephritis by Rovang, R D, Zawada, Jr, E T, Santella, R N, Jaqua, R A, Boice, J L, Welter, R L

    Published in American journal of nephrology (1997)
    “…The following is a case study involving a 13-year-old girl who presented initial symptoms of an upper respiratory infection. One week later she experienced a…”
    Get more information
    Journal Article
  11. 11

    Design of a large-bore 60-T pulse magnet for Sandia National Laboratories by Li, L., Rovang, D., Lesch, B., Pernambuco-Wise, P., Schneider-Muntau, H.J.

    “…The design of a new pulsed magnet system for the generation of intense electron beams is presented. Determined by the required magnetic field profile along the…”
    Get full text
    Journal Article Conference Proceeding
  12. 12
  13. 13

    Three-dimensional PIC simulations and analysis of the operating characteristics of the three cell RITS by Oliver, B.V., Clark, R.E., Johnson, D.L., Bailey, V., Corcoran, P., Smith, I., Maenchen, J.E., Molina, I., Rovang, D.C.

    “…Summary form only given. The Radiographic Integrated Test Stand (RITS) is the next generation, inductive voltage adder accelerator being developed at Sandia…”
    Get full text
    Conference Proceeding
  14. 14

    Pencil-like mm-size electron beams produced with linear inductive voltage adders by Mazarakis, M. G., Poukey, J. W., Rovang, D. C., Maenchen, J. E., Cordova, S. R., Menge, P. R., Pepping, R., Bennett, L., Mikkelson, K., Smith, D. L., Halbleib, J., Stygar, W. A., Welch, D. R.

    Published in Applied physics letters (17-02-1997)
    “…We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories…”
    Get full text
    Journal Article
  15. 15

    When reason reigns: madness, passion and sovereignty in late 18th-century England by Rovang, Dana

    Published in History of psychiatry (01-03-2006)
    “…In 1788–89, King George III of Great Britain became physically and mentally ill. This has been well documented, in contrast to the sudden influx of mentally…”
    Get full text
    Journal Article
  16. 16
  17. 17

    Increasing Load Current in Magnetized Liner Inertial Fusion Experiments by Gomez, M. R., Hutsel, B. T., Jennings, C. A., Martin, M. R., Cuneo, M. E., Hess, M. H., Laity, G. R., Lamppa, D. C., Peterson, K. J., Rochau, G. A., Rovang, D. C., Sinars, D. B., Slutz, S. A., Stygar, W. A.

    “…Magnetized Liner Inertial Fusion is a magneto-inertial fusion concept in which a metal cylindrical shell containing deuterium gas is axially magnetized, the…”
    Get full text
    Conference Proceeding
  18. 18

    Design and optimization of MAPS experiments on Sandia's Z machine by Haill, T. A., Alexander, C. S., Dalton, D. G., Rovang, D. C., Lamppa, D. C.

    “…Summary form only given. Magnetically-applied pressure-shear (MAPS) is a recently developed technique to directly measure material shear strength using…”
    Get full text
    Conference Proceeding
  19. 19

    Development of a dynamic spot size diagnostic for flash radiographic X-ray sources by Lutz, S., Droemer, D., Devore, D., Rovang, D., Portillo, S., Maenchen, J.

    “…There has been considerable work in recent years in the development of high-brightness, high-dose flash X-ray radiographic sources. Spot size is one of several…”
    Get full text
    Conference Proceeding
  20. 20

    Design of a high impedance MITL for RITS-3 by Bailey, V.L., Johnson, L., Corcoran, P., Smith, I., Maenchen, J.E., Molina, I., Hahn, K., Rovang, D., Portillo, S., Oliver, B.V., Rose, D., Welsh, D., Droemer, D., Guy, T.

    “…RITS-3 is the three-cell, 4 MV, 156 kA, 70 ns embodiment of the full twelve-cell 16 MV Radiographic Integrated Test Stand (RITS) (Ian D. Smith et al., 2000)…”
    Get full text
    Conference Proceeding